Protection of Parallel-Connected Lines
Protection of Parallel-Connected Lines
Equipment set for protecting parallel lines: students combine time-overcurrent and directional relays, create a time coordination plan and check selectivity in the event of a short circuit.
- Understanding the protection requirements of parallel lines
- Defining protection direction and pick-up values
- Creating a time coordination plan
- Checking the selectivity of the protection system
- Selectivity through combined protection concepts
- Investigating the (n-1) criterion in practice
- Parameterization via SCADA or by hand
- Tuning time coordination in the grid
In meshed networks and with parallel lines, simple time-overcurrent protection is not sufficient to locate the fault. Only the additional evaluation of the power flow direction keeps the healthy line in operation and satisfies the (n-1) criterion. For this purpose, the equipment set combines time-overcurrent relays at the sending end of the line with directional relays at the receiving end. Students set up the parallel transmission line from two line models, define the protection direction and pick-up values and coordinate the tripping delays into a time coordination plan. They then apply short circuits at various points and check whether only the affected section is disconnected.
| Artikel-Nr. | Menge | Bezeichnung |
|---|---|---|
| Base Product | ||
| CO3301-4J | 2 | Überstromzeitrelais |
| CO3301-4D | 2 | Time Overcurrent Relay with directional feature |
| CO3301-3A | 2 | Transmission line Model 150km/300km (93.2miles/186.4miles) |
| CO3301-5P | 5 | Power switch module |
| CO3301-3F | 1 | Variable Ohmic load, three-phase, 1kW |
| SO2800-6L | 1 | Interactive Lab Assistant: Protective systems for high-voltage transmission line |
| Software | ||
| SO4001-3H | 1 | Software SCADA Viewer |
| Power Supply | ||
| CO3301-3Z | 1 | Adjustable 3-phase power supply, 0-450V/2A |
| Measuring Instruments | ||
| CO5127-2S | 1 | Power Quality Meter mit Grafikdisplay und Langzeitspeicher |
| LM2330 | 1 | Multi13S digital multimeter |
| Accessories | ||
| LM9057 | 1 | Patch cable Cat5E 1x 1m yellow, 2x 2m yellow |
| LM8257 | 1 | USB 2.0 Ethernet adapter, 10/100 |
| LM9988 | 1 | 5-Port Ethernet Switch |
| ST8010-4J | 2 | Multiple socket outlet, 6 fold, with illuminated switch |
| LM9025 | 1 | Interface converter USB/RS485 |
| Furniture | ||
| ST7200-7A | 1 | SybaPro experiment trolley, 3-level, 6 sockets, 1250x1970x800mm |
| ST8010-4T | 1 | Monitor holder for flat screen monitor of weight up to 15kg / 33lbs |
| ST7200-5L | 1 | Protection cover for three-level experiment trolleys |
| ST8010-4G | 1 | Keyboard adapter for flat screen monitor holders |
| Furniture Accessories | ||
| ST8000-4L | 1 | Display for Power Transmission equipment |
| Measurement Leads | ||
| SO5126-3R | 40 | Safety connecting plug 4mm with tap (2x), black, 1000V/32A CAT II |
| SO5126-3V | 10 | Safety connecting plug 4mm with tap (2x), blue, 1000V/32A CAT II |
| SO5126-3W | 10 | Safety connecting plug 4mm with tap (2x), green/yellow, 1000V/32A CAT II |
| SO5148-1L | 1 | Set of safety measurement cables, 4mm (31 leads) |
Learning Content in Detail
Understanding the protection requirements of parallel lines
Defining protection direction and pick-up values
Creating a time coordination plan
Checking the selectivity of the protection system
Features & Applications
- Selectivity through combined protection concepts — Non-directional and directional time-overcurrent relays work together. This allows faults in the ring network to be located and selectively disconnected.
- Investigating the (n-1) criterion in practice — Students check whether the failure of one line interrupts normal operation and use this to assess security of supply.
- Parameterization via SCADA or by hand — The relays can be set using the front panel controls or on the PC via the integrated RS485 interface.
- Tuning time coordination in the grid — Tripping delays and tripping directions are set individually and combined into a consistent time coordination plan.
- Time-overcurrent relay (CO3301-4J) — This three-phase relay detects overloads and short circuits at the sending end of the line.
- Directional time-overcurrent relay (CO3301-4D) — This digital relay detects the power flow direction and selectively protects the receiving end of the line.
- Line models 150 km / 300 km (CO3301-3A) — Two three-phase models of high-voltage overhead lines form the parallel transmission lines.
- Circuit breaker module (CO3301-5P) — The module applies and removes faults manually or by remote control. Indicator lamps show the operating status.
- Variable three-phase power supply 0–450 V / 2 A (CO3301-3Z) — This infinitely variable power supply with variable transformer feeds the line network.
- SCADA Viewer — The software controls and parameterizes the networked protective relays and monitors the line states in real time.

From Knowledge Comes Capability.
You guide the learning
Where theory and practice go hand in hand.
RXLea brings a new way of learning: project-based, hands-on and clearly structured. Learners solve real-world tasks, while instructors save time on preparation. Interactive modules, smart analytics and real hardware create a modern, efficient learning world.
Hands-on and interactive
Animations, interactive tasks and realistic scenarios build a deep understanding. All content is organized into clear learning paths for focused, hands-on learning.
Digital support
3D assembly animations and digital instructions simplify complex procedures, reduce errors and help learners work more independently.
Visual support
Overview graphics, screenshots and sample animations make the learning world transparent. Photos from the learning packages are also available, including country-specific versions where needed.




Stay ahead in
technical training.
Get the latest training systems, product launches and educational insights, delivered directly to your inbox.