Controlling Flow of Power in Meshed Networks
Controlling Flow of Power in Meshed Networks
Expansion set for power flow control: students inject additional voltages using in-phase, quadrature and oblique regulation, thereby shifting real and reactive power between parallel lines.
- Comparing regulated and unregulated infeed
- Investigating in-phase regulation
- Investigating oblique regulation
- Observing and evaluating power flows
- Targeted power flow control
- Comparison of unregulated and regulated operation
- In-phase, quadrature and oblique regulation
- Digital grid visualization
In meshed networks, current flows are distributed according to the impedances of the lines. Without intervention, some paths are overloaded while others have spare capacity. Regulating transformers therefore inject an additional voltage to shift the power flow in a targeted way. This expansion set replicates two parallel 380 kV line paths and feeds them via a three-phase transformer with 400 V and 30 V windings. Students first compare the unregulated case with the regulated case. They then investigate in-phase, quadrature and oblique regulation and measure how the magnitude and phase angle of the additional voltage affect the load current. SCADA for PowerLab records the power flows in both circuits, so that phasor calculations can be checked directly.
| Base Product | |
| CO3301-3N | Isolating transformer, Three-phase, 1kW |
| CO3301-3M | Conversion station 380 V/110 V |
| CO3301-3A | Transmission line Model 150km/300km (93.2miles/186.4miles) |
| SO2800-3L | Interactive Lab Assistant: High-voltage transmission lines |
| CO3301-3F | Variable Ohmic load, three-phase, 1kW |
| CO3301-3E | Capacitive load, three-phase, 1kW |
| CO3301-3D | Inductive load, three-phase, 1kW |
| CO3301-5P | Power switch module |
| Software | |
| SO4001-3H | Software SCADA Viewer |
| Measuring Instruments | |
| CO5127-2S | Power Quality Meter mit Grafikdisplay und Langzeitspeicher |
| CO3301-3Z | Adjustable 3-phase power supply, 0-450V/2A |
| Accessories | |
| LM9057 | Patch cable Cat5E 1x 1m yellow, 2x 2m yellow |
| LM8257 | USB 2.0 Ethernet adapter, 10/100 |
| LM9988 | 5-Port Ethernet Switch |
| ST8010-4J | Multiple socket outlet, 6 fold, with illuminated switch |
| Furniture | |
| ST7200-7A | SybaPro experiment trolley, 3-level, 6 sockets, 1250x1970x800mm |
| ST8010-4T | Monitor holder for flat screen monitor of weight up to 15kg / 33lbs |
| ST7200-5L | Protection cover for three-level experiment trolleys |
| ST8010-4G | Keyboard adapter for flat screen monitor holders |
| Furniture Accessories | |
| ST8000-4L | Display for Power Transmission equipment |
| Measurement Leads | |
| SO5126-3R | Safety connecting plug 4mm with tap (2x), black, 1000V/32A CAT II |
| SO5126-3V | Safety connecting plug 4mm with tap (2x), blue, 1000V/32A CAT II |
| SO5126-3W | Safety connecting plug 4mm with tap (2x), green/yellow, 1000V/32A CAT II |
| SO5148-1L | Set of safety measurement cables, 4mm (31 leads) |
| SO5126-8B | Safety measurement cable 4mm, 25cm/10", black, 600V CAT III ~1000V CAT II / 32A |
| SO5126-8L | Safety measurement cable 4mm, 50cm/20", black, 600V CAT III ~1000V CAT II / 32A |
Learning Content in Detail
Comparing regulated and unregulated infeed
Investigating in-phase regulation
Investigating oblique regulation
Observing and evaluating power flows
Comparing theory and practice
Features & Applications
- Targeted power flow control — Real and reactive power flows in meshed three-phase networks can be specifically controlled and redirected.
- Comparison of unregulated and regulated operation — Students compare the load distribution with an unregulated and a regulated transformer side by side.
- In-phase, quadrature and oblique regulation — Students investigate how the magnitude and phase angle of the additional voltage change the load current of parallel lines.
- Digital grid visualization — SCADA for PowerLab records all voltage and current vectors on the transmission lines in real time.
- Isolation transformer, three-phase, 1 kW (CO3301-3N) — The transformer feeds the line model. It has windings for 3 x 400 V and 3 x 30 V in vector group Dyn5.
- Line models (CO3301-3A) — Two three-phase 380 kV overhead line modules represent the parallel paths in the meshed transmission grid.
- Power Quality Meter (CO5127-1S) — The meters record real, reactive and apparent power as well as phase angles at the feed and load nodes and output them via Ethernet.
- Transformer substation 380 V/110 V (CO3301-3M) — The 400 VA three-phase transformer with vector group YNyn0 couples the two voltage levels in the interconnected grid.
- SCADA for PowerLab software — The software displays the meshed network in a digital system diagram, for example as EUL7.pvc, and records the power flows live.

From Knowledge Comes Capability.
You guide the learning
Where theory and practice go hand in hand.
RXLea brings a new way of learning: project-based, hands-on and clearly structured. Learners solve real-world tasks, while instructors save time on preparation. Interactive modules, smart analytics and real hardware create a modern, efficient learning world.
Hands-on and interactive
Animations, interactive tasks and realistic scenarios build a deep understanding. All content is organized into clear learning paths for focused, hands-on learning.
Digital support
3D assembly animations and digital instructions simplify complex procedures, reduce errors and help learners work more independently.
Visual support
Overview graphics, screenshots and sample animations make the learning world transparent. Photos from the learning packages are also available, including country-specific versions where needed.




Stay ahead in
technical training.
Get the latest training systems, product launches and educational insights, delivered directly to your inbox.