Skip to content

Parallel and series connection of transmission lines

RXLea
Digital projects for hands-on learningInteractive learning content, directly connected to the training system.

Parallel and series connection of transmission lines

EUL21PT

Expansion set for meshed networks: students measure the current, voltage and power distribution on three-phase lines from 150 km to 600 km connected in parallel and in series.

Learning Content
  • Measuring current distribution in parallel connection
  • Analyzing asymmetrical load distribution
  • Determining voltage drop in series connection
  • Evaluating power flow in the interconnected grid
KEY FEATURES
  • Investigating parallel connections
  • Analyzing series connections
  • Flexibly combinable line lengths
  • Integrated SCADA data acquisition
Speak with a Product Specialist +1 (757) 808-5696 · sales@lucas-nuelle.com

In interconnected grids, transmission lines are often run in parallel or in series in order to transmit high power. How current and power are shared depends on the impedances of the individual line sections. This expansion set couples two line models to replicate line sections from 150 km to 600 km. Students connect lines of equal and different lengths in parallel, measure the currents on both paths and compare them. In the series connection, they determine the total voltage drop. Power Quality Meters record the grid parameters at several nodes, and SCADA for PowerLab displays them. Finally, students evaluate the influence of the line impedances on the load flow and check their calculations against the measured values.

CO3301-3ATransmission line Model 150km/300km (93.2miles/186.4miles)
CO5127-2APower-Multimeter
CO3301-3ATransmission line Model 150km/300km (93.2miles/186.4miles)
SO2800-3LInteractive Lab Assistant: High-voltage transmission lines
CO3301-3FVariable Ohmic load, three-phase, 1kW
CO3301-3ECapacitive load, three-phase, 1kW
CO3301-3DInductive load, three-phase, 1kW
CO3301-5PPower switch module
SO4001-3HSoftware SCADA Viewer
CO5127-2SPower Quality Meter mit Grafikdisplay und Langzeitspeicher
CO3301-3ZAdjustable 3-phase power supply, 0-450V/2A
LM9057Patch cable Cat5E 1x 1m yellow, 2x 2m yellow
LM8257USB 2.0 Ethernet adapter, 10/100
LM99885-Port Ethernet Switch
ST8010-4JMultiple socket outlet, 6 fold, with illuminated switch
ST7200-7ASybaPro experiment trolley, 3-level, 6 sockets, 1250x1970x800mm
ST8010-4TMonitor holder for flat screen monitor of weight up to 15kg / 33lbs
ST7200-5LProtection cover for three-level experiment trolleys
ST8010-4GKeyboard adapter for flat screen monitor holders
ST8000-4LDisplay for Power Transmission equipment
SO5126-3RSafety connecting plug 4mm with tap (2x), black, 1000V/32A CAT II
SO5126-3VSafety connecting plug 4mm with tap (2x), blue, 1000V/32A CAT II
SO5126-3WSafety connecting plug 4mm with tap (2x), green/yellow, 1000V/32A CAT II
SO5148-1LSet of safety measurement cables, 4mm (31 leads)
SO5126-8BSafety measurement cable 4mm, 25cm/10", black, 600V CAT III ~1000V CAT II / 32A
SO5126-8LSafety measurement cable 4mm, 50cm/20", black, 600V CAT III ~1000V CAT II / 32A

Learning Content in Detail

Students learn how currents and power are distributed across several transmission lines and compare their calculations with the measured values.

Measuring current distribution in parallel connection

Students compare the currents on parallel lines of equal length.

Analyzing asymmetrical load distribution

Students investigate the power distribution on parallel lines of different lengths.

Determining voltage drop in series connection

Students determine the total voltage drop across line sections connected in series.

Evaluating power flow in the interconnected grid

Students assess how the line impedances determine the resulting power flow.

Comparing theory and measurement

Students compare their calculations with the measurement results and evaluate the deviations.

Features & Applications

The experiments address the key issues of meshed networks: power and current distribution in meshed and interconnected grids, parallel operation of overhead lines of different lengths, and voltage drop in series connection.
  • Investigating parallel connections — Students determine the current and power distribution on parallel lines of equal and different lengths, i.e. 150 km and 300 km.
  • Analyzing series connections — With line sections connected in series, students systematically measure the operating behavior and the voltage drop.
  • Flexibly combinable line lengths — By combining two line models, transmission lines from 150 km to 600 km can be set up.
  • Integrated SCADA data acquisition — Power Quality Meters record the grid parameters at various line nodes in real time and pass them on to the PC for visualization.
  • Line model 150 km/300 km (CO3301-3A) — This three-phase model of a 380 kV overhead line switches the line length automatically using overlay masks.
  • Power Quality Meter (CO5127-1S) — The digital three-phase meter records voltages, currents and real, reactive and apparent power and outputs them via Ethernet.
  • Load modules up to 1 kW — Three separate modules for resistive, inductive and capacitive loads allow wye, delta, series and parallel connections.
  • Circuit breaker module (CO3301-5P) — It switches the 400 V supply voltage on and off during the experiments, either manually or by electrical remote control.
  • SCADA for PowerLab — The software provides a clear real-time display of the power flows, voltages and currents in the parallel and series connections.
Learners working with RXLea on a tablet at a Lucas-Nuelle training system
RXLea

From Knowledge Comes Capability.

You guide the learning

Where theory and practice go hand in hand.

RXLea brings a new way of learning: project-based, hands-on and clearly structured. Learners solve real-world tasks, while instructors save time on preparation. Interactive modules, smart analytics and real hardware create a modern, efficient learning world.

Hands-on and interactive

Animations, interactive tasks and realistic scenarios build a deep understanding. All content is organized into clear learning paths for focused, hands-on learning.

Digital support

3D assembly animations and digital instructions simplify complex procedures, reduce errors and help learners work more independently.

Visual support

Overview graphics, screenshots and sample animations make the learning world transparent. Photos from the learning packages are also available, including country-specific versions where needed.

Learners using a tablet at an energy training system
RXLea on desktop, laptop and tablet
RXLea Path Creator for building learning journeys
RXLea Navigator showing the learning world
Learn more about RXLea
Newsletter

Stay ahead in
technical training.

Get the latest training systems, product launches and educational insights, delivered directly to your inbox.

Your email address

By subscribing, you agree to our Privacy Policy. You can unsubscribe at any time.

 Please select at least one category before subscribing.