Combined Networks of Cables and Lines
Combined Networks of Cables and Lines
Expansion set for mixed transmission lines: students measure the power flow and losses of an overhead line, transformer substation and underground cable, both individually and combined.
- Comparing cables and overhead lines
- Investigating transmission line 1
- Investigating transmission line 2
- Determining losses in the interconnected grid
- Investigating combined transmission lines
- Determining the losses of individual grid components
- Interface analysis via transformer substations
- Measurement at several nodes
Real transmission grids rarely consist of a single medium. Overhead lines, transformer substations and underground cables are arranged in series, and each element behaves differently. This expansion set combines a 380 kV overhead line model, a 380 V/110 V transformer substation and a cable model into one continuous transmission line. Students set up the sequence of overhead line, transformer and cable, then reverse it and compare the two cases. Power Quality Meters at the transfer points provide the measured values from which students determine the individual losses of each component. They determine the efficiency and operating behavior of the transformer substation under load and check their model calculations against the measurement results.
| Base Product | |
| CO3301-3C | Kabelnachbildung 12,5 km / 37,5 km |
| CO3301-3M | Conversion station 380 V/110 V |
| CO3301-3A | Transmission line Model 150km/300km (93.2miles/186.4miles) |
| SO2800-3L | Interactive Lab Assistant: High-voltage transmission lines |
| CO3301-3F | Variable Ohmic load, three-phase, 1kW |
| CO3301-3E | Capacitive load, three-phase, 1kW |
| CO3301-3D | Inductive load, three-phase, 1kW |
| CO3301-5P | Power switch module |
| Software | |
| SO4001-3H | Software SCADA Viewer |
| Measuring Instruments | |
| CO5127-2S | Power Quality Meter mit Grafikdisplay und Langzeitspeicher |
| CO3301-3Z | Adjustable 3-phase power supply, 0-450V/2A |
| Accessories | |
| LM9057 | Patch cable Cat5E 1x 1m yellow, 2x 2m yellow |
| LM8257 | USB 2.0 Ethernet adapter, 10/100 |
| LM9988 | 5-Port Ethernet Switch |
| ST8010-4J | Multiple socket outlet, 6 fold, with illuminated switch |
| Furniture | |
| ST7200-7A | SybaPro experiment trolley, 3-level, 6 sockets, 1250x1970x800mm |
| ST8010-4T | Monitor holder for flat screen monitor of weight up to 15kg / 33lbs |
| ST7200-5L | Protection cover for three-level experiment trolleys |
| ST8010-4G | Keyboard adapter for flat screen monitor holders |
| Furniture Accessories | |
| ST8000-4L | Display for Power Transmission equipment |
| Measurement Leads | |
| SO5126-3R | Safety connecting plug 4mm with tap (2x), black, 1000V/32A CAT II |
| SO5126-3V | Safety connecting plug 4mm with tap (2x), blue, 1000V/32A CAT II |
| SO5126-3W | Safety connecting plug 4mm with tap (2x), green/yellow, 1000V/32A CAT II |
| SO5148-1L | Set of safety measurement cables, 4mm (31 leads) |
| SO5126-8B | Safety measurement cable 4mm, 25cm/10", black, 600V CAT III ~1000V CAT II / 32A |
| SO5126-8L | Safety measurement cable 4mm, 50cm/20", black, 600V CAT III ~1000V CAT II / 32A |
Learning Content in Detail
Comparing cables and overhead lines
Investigating transmission line 1
Investigating transmission line 2
Determining losses in the interconnected grid
Determining the parameters of the transformer substation
Features & Applications
- Investigating combined transmission lines — Students analyze grid structures consisting of overhead lines, transformers and underground cables as a whole.
- Determining the losses of individual grid components — Real power and power losses can be determined separately for overhead line sections, transformer substations and cable sections.
- Interface analysis via transformer substations — The transformation from 380 V to 110 V realistically replicates the transfer point between overhead line and underground cable.
- Measurement at several nodes — Several Power Quality Meters simultaneously record the electrical parameters at the transfer points of the interconnected grid.
- Cable model (CO3301-3C) — This three-phase underground cable model with values for 12.5 km and 37.5 km represents the cable section of the grid.
- Transformer substation 380 V/110 V (CO3301-3M) — The 400 VA three-phase transformer with vector group YNyn0 couples the two voltage levels in the interconnected grid.
- Power Quality Meter (CO5127-1S) — The meters record currents, voltages and power at several points along the combined transmission line.
- Line model (CO3301-3A) — The model of a 380 kV line represents the overhead line section of the transmission line.
- SCADA for PowerLab software — The software displays the interconnected grid topologies, for example as diagram EUL_6.pvc, and logs the measured values of all system nodes.

From Knowledge Comes Capability.
You guide the learning
Where theory and practice go hand in hand.
RXLea brings a new way of learning: project-based, hands-on and clearly structured. Learners solve real-world tasks, while instructors save time on preparation. Interactive modules, smart analytics and real hardware create a modern, efficient learning world.
Hands-on and interactive
Animations, interactive tasks and realistic scenarios build a deep understanding. All content is organized into clear learning paths for focused, hands-on learning.
Digital support
3D assembly animations and digital instructions simplify complex procedures, reduce errors and help learners work more independently.
Visual support
Overview graphics, screenshots and sample animations make the learning world transparent. Photos from the learning packages are also available, including country-specific versions where needed.




Stay ahead in
technical training.
Get the latest training systems, product launches and educational insights, delivered directly to your inbox.