Load-Dependent Voltage Regulation of a Power Transmission Line
Load-Dependent Voltage Regulation of a Power Transmission Line
Expansion set for load-dependent voltage control: students control a motor-driven three-phase variable transformer manually and automatically via SCADA and the Power Quality Meter.
- Investigating how the VRDT works
- Determining no-load and short-circuit behavior
- Analyzing the voltage profile along the line
- Setting the voltage manually
- Voltage-regulated distribution transformer (VRDT)
- Motor-driven variable transformer
- Manual and automatic control
- Integrated smart grid control
Distributed infeed from photovoltaics causes voltage fluctuations in low-voltage grids. Voltage-regulated distribution transformers compensate for this by adjusting their transformation ratio to the load conditions. This expansion set combines a motor-driven three-phase variable transformer in autotransformer connection with a line model, loads and a Power Quality Meter. Students first investigate the control range and the no-load and short-circuit behavior of the autotransformer. They then connect loads and observe the voltage drop along the line. First they readjust the voltage manually using pushbuttons, then they set up automatic control: the Power Quality Meter records the actual value and sends the raise and lower commands to the motor drive.
| Base Product | |
| CO3301-3A | Transmission line Model 150km/300km (93.2miles/186.4miles) |
| CO3301-3P | Three-phase variable transformer with motor drive |
| CO3301-3F | Variable Ohmic load, three-phase, 1kW |
| CO3301-3D | Inductive load, three-phase, 1kW |
| CO3301-5P | Power switch module |
| SO2800-3L | Interactive Lab Assistant: High-voltage transmission lines |
| Software | |
| SO4001-3H | Software SCADA Viewer |
| Measuring Instruments | |
| CO5127-2S | Power Quality Meter mit Grafikdisplay und Langzeitspeicher |
| CO3301-3Z | Adjustable 3-phase power supply, 0-450V/2A |
| Accessories | |
| LM9057 | Patch cable Cat5E 1x 1m yellow, 2x 2m yellow |
| LM8257 | USB 2.0 Ethernet adapter, 10/100 |
| LM9988 | 5-Port Ethernet Switch |
| ST8010-4J | Multiple socket outlet, 6 fold, with illuminated switch |
| Furniture | |
| ST7200-7A | SybaPro experiment trolley, 3-level, 6 sockets, 1250x1970x800mm |
| ST8010-4T | Monitor holder for flat screen monitor of weight up to 15kg / 33lbs |
| ST7200-5L | Protection cover for three-level experiment trolleys |
| ST8010-4G | Keyboard adapter for flat screen monitor holders |
| Furniture Accessories | |
| ST8000-4L | Display for Power Transmission equipment |
| Measurement Leads | |
| SO5126-3R | Safety connecting plug 4mm with tap (2x), black, 1000V/32A CAT II |
| SO5126-3V | Safety connecting plug 4mm with tap (2x), blue, 1000V/32A CAT II |
| SO5126-3W | Safety connecting plug 4mm with tap (2x), green/yellow, 1000V/32A CAT II |
| SO5148-1L | Set of safety measurement cables, 4mm (31 leads) |
| SO5126-8B | Safety measurement cable 4mm, 25cm/10", black, 600V CAT III ~1000V CAT II / 32A |
| SO5126-8L | Safety measurement cable 4mm, 50cm/20", black, 600V CAT III ~1000V CAT II / 32A |
Learning Content in Detail
Investigating how the VRDT works
Determining no-load and short-circuit behavior
Analyzing the voltage profile along the line
Setting the voltage manually
Setting up automatic voltage control
Features & Applications
- Voltage-regulated distribution transformer (VRDT) — The system replicates the compensation of voltage fluctuations in the local distribution grid under changing infeed and load conditions.
- Motor-driven variable transformer — The variable transformer adjusts the voltage from 0 to 450 V via control inputs.
- Manual and automatic control — Students can either control the voltage by hand using pushbuttons or have it adjusted fully automatically via SCADA.
- Integrated smart grid control — The Power Quality Meter records the actual value and sends the raise and lower commands to the transformer’s motor drive.
- Three-phase variable transformer (CO3301-3P) — This variable transformer in autotransformer connection is rated at 1000 VA in vector group Yan0 and has 24 V inputs for raising and lowering the voltage.
- Line model 150 km/300 km (CO3301-3A) — This three-phase 380 kV overhead line model replicates the voltage drop along the line under load.
- Power Quality Meter (CO5127-1S) — The meter records the grid voltage at the end of the line and sends switching signals to the transformer’s motor control.
- Load modules up to 1 kW — Three separate modules for resistive, inductive and capacitive loads allow wye, delta, series and parallel connections.
- SCADA for PowerLab software — The software visualizes the voltage control in the digital circuit diagram and automatically controls the transformer within the specified setpoint range.

From Knowledge Comes Capability.
You guide the learning
Where theory and practice go hand in hand.
RXLea brings a new way of learning: project-based, hands-on and clearly structured. Learners solve real-world tasks, while instructors save time on preparation. Interactive modules, smart analytics and real hardware create a modern, efficient learning world.
Hands-on and interactive
Animations, interactive tasks and realistic scenarios build a deep understanding. All content is organized into clear learning paths for focused, hands-on learning.
Digital support
3D assembly animations and digital instructions simplify complex procedures, reduce errors and help learners work more independently.
Visual support
Overview graphics, screenshots and sample animations make the learning world transparent. Photos from the learning packages are also available, including country-specific versions where needed.




Stay ahead in
technical training.