Directional Power Protection
Directional Power Protection
Equipment set for the digital power and directional power relay: students set the tripping range, time stages and reset time and check when the relay disconnects the generator from the grid in the event of reverse power.
- Understanding the function and application of directional power protection
- Testing tripping thresholds with forward and reverse power
- Analyzing reset behavior
- Detecting forward and reverse power
- Parameterization via SCADA or directly on the device
- Precise delays for short-time and long-time stages
- Test and reset function
If the driving turbine fails during parallel operation, the generator continues to run as a synchronous motor and drives the turbine. The reverse power drawn in this situation can cause serious damage. The directional power relay detects the reversal of power flow in good time and selectively disconnects the generator from the grid. The equipment set replicates the measuring chain with a line model, variable load, circuit breaker and variable three-phase power supply. Students parameterize the tripping range, the short-time and long-time stages and the reset time using potentiometers and DIP switches or on the PC via RS485. They test the relay’s behavior with forward and reverse power and determine the reset ratio and reset time.
| Base Product | |
| CO3301-4G | Power and Reverse power relay |
| CO3301-3A | Transmission line Model 150km/300km (93.2miles/186.4miles) |
| CO3301-3F | Variable Ohmic load, three-phase, 1kW |
| CO3301-5P | Power switch module |
| SO2800-6L | Interactive Lab Assistant: Protective systems for high-voltage transmission line |
| Software | |
| SO4001-3H | Software SCADA Viewer |
| Power Supply | |
| CO3301-3Z | Adjustable 3-phase power supply, 0-450V/2A |
| Measuring Instruments | |
| CO5127-2S | Power Quality Meter mit Grafikdisplay und Langzeitspeicher |
| LM2330 | Multi13S digital multimeter |
| Accessories | |
| LM9057 | Patch cable Cat5E 1x 1m yellow, 2x 2m yellow |
| LM8257 | USB 2.0 Ethernet adapter, 10/100 |
| LM9988 | 5-Port Ethernet Switch |
| ST8010-4J | Multiple socket outlet, 6 fold, with illuminated switch |
| LM9025 | Interface converter USB/RS485 |
| Furniture | |
| ST7200-7A | SybaPro experiment trolley, 3-level, 6 sockets, 1250x1970x800mm |
| ST8010-4T | Monitor holder for flat screen monitor of weight up to 15kg / 33lbs |
| ST7200-5L | Protection cover for three-level experiment trolleys |
| ST8010-4G | Keyboard adapter for flat screen monitor holders |
| Furniture Accessories | |
| ST8000-4L | Display for Power Transmission equipment |
| Measurement Leads | |
| SO5126-3R | Safety connecting plug 4mm with tap (2x), black, 1000V/32A CAT II |
| SO5126-3V | Safety connecting plug 4mm with tap (2x), blue, 1000V/32A CAT II |
| SO5126-3W | Safety connecting plug 4mm with tap (2x), green/yellow, 1000V/32A CAT II |
| SO5148-1L | Set of safety measurement cables, 4mm (31 leads) |
Learning Content in Detail
Understanding the function and application of directional power protection
Testing tripping thresholds with forward and reverse power
Analyzing reset behavior
Features & Applications
- Detecting forward and reverse power — The relay monitors the real power output of generators and reliably detects reverse power such as occurs when the turbine fails.
- Parameterization via SCADA or directly on the device — The relay can be set either using potentiometers and DIP switches on the device or on the PC via the RS485 interface.
- Precise delays for short-time and long-time stages — A short-time tripping stage can be set for steam turbines and a long-time stage for general power fluctuations.
- Test and reset function — Self-test software and a configurable reset time ensure that even short power peaks are reliably detected and totaled.
- Power and directional power relay (CO3301-4G) — This single-phase directional relay in accordance with ANSI 32 and 37 has a configurable tripping range, an adjustable disconnection time and an RS485 interface.
- Line model 150 km / 300 km (CO3301-3A) — This three-phase model of a high-voltage overhead line at a scale of 1:1000 allows measurements in various operating states.
- Circuit breaker module (CO3301-5P) — The module switches manually or by remote control during load or direction changes and indicates its status via indicator lamps.
- Variable resistive load (CO3301-3F) — Three synchronously adjustable toroidal rheostats provide infinitely variable simulation of load changes and reverse power.
- Variable three-phase power supply 0–450 V / 2 A (CO3301-3Z) — This infinitely variable power supply with variable transformer and motor protection circuit breaker supplies the system safely.
- SCADA Viewer — The software controls and parameterizes the relay and records power curves, direction detection and tripping times in real time.

From Knowledge Comes Capability.
You guide the learning
Where theory and practice go hand in hand.
RXLea brings a new way of learning: project-based, hands-on and clearly structured. Learners solve real-world tasks, while instructors save time on preparation. Interactive modules, smart analytics and real hardware create a modern, efficient learning world.
Hands-on and interactive
Animations, interactive tasks and realistic scenarios build a deep understanding. All content is organized into clear learning paths for focused, hands-on learning.
Digital support
3D assembly animations and digital instructions simplify complex procedures, reduce errors and help learners work more independently.
Visual support
Overview graphics, screenshots and sample animations make the learning world transparent. Photos from the learning packages are also available, including country-specific versions where needed.




Stay ahead in
technical training.
Get the latest training systems, product launches and educational insights, delivered directly to your inbox.