Protection for Busbars Systems
Protection for Busbars Systems
Training system for busbar protection: participants compare the currents on a double busbar using summation current transformers, distinguish between faults inside and outside the protection zone and parameterize the time-overcurrent relay.
- Evaluating currents in normal operation
- Investigating short-circuit currents by measurement
- Assigning faults to the protection zone
- Parameterizing the time-overcurrent relay
- Carrying out switching operations in three ways
- Cascadable double busbar
- Hardware and software interlocking to prevent incorrect operation
- Busbar modules (CO3301-5R, CO3301-5S)
In large distribution substations, a fault in an outgoing feeder must not disconnect the entire busbar. Differential protection therefore distinguishes whether a fault lies inside or outside the protection zone. The system puts this principle into practice experimentally: using three summation current transformers, participants compare incoming and outgoing currents and apply Kirchhoff’s current law. They switch single-phase, two-phase and three-phase short circuits, parameterize the time-overcurrent relay and trip the circuit breaker in a targeted way. Switching operations can be carried out by hand, via control inputs or via SCADA. By the end, participants can detect internal faults even when current transformers saturate and assess the stabilization.
| Base Product | |
| CO3301-3A | Transmission line Model 150km/300km (93.2miles/186.4miles) |
| CO3301-5R | Double busbar unit, three-phase, incoming / outgoing feeder |
| CO3301-3F | Variable Ohmic load, three-phase, 1kW |
| CO3301-3H | Ohmic load 3x 560 Ohm |
| CO3301-4Y | Set of Balancing transformer |
| CO3301-4J | Überstromzeitrelais |
| CO3301-5P | Power switch module |
| SO2800-9M | Interactive Lab Assistant: Protection for bus bar systems |
| Software | |
| SO4001-3H | Software SCADA Viewer |
| Power Supply | |
| CO3301-3Z | Adjustable 3-phase power supply, 0-450V/2A |
| Measuring Instruments | |
| CO5127-1S | Three-phase power quality meter with display and long-term memory |
| Accessories | |
| LM9057 | Patch cable Cat5E 1x 1m yellow, 2x 2m yellow |
| LM8257 | USB 2.0 Ethernet adapter, 10/100 |
| LM9988 | 5-Port Ethernet Switch |
| ST8010-4J | Multiple socket outlet, 6 fold, with illuminated switch |
| LM9025 | Interface converter USB/RS485 |
| Furniture | |
| ST7200-7A | SybaPro experiment trolley, 3-level, 6 sockets, 1250x1970x800mm |
| ST8010-4T | Monitor holder for flat screen monitor of weight up to 15kg / 33lbs |
| ST7200-5L | Protection cover for three-level experiment trolleys |
| ST8010-4G | Keyboard adapter for flat screen monitor holders |
| Furniture Accessories | |
| ST8000-4N | Display for Energy Distribution equipment |
Learning Content in Detail
Evaluating currents in normal operation
Investigating short-circuit currents by measurement
Assigning faults to the protection zone
Parameterizing the time-overcurrent relay
Features & Applications
- Carrying out switching operations in three ways — Disconnect switches and circuit breakers can be switched by hand on the device, via 30 V control inputs or via Ethernet from the SCADA software.
- Cascadable double busbar — The modules can be combined to form any network topology. Participants use them to replicate real switchgear.
- Hardware and software interlocking to prevent incorrect operation — Impermissible switching operations are blocked and signaled both visually and audibly. This allows participants to try out switching sequences without risk.
- Busbar modules (CO3301-5R, CO3301-5S) — The modules bring data acquisition and monitoring functions directly into the feeder. Disconnect switches and circuit breakers operate autonomously via pushbuttons on the device or by remote control via the SCADA software.
- Protective relay (CO3301-4J) — The overload stage and short-circuit stage can be parameterized in an industry-oriented way using software or potentiometers.
- Summation current transformer set (CO3301-4Y) — The set has three three-phase current connections and determines the differential currents phase by phase.
- Lucas-Nülle SCADA Viewer — The software controls the system via Ethernet and displays its status. A data logger records measured values for analyzing transients, and a digital set square tool is used to measure graphs. A soft PLC to IEC 61131-3 allows users to create their own sequences.

From Knowledge Comes Capability.
You guide the learning
Where theory and practice go hand in hand.
RXLea brings a new way of learning: project-based, hands-on and clearly structured. Learners solve real-world tasks, while instructors save time on preparation. Interactive modules, smart analytics and real hardware create a modern, efficient learning world.
Hands-on and interactive
Animations, interactive tasks and realistic scenarios build a deep understanding. All content is organized into clear learning paths for focused, hands-on learning.
Digital support
3D assembly animations and digital instructions simplify complex procedures, reduce errors and help learners work more independently.
Visual support
Overview graphics, screenshots and sample animations make the learning world transparent. Photos from the learning packages are also available, including country-specific versions where needed.