Skip to content

Testing directional time-overcurrent protection in ring networks

RXLea
Digital projects for hands-on learningInteractive learning content, directly connected to the training system.

Testing directional time-overcurrent protection in ring networks

ELP21PT

Equipment set for directional time-overcurrent protection: students set pick-up values, tripping times and the characteristic angle and check selectivity with power flowing in both directions.

Learning Content
  • Explaining function and areas of application
  • Parameterizing the protective relay
  • Determining the inherent system operating time
  • Checking the selectivity of direction detection
KEY FEATURES
  • Detecting power flow direction
  • Parameterization via SCADA or directly on the device
  • Creating short circuits safely
  • Flexible tripping characteristics
Speak with a Product Specialist +1 (757) 808-5696 · sales@lucas-nuelle.com

In meshed networks and loop circuits, simple time-overcurrent protection is not sufficient for selective disconnection. Directional protection also detects the direction of power flow: the relay uses current, voltage and phase angle to determine whether the fault lies upstream or downstream of the measuring point. The equipment set replicates a line section with a line model, circuit breaker, variable load and variable three-phase power supply. Students set pick-up values, tripping times and the characteristic angle, either via the front panel buttons or on the PC via RS485. They create specific short circuits, record the inverse-time tripping characteristic and determine the inherent operating time of the protection system for different fault types.

CO3301-4DTime Overcurrent Relay with directional feature
CO3301-5NRelay Test Unit
CO3301-3ATransmission line Model 150km/300km (93.2miles/186.4miles)
CO3301-3FVariable Ohmic load, three-phase, 1kW
CO3301-5PPower switch module
SO2800-6LInteractive Lab Assistant: Protective systems for high-voltage transmission line
SO4001-3HSoftware SCADA Viewer
CO3301-3ZAdjustable 3-phase power supply, 0-450V/2A
CO5127-2SPower Quality Meter mit Grafikdisplay und Langzeitspeicher
LM2330Multi13S digital multimeter
LM9057Patch cable Cat5E 1x 1m yellow, 2x 2m yellow
LM8257USB 2.0 Ethernet adapter, 10/100
LM99885-Port Ethernet Switch
ST8010-4JMultiple socket outlet, 6 fold, with illuminated switch
LM9025Interface converter USB/RS485
ST7200-7ASybaPro experiment trolley, 3-level, 6 sockets, 1250x1970x800mm
ST8010-4TMonitor holder for flat screen monitor of weight up to 15kg / 33lbs
ST7200-5LProtection cover for three-level experiment trolleys
ST8010-4GKeyboard adapter for flat screen monitor holders
ST8000-4LDisplay for Power Transmission equipment
SO5126-3RSafety connecting plug 4mm with tap (2x), black, 1000V/32A CAT II
SO5126-3VSafety connecting plug 4mm with tap (2x), blue, 1000V/32A CAT II
SO5126-3WSafety connecting plug 4mm with tap (2x), green/yellow, 1000V/32A CAT II
SO5148-1LSet of safety measurement cables, 4mm (31 leads)

Learning Content in Detail

Students explore the function and parameterization of directional protection and verify selectivity and timing behavior in experiments.

Explaining function and areas of application

Students find out where directional time-overcurrent protection is used and how it works.

Parameterizing the protective relay

Students set the pick-up values, tripping times and the relay characteristic angle (RCA).

Determining the inherent system operating time

Students measure the inherent operating time of the protection system for different fault types.

Checking the selectivity of direction detection

Students test the relay with power flowing in the forward and reverse directions.

Recording the tripping characteristic

Students record the relay’s inverse-time (IDMT) tripping characteristic in practice.

Features & Applications

The experiments address the protection of meshed networks and ring networks fed from both ends, as well as selective overload and short-circuit protection with detection of the power flow direction.
  • Detecting power flow direction — The relay distinguishes between faults in the forward and reverse directions. This allows it to be used selectively in loop circuits.
  • Parameterization via SCADA or directly on the device — The relay can be set either by hand using the front panel buttons or on the PC via the RS485 interface.
  • Creating short circuits safely — Students deliberately trigger short circuits and use them to test the tripping stages of the relay. Users and equipment remain protected.
  • Flexible tripping characteristics — The relay operates as definite-time (DMT) or inverse-time (IDMT) overcurrent protection with normal inverse, very inverse or extremely inverse characteristics.
  • Directional time-overcurrent relay (CO3301-4D) — This digital relay has an adjustable relay characteristic angle (RCA) and an RS485 interface.
  • Line model 150 km / 300 km (CO3301-3A) — This three-phase model of an overhead line at a scale of 1:1000 allows realistic analyses of operation and faults.
  • Circuit breaker module (CO3301-5P) — The module switches the voltage on and off by remote control during simulated short circuits and indicates its status.
  • Variable resistive load (CO3301-3F) — Synchronously adjustable toroidal rheostats simulate loads in wye or delta connection.
  • Variable three-phase power supply 0–450 V / 2 A (CO3301-3Z) — This infinitely variable power supply with variable transformer and motor protection circuit breaker supplies the system safely.
  • SCADA Viewer — The software controls and parameterizes the relay and records the tripping behavior and inherent system operating time in real time.
Learners working with RXLea on a tablet at a Lucas-Nuelle training system
RXLea

From Knowledge Comes Capability.

You guide the learning

Where theory and practice go hand in hand.

RXLea brings a new way of learning: project-based, hands-on and clearly structured. Learners solve real-world tasks, while instructors save time on preparation. Interactive modules, smart analytics and real hardware create a modern, efficient learning world.

Hands-on and interactive

Animations, interactive tasks and realistic scenarios build a deep understanding. All content is organized into clear learning paths for focused, hands-on learning.

Digital support

3D assembly animations and digital instructions simplify complex procedures, reduce errors and help learners work more independently.

Visual support

Overview graphics, screenshots and sample animations make the learning world transparent. Photos from the learning packages are also available, including country-specific versions where needed.

Learners using a tablet at an energy training system
RXLea on desktop, laptop and tablet
RXLea Path Creator for building learning journeys
RXLea Navigator showing the learning world
Learn more about RXLea
Newsletter

Stay ahead in
technical training.

Get the latest training systems, product launches and educational insights, delivered directly to your inbox.

Your email address

By subscribing, you agree to our Privacy Policy. You can unsubscribe at any time.

 Please select at least one category before subscribing.
I'm interested in - select all that apply