Skip to content

Closed-Loop Control of an Air-Temperature Control Loop

RXLea
Digital projects for hands-on learningInteractive learning content, directly connected to the training system.

Closed-Loop Control of an Air-Temperature Control Loop

IAC31PT

Training system for identifying and optimizing temperature control. A low-mass heating element, three platinum sensors and a speed-controlled fan deliver fast, reproducible experiment results.

Learning Content
  • Carrying out system identification
  • Analyzing step responses
  • Analyzing the Bode diagram
  • Parameterizing controllers
KEY FEATURES
  • Fast temperature system
  • Reproducible results thanks to a controlled fan
  • Integrated measuring and control instruments
  • Three temperature sensors at different positions
Speak with a Product Specialist +1 (757) 808-5696 · sales@lucas-nuelle.com

Temperature control is a critical process step in hardening furnaces, process plants and air-conditioning systems. The training system reproduces this kind of controlled system without the long waiting times of thermal plants: a low-mass heating element heats an air stream, and three fast platinum temperature sensors at different distances provide different system parameters. A speed-controlled fan keeps the air flow constant, making experiments repeatable. Learners record step responses, evaluate the frequency response in the Bode diagram and design two-position, three-position and PID controllers. The hardware continuously monitors the temperature and switches off automatically in the event of overheating.

CO3620-2CAir-temperature controlled system
SO2802-3CInteractive Lab Assistant: Closed-loop control of an air-temperature control loop
CO3620-2AUniversal digital controller (DSP)
ST7200-7ASybaPro experiment trolley, 3-level, 6 sockets, 1250x1970x800mm
ST8010-4TMonitor holder for flat screen monitor of weight up to 15kg / 33lbs
ST7200-5LProtection cover for three-level experiment trolleys
ST8010-4GKeyboard adapter for flat screen monitor holders
ST8008-8NProtected power distribution for working stations
ST8010-4JMultiple socket outlet, 6 fold, with illuminated switch
ST8000-6ADisplay for the Control Technology equipment
SO5148-1VSet of safety measurement cables, 4mm (20 leads)
SO5126-3RSafety connecting plug 4mm with tap (2x), black, 1000V/32A CAT II
SO5126-3VSafety connecting plug 4mm with tap (2x), blue, 1000V/32A CAT II

Learning Content in Detail

Learners identify the thermal system in the time and frequency domains, design switching and continuous controllers and evaluate their behavior under load.

Carrying out system identification

Learners determine the control parameters in the time and frequency domains.

Analyzing step responses

Learners evaluate the inflection tangent and the time percentage characteristics.

Analyzing the Bode diagram

Learners evaluate the frequency response of the open-loop temperature system.

Parameterizing controllers

Learners design two-position, three-position and PID controllers.

Investigating load steps

Learners evaluate the disturbance and reference response of the temperature control system.

Features & Applications

The experiments are taken from heating and air-conditioning technology, process automation and process engineering, and range from system analysis to disturbance feedforward.
  • Fast temperature system — The low-mass heating element responds quickly, giving learners short experiment times instead of long heating-up phases.
  • Reproducible results thanks to a controlled fan — A speed-controlled fan regulates the air flow, allowing learners to create exact and repeatable test conditions.
  • Integrated measuring and control instruments — Recording step responses, analyzing dynamic behavior and tuning the PID controller: everything takes place directly on the system.
  • Three temperature sensors at different positions — The three fast platinum temperature sensors are located at different distances from the heating element and therefore produce different system parameters.
  • Intrinsically safe design — The hardware continuously monitors the temperature and switches off automatically in the event of overheating.
  • Air temperature control system (CO3620-2C) — The controlled system comprises the low-mass heating element and three fast platinum temperature sensors at different distances.
  • Integrated power amplifier — The amplifier drives the heating element directly. Learners vary the manipulated variable continuously without adding external components.
  • Speed-controlled fan — The air flow, controlled by the speed-controlled fan, ensures reproducible results.
  • Digital universal controller (CO3620-2A) — The universal control unit comes with numerous interfaces for typical controlled systems. Its software functions handle real-time analysis and control.
  • Step response plotter — Learners record the system’s response to an input step in real time and use it to determine the static and dynamic parameters of the controlled system.
  • PID controller — Learners parameterize all controller components interactively and specifically optimize the disturbance and reference response of the connected controlled system.
  • Bode plotter — Amplitude and phase response are displayed. Learners use them to carry out frequency response analysis for systematic controller optimization.
  • Cascaded PID controller — The instrument is used to set up and optimize cascade control made up of temperature and speed control.
  • System analyzer — The tool compares measured data with models in both the time and the frequency domain, so theory can be applied immediately.
Learners working with RXLea on a tablet at a Lucas-Nuelle training system
RXLea

From Knowledge Comes Capability.

You guide the learning

Where theory and practice go hand in hand.

RXLea brings a new way of learning: project-based, hands-on and clearly structured. Learners solve real-world tasks, while instructors save time on preparation. Interactive modules, smart analytics and real hardware create a modern, efficient learning world.

Hands-on and interactive

Animations, interactive tasks and realistic scenarios build a deep understanding. All content is organized into clear learning paths for focused, hands-on learning.

Digital support

3D assembly animations and digital instructions simplify complex procedures, reduce errors and help learners work more independently.

Visual support

Overview graphics, screenshots and sample animations make the learning world transparent. Photos from the learning packages are also available, including country-specific versions where needed.

Learners using a tablet at an energy training system
RXLea on desktop, laptop and tablet
RXLea Path Creator for building learning journeys
RXLea Navigator showing the learning world
Learn more about RXLea
Newsletter

Stay ahead in
technical training.

Get the latest training systems, product launches and educational insights, delivered directly to your inbox.

Your email address

By subscribing, you agree to our Privacy Policy. You can unsubscribe at any time.

 Please select at least one category before subscribing.
I'm interested in - select all that apply