EUL41PT

Equipment set with a 1 kW synchronous machine and servo machine test bench. Students synchronize the generator to the infinite bus and control real and reactive power independently of each other.

Learning Content
  • Safely connecting the generator to the grid
  • Analyzing voltage behavior during load changes
  • Controlling real power
  • Controlling reactive power
KEY FEATURES
  • Safe grid synchronization
  • Active control of real and reactive power
  • Realistic machine set
  • Automated experiment evaluation
Speak with a Product Specialist +1 (757) 808-5696 · sales@lucas-nuelle.com

Connecting a generator to the grid and controlling the power it feeds in is one of the core tasks of power generation. In a real plant, errors during connection have serious consequences. This expansion set replicates a power plant in the lab: a 1 kW three-phase synchronous machine with a non-salient pole rotor, a servo machine test bench acting as the driving turbine, an excitation voltage controller and a synchronizing unit with a digital synchroscope. Students check the phase sequence and phase coincidence, connect the generator to the grid and observe the power distribution in the network. They control the real power via the torque of the drive machine and the reactive power via the excitation voltage. SCADA for PowerLab and ActiveServo record the grid parameters in real time.

SE2682-5QThree-phase synchronous machine with smooth core rotor, 1kW
CO3301-5GExciter voltage controller with de-excitation
CO3212-6VSynchronization Unit
CO3301-3ATransmission line Model 150km/300km (93.2miles/186.4miles)
SO2800-3LInteractive Lab Assistant: High-voltage transmission lines
CO3301-3FVariable Ohmic load, three-phase, 1kW
CO3301-3ECapacitive load, three-phase, 1kW
CO3301-3DInductive load, three-phase, 1kW
CO3301-5PPower switch module
SO4001-3HSoftware SCADA Viewer
CO5127-2SPower Quality Meter mit Grafikdisplay und Langzeitspeicher
CO3301-3ZAdjustable 3-phase power supply, 0-450V/2A
LM9057Patch cable Cat5E 1x 1m yellow, 2x 2m yellow
LM8257USB 2.0 Ethernet adapter, 10/100
LM99885-Port Ethernet Switch
ST8010-4JMultiple socket outlet, 6 fold, with illuminated switch
CO3636-6YServo machine test stand for 1kW machines incl. software ActiveServo (D,GB,F,E)
SE2662-7DCoupling guard with LED lighting for 1kW machines
SE2662-6ARubber coupling sleeve, 1kW
ST7200-7ASybaPro experiment trolley, 3-level, 6 sockets, 1250x1970x800mm
ST8010-4TMonitor holder for flat screen monitor of weight up to 15kg / 33lbs
ST7200-5LProtection cover for three-level experiment trolleys
ST8010-4GKeyboard adapter for flat screen monitor holders
ST8008-8NProtected power distribution for working stations
ST8010-4JMultiple socket outlet, 6 fold, with illuminated switch
ST8000-4LDisplay for Power Transmission equipment
SO5126-3RSafety connecting plug 4mm with tap (2x), black, 1000V/32A CAT II
SO5126-3VSafety connecting plug 4mm with tap (2x), blue, 1000V/32A CAT II
SO5126-3WSafety connecting plug 4mm with tap (2x), green/yellow, 1000V/32A CAT II
SO5148-1LSet of safety measurement cables, 4mm (31 leads)
SO5126-8BSafety measurement cable 4mm, 25cm/10", black, 600V CAT III ~1000V CAT II / 32A
SO5126-8LSafety measurement cable 4mm, 50cm/20", black, 600V CAT III ~1000V CAT II / 32A

Learning Content in Detail

Students work through the process from connecting the generator to the grid to specifically controlling the power it feeds in, and relate each control action to its effect.

Safely connecting the generator to the grid

Students check the phase sequence and phase coincidence and carry out the synchronization correctly.

Analyzing voltage behavior during load changes

Students investigate how the voltage changes when loads are connected and disconnected.

Controlling real power

Students control the torque of the drive machine and thereby the real power fed into the grid.

Controlling reactive power

Students vary the excitation voltage and record the resulting reactive power infeed.

Features & Applications

The experiments follow the tasks in power plant and grid operation: power and current distribution in generator-fed line networks, synchronization and parallel operation, and control of real and reactive power infeed.
  • Safe grid synchronization — The setup includes a digital synchroscope and a double frequency meter. With these, students connect the generator to the infinite bus without errors.
  • Active control of real and reactive power — Students control the real power via the servo machine test bench and the reactive power via the excitation voltage controller. Both variables can be observed separately.
  • Realistic machine set — A 1 kW three-phase synchronous machine with a non-salient pole rotor and the industrial servo test bench replicate the power plant.
  • Automated experiment evaluation — SCADA for PowerLab and the ActiveServo software record the measured values, control the test bench and support analysis on the PC.
  • Synchronizing unit (CO3212-6V) — This compact module for the dark-lamp method contains a synchronization indicator, zero voltmeter, double frequency meter and digital synchroscope.
  • Excitation voltage controller (CO3301-5G) — It supplies a precise DC voltage of up to 200 V DC. A de-excitation switch protects the generator in the event of a fault.
  • Servo machine test bench (CO3636-6Y) — This highly dynamic drive and brake system operates in four-quadrant mode and comes with 10 selectable driven machine models.
  • Three-phase synchronous machine 1 kW (SE2682-5Q) — This industrial non-salient pole machine behaves like a real machine on the grid. An electronic nameplate provides the machine data.
  • Three-phase line module (CO3301-3A) — The module contains lumped elements for resistance, inductance, and line-to-line and line-to-ground capacitance.
  • Load modules up to 1 kW — Three separate modules for resistive, inductive and capacitive loads allow wye, delta, series and parallel connections.
  • Power Quality Meter (CO5127-1S) — The Ethernet-enabled meter records currents, voltages, line harmonics and distortion factors and shows them on a large graphic display.
  • SCADA for PowerLab software — The software shows power flows and currents during grid synchronization and parallel operation in a digital system diagram.
  • ActiveServo software — Using the software, students control the servo test bench and precisely regulate the mechanical drive torque of the generator.
Learners working with RXLea on a tablet at a Lucas-Nuelle training system
RXLea

From Knowledge Comes Capability.

You guide the learning

Where theory and practice go hand in hand.

RXLea brings a new way of learning: project-based, hands-on and clearly structured. Learners solve real-world tasks, while instructors save time on preparation. Interactive modules, smart analytics and real hardware create a modern, efficient learning world.

Hands-on and interactive

Animations, interactive tasks and realistic scenarios build a deep understanding. All content is organized into clear learning paths for focused, hands-on learning.

Digital support

3D assembly animations and digital instructions simplify complex procedures, reduce errors and help learners work more independently.

Visual support

Overview graphics, screenshots and sample animations make the learning world transparent. Photos from the learning packages are also available, including country-specific versions where needed.

Learners using a tablet at an energy training system
RXLea on desktop, laptop and tablet
RXLea Path Creator for building learning journeys
RXLea Navigator showing the learning world
Learn more about RXLea
Newsletter

Stay ahead in
technical training.

Get the latest training systems, product launches and educational insights, delivered directly to your inbox.

Your email address

By subscribing, you agree to our Privacy Policy. You can unsubscribe at any time.

 Please select at least one category before subscribing.
I'm interested in - select all that apply