Learning Content
  • Understanding the protection requirements of parallel lines
  • Defining protection direction and pick-up values
  • Creating a time coordination plan
  • Checking the selectivity of the protection system
KEY FEATURES
  • Selectivity through combined protection concepts
  • Investigating the (n-1) criterion in practice
  • Parameterization via SCADA or by hand
  • Tuning time coordination in the grid
Speak with a Product Specialist +1 (757) 808-5696 · sales@lucas-nuelle.com

In meshed networks and with parallel lines, simple time-overcurrent protection is not sufficient to locate the fault. Only the additional evaluation of the power flow direction keeps the healthy line in operation and satisfies the (n-1) criterion. For this purpose, the equipment set combines time-overcurrent relays at the sending end of the line with directional relays at the receiving end. Students set up the parallel transmission line from two line models, define the protection direction and pick-up values and coordinate the tripping delays into a time coordination plan. They then apply short circuits at various points and check whether only the affected section is disconnected.

Artikel-Nr.MengeBezeichnung
CO3301-4J2Überstromzeitrelais
CO3301-4D2Time Overcurrent Relay with directional feature
CO3301-3A2Transmission line Model 150km/300km (93.2miles/186.4miles)
CO3301-5P5Power switch module
CO3301-3F1Variable Ohmic load, three-phase, 1kW
SO2800-6L1Interactive Lab Assistant: Protective systems for high-voltage transmission line
SO4001-3H1Software SCADA Viewer
CO3301-3Z1Adjustable 3-phase power supply, 0-450V/2A
CO5127-2S1Power Quality Meter mit Grafikdisplay und Langzeitspeicher
LM23301Multi13S digital multimeter
LM90571Patch cable Cat5E 1x 1m yellow, 2x 2m yellow
LM82571USB 2.0 Ethernet adapter, 10/100
LM998815-Port Ethernet Switch
ST8010-4J2Multiple socket outlet, 6 fold, with illuminated switch
LM90251Interface converter USB/RS485
ST7200-7A1SybaPro experiment trolley, 3-level, 6 sockets, 1250x1970x800mm
ST8010-4T1Monitor holder for flat screen monitor of weight up to 15kg / 33lbs
ST7200-5L1Protection cover for three-level experiment trolleys
ST8010-4G1Keyboard adapter for flat screen monitor holders
ST8000-4L1Display for Power Transmission equipment
SO5126-3R40Safety connecting plug 4mm with tap (2x), black, 1000V/32A CAT II
SO5126-3V10Safety connecting plug 4mm with tap (2x), blue, 1000V/32A CAT II
SO5126-3W10Safety connecting plug 4mm with tap (2x), green/yellow, 1000V/32A CAT II
SO5148-1L1Set of safety measurement cables, 4mm (31 leads)

Learning Content in Detail

Students explore the protection requirements for parallel lines, set the relays and verify selectivity in the event of a short circuit.

Understanding the protection requirements of parallel lines

Students examine the structure of parallel lines and meshed networks and the resulting protection requirements.

Defining protection direction and pick-up values

Students define the protection direction and determine the minimum pick-up values of the relays.

Creating a time coordination plan

Students create a time coordination plan and set the corresponding tripping delays.

Checking the selectivity of the protection system

Students check the interaction of overcurrent and directional measurement in the event of a short circuit.

Features & Applications

The experiments address the protection of parallel lines and ring networks at high-voltage and extra-high-voltage levels, as well as selective fault clearance in meshed networks according to the (n-1) criterion.
  • Selectivity through combined protection concepts — Non-directional and directional time-overcurrent relays work together. This allows faults in the ring network to be located and selectively disconnected.
  • Investigating the (n-1) criterion in practice — Students check whether the failure of one line interrupts normal operation and use this to assess security of supply.
  • Parameterization via SCADA or by hand — The relays can be set using the front panel controls or on the PC via the integrated RS485 interface.
  • Tuning time coordination in the grid — Tripping delays and tripping directions are set individually and combined into a consistent time coordination plan.
  • Time-overcurrent relay (CO3301-4J) — This three-phase relay detects overloads and short circuits at the sending end of the line.
  • Directional time-overcurrent relay (CO3301-4D) — This digital relay detects the power flow direction and selectively protects the receiving end of the line.
  • Line models 150 km / 300 km (CO3301-3A) — Two three-phase models of high-voltage overhead lines form the parallel transmission lines.
  • Circuit breaker module (CO3301-5P) — The module applies and removes faults manually or by remote control. Indicator lamps show the operating status.
  • Variable three-phase power supply 0–450 V / 2 A (CO3301-3Z) — This infinitely variable power supply with variable transformer feeds the line network.
  • SCADA Viewer — The software controls and parameterizes the networked protective relays and monitors the line states in real time.
Learners working with RXLea on a tablet at a Lucas-Nuelle training system
RXLea

From Knowledge Comes Capability.

You guide the learning

Where theory and practice go hand in hand.

RXLea brings a new way of learning: project-based, hands-on and clearly structured. Learners solve real-world tasks, while instructors save time on preparation. Interactive modules, smart analytics and real hardware create a modern, efficient learning world.

Hands-on and interactive

Animations, interactive tasks and realistic scenarios build a deep understanding. All content is organized into clear learning paths for focused, hands-on learning.

Digital support

3D assembly animations and digital instructions simplify complex procedures, reduce errors and help learners work more independently.

Visual support

Overview graphics, screenshots and sample animations make the learning world transparent. Photos from the learning packages are also available, including country-specific versions where needed.

Learners using a tablet at an energy training system
RXLea on desktop, laptop and tablet
RXLea Path Creator for building learning journeys
RXLea Navigator showing the learning world
Learn more about RXLea
Newsletter

Stay ahead in
technical training.

Get the latest training systems, product launches and educational insights, delivered directly to your inbox.

Your email address

By subscribing, you agree to our Privacy Policy. You can unsubscribe at any time.

 Please select at least one category before subscribing.
I'm interested in - select all that apply