Investigations on Three Phase Cables
Investigations on Three Phase Cables
Expansion set for high-voltage underground cables: students measure charging power and the Ferranti effect, investigate load cases and determine the zero-sequence impedance during asymmetrical short circuits.
- Investigating the Ferranti effect and charging power
- Measuring load cases on cables
- Compensating reactive power
- Determining the zero-sequence impedance
- Realistic cable model
- Analyzing high capacitance per unit length
- Measuring the zero-sequence impedance
- Integrated transformer substation
In densely populated areas, high-voltage underground cables are increasingly replacing overhead lines. Cables behave quite differently: their high capacitance per unit length leads to charging power and a voltage rise at the open end. This expansion set replicates a three-phase cable with lengths of 12.5 km and 37.5 km at a scale of 1:1000 and feeds it via a 380 V/110 V transformer substation. Students measure the operating capacitance, investigate the Ferranti effect and load the cable with resistive, inductive and capacitive loads. They compensate reactive power, determine the zero-sequence impedance and analyze single-pole and two-pole short circuits with and without ground contact. The Power Quality Meters record all variables at the sending and receiving ends of the cable.
| Artikel-Nr. | Menge | Bezeichnung |
|---|---|---|
| Base Product | ||
| CO3301-3C | 1 | Kabelnachbildung 12,5 km / 37,5 km |
| CO3301-3M | 1 | Conversion station 380 V/110 V |
| CO3301-3F | 1 | Variable Ohmic load, three-phase, 1kW |
| CO3301-3E | 1 | Capacitive load, three-phase, 1kW |
| CO3301-3D | 1 | Inductive load, three-phase, 1kW |
| CO3301-5P | 1 | Power switch module |
| Software | ||
| SO4001-3H | 1 | Software SCADA Viewer |
| Course | ||
| SO2800-3L | 1 | Interactive Lab Assistant: High-voltage transmission lines |
| Measuring Instruments | ||
| CO5127-2S | 2 | Power Quality Meter mit Grafikdisplay und Langzeitspeicher |
| CO3301-3Z | 1 | Adjustable 3-phase power supply, 0-450V/2A |
| Accessories | ||
| LM9057 | 2 | Patch cable Cat5E 1x 1m yellow, 2x 2m yellow |
| LM8257 | 1 | USB 2.0 Ethernet adapter, 10/100 |
| LM9988 | 2 | 5-Port Ethernet Switch |
| ST8010-4J | 2 | Multiple socket outlet, 6 fold, with illuminated switch |
| Furniture | ||
| ST7200-7A | 1 | SybaPro experiment trolley, 3-level, 6 sockets, 1250x1970x800mm |
| ST8010-4T | 1 | Monitor holder for flat screen monitor of weight up to 15kg / 33lbs |
| ST7200-5L | 1 | Protection cover for three-level experiment trolleys |
| ST8010-4G | 1 | Keyboard adapter for flat screen monitor holders |
| Furniture Accessories | ||
| ST8000-4L | 1 | Display for Power Transmission equipment |
| Measurement Leads | ||
| SO5126-3R | 40 | Safety connecting plug 4mm with tap (2x), black, 1000V/32A CAT II |
| SO5126-3V | 2 | Safety connecting plug 4mm with tap (2x), blue, 1000V/32A CAT II |
| SO5126-3W | 7 | Safety connecting plug 4mm with tap (2x), green/yellow, 1000V/32A CAT II |
| SO5148-1L | 1 | Set of safety measurement cables, 4mm (31 leads) |
| SO5126-8B | 3 | Safety measurement cable 4mm, 25cm/10", black, 600V CAT III ~1000V CAT II / 32A |
| SO5126-8L | 6 | Safety measurement cable 4mm, 50cm/20", black, 600V CAT III ~1000V CAT II / 32A |
Learning Content in Detail
Investigating the Ferranti effect and charging power
Measuring load cases on cables
Compensating reactive power
Determining the zero-sequence impedance
Analyzing asymmetrical short circuits
Features & Applications
- Realistic cable model — This three-phase model replicates a high-voltage underground cable with lengths of 12.5 km and 37.5 km at a scale of 1:1000.
- Analyzing high capacitance per unit length — Students investigate the pronounced operating capacitance of cables and the resulting Ferranti effect and charging power.
- Measuring the zero-sequence impedance — The zero-sequence system can be determined by measurement under asymmetrical operating conditions and short circuits.
- Integrated transformer substation — A 380 V/110 V transformer substation adapts the voltage and current levels for the cable experiments true to scale.
- Cable model (CO3301-3C) — This three-phase underground cable model contains resistors, inductors and capacitors for lengths of 12.5 km and 37.5 km.
- Transformer substation 380 V/110 V (CO3301-3M) — The transformer feeds the cable model. It has a rated power of 400 VA and the vector group YNyn0.
- Power Quality Meter (CO5127-1S) — The digital power meter records all electrical variables and harmonics at the sending and receiving ends of the cable and outputs them via Ethernet.
- Load modules up to 1 kW — Three separate modules for resistive, inductive and capacitive loads allow wye, delta, series and parallel connections.
- SCADA for PowerLab — The software visualizes the grid parameters in the system diagram in real time and records the measurement series over time.

From Knowledge Comes Capability.
You guide the learning
Where theory and practice go hand in hand.
RXLea brings a new way of learning: project-based, hands-on and clearly structured. Learners solve real-world tasks, while instructors save time on preparation. Interactive modules, smart analytics and real hardware create a modern, efficient learning world.
Hands-on and interactive
Animations, interactive tasks and realistic scenarios build a deep understanding. All content is organized into clear learning paths for focused, hands-on learning.
Digital support
3D assembly animations and digital instructions simplify complex procedures, reduce errors and help learners work more independently.
Visual support
Overview graphics, screenshots and sample animations make the learning world transparent. Photos from the learning packages are also available, including country-specific versions where needed.




Stay ahead in
technical training.
Get the latest training systems, product launches and educational insights, delivered directly to your inbox.