Earth-Fault Voltage Protection
Earth-Fault Voltage Protection
Equipment set for digital ground-fault voltage protection: students measure the displacement voltage via the open-delta winding, apply specific ground faults and parameterize the protective relay.
- Measuring voltages during a ground fault
- Determining pick-up values and inherent operating time
- Testing tripping behavior
- Investigating neutral point displacement
- Detecting ground faults via the displacement voltage
- Parameterization via SCADA or by hand
- Realistic voltage transformation with tertiary winding
- Analyzing neutral point displacement in real time
In networks with an ungrounded or compensated neutral, the detection of ground faults is crucial for security of supply. The measurement criterion is the displacement voltage, which is taken from the open-delta winding of voltage transformers: when a ground fault occurs, the neutral point shifts, the displacement voltage rises and the relay trips. The equipment set replicates this chain with a set of instrument transformers, a line model and a circuit breaker. Students measure the voltages in the healthy network and in the network with a ground fault, apply specific ground faults and determine the pick-up and drop-off values and the inherent system operating time. The behavior during transient ground faults can also be tested in this way.
| Base Product | |
| CO3301-4K | Earth fault voltage Relay |
| CO3301-4V | Voltage transformer, 3 phase |
| CO3301-3A | Transmission line Model 150km/300km (93.2miles/186.4miles) |
| CO3301-3F | Variable Ohmic load, three-phase, 1kW |
| CO3301-5P | Power switch module |
| SO2800-6L | Interactive Lab Assistant: Protective systems for high-voltage transmission line |
| Software | |
| SO4001-3H | Software SCADA Viewer |
| Power Supply | |
| CO3301-3Z | Adjustable 3-phase power supply, 0-450V/2A |
| Measuring Instruments | |
| CO5127-2S | Power Quality Meter mit Grafikdisplay und Langzeitspeicher |
| LM2330 | Multi13S digital multimeter |
| Accessories | |
| LM9057 | Patch cable Cat5E 1x 1m yellow, 2x 2m yellow |
| LM8257 | USB 2.0 Ethernet adapter, 10/100 |
| LM9988 | 5-Port Ethernet Switch |
| ST8010-4J | Multiple socket outlet, 6 fold, with illuminated switch |
| LM9025 | Interface converter USB/RS485 |
| Furniture | |
| ST7200-7A | SybaPro experiment trolley, 3-level, 6 sockets, 1250x1970x800mm |
| ST8010-4T | Monitor holder for flat screen monitor of weight up to 15kg / 33lbs |
| ST7200-5L | Protection cover for three-level experiment trolleys |
| ST8010-4G | Keyboard adapter for flat screen monitor holders |
| Furniture Accessories | |
| ST8000-4L | Display for Power Transmission equipment |
| Measurement Leads | |
| SO5126-3R | Safety connecting plug 4mm with tap (2x), black, 1000V/32A CAT II |
| SO5126-3V | Safety connecting plug 4mm with tap (2x), blue, 1000V/32A CAT II |
| SO5126-3W | Safety connecting plug 4mm with tap (2x), green/yellow, 1000V/32A CAT II |
| SO5148-1L | Set of safety measurement cables, 4mm (31 leads) |
Learning Content in Detail
Measuring voltages during a ground fault
Determining pick-up values and inherent operating time
Testing tripping behavior
Investigating neutral point displacement
Features & Applications
- Detecting ground faults via the displacement voltage — The digital relay detects ground faults in ungrounded and semi-solidly grounded networks on the basis of the displacement voltage.
- Parameterization via SCADA or by hand — The relay can be set either using potentiometers and DIP switches on the device or on the PC via the integrated RS485 interface.
- Realistic voltage transformation with tertiary winding — A set of voltage transformers with a tertiary winding extracts the displacement voltage, just as in a real installation.
- Analyzing neutral point displacement in real time — During a simulated ground fault, students record and display the voltage changes on the faulted and healthy phases.
- Ground-fault voltage relay (CO3301-4K) — This three-phase relay indicates operation and pick-up via LEDs and has a test button on the front and an RS485 interface.
- Voltage transformers, three-phase (CO3301-4V) — This class 1 transformer set is used to connect protective relays and has a tertiary winding in open-delta connection for measuring the displacement voltage.
- Line model 150 km / 300 km (CO3301-3A) — This three-phase model of a high-voltage overhead line allows the investigation of operating and fault conditions, especially asymmetrical ground faults.
- Circuit breaker module (CO3301-5P) — The module switches the line model manually or by remote control and applies specific ground faults.
- SCADA Viewer — The software controls and parameterizes the relay and records tripping behavior, displacement voltages and transients in real time.

From Knowledge Comes Capability.
You guide the learning
Where theory and practice go hand in hand.
RXLea brings a new way of learning: project-based, hands-on and clearly structured. Learners solve real-world tasks, while instructors save time on preparation. Interactive modules, smart analytics and real hardware create a modern, efficient learning world.
Hands-on and interactive
Animations, interactive tasks and realistic scenarios build a deep understanding. All content is organized into clear learning paths for focused, hands-on learning.
Digital support
3D assembly animations and digital instructions simplify complex procedures, reduce errors and help learners work more independently.
Visual support
Overview graphics, screenshots and sample animations make the learning world transparent. Photos from the learning packages are also available, including country-specific versions where needed.




Stay ahead in
technical training.
Get the latest training systems, product launches and educational insights, delivered directly to your inbox.