Power Grid Synchronization 300W
Power Grid Synchronization 300W
Teach secure grid synchronization and how to control active and reactive power. This complete training system perfectly prepares your students for power plant operations.
- Checking the synchronization conditions
- Connecting the generator using lamp circuits
- Working with a synchroscope and double instruments
- Setting real and reactive power
- Lamp circuits and synchroscope compared
- Complete sequence through to grid operation
- Generator unit made up of three coordinated components
- Synchronizing unit with all measuring instruments
A generator may only be connected to the grid when its voltage, frequency and phase angle match those of the grid. If any of these quantities deviates, there is a risk of serious damage to the machine and disturbances in the grid. The training system makes this process easy to follow in the laboratory: the servo machine test system drives the three-phase synchronous machine like a turbine, and the synchronizing unit provides the control station with a lamp circuit, double voltmeter, double frequency meter and synchroscope. Learners match the conditions step by step, determine the switching instant and connect the generator manually. They then vary the drive torque and excitation and observe how the real and reactive power change.
| Base Product | |
| CO3212-6V6 | Synchronization Unit |
| CO3212-1J7 | Motor protection switch, 0.7 - 1A |
| SE2682-3Q7 | Three-phase synchronous machine, 0,3 kW |
| CO3301-5G | Exciter voltage controller with de-excitation |
| SO2805-1G7 | Interactive Lab Assistant: Sync. machines, synchronization 0.3 kW |
| Power Supply | |
| CO3212-5V7 | Three-phase power supply with motor protection switch |
| Measuring Instruments | |
| CO5127-2A | Power-Multimeter |
| Accessories | |
| CO3636-6X7 | Dynamic servo machine test stand for 300W machines incl. control software ActiveServo 2.0 |
| SE2662-2A | Rubber coupling sleeve, 0.3kW |
| SE2662-7C | Coupling guard with LED lighting for 300W machines |
| Furniture | |
| ST8010-4G | Keyboard adapter for flat screen monitor holders |
| ST8008-8N7 | Protected power distribution for workstations |
| ST8010-4J8 | Multiple power outlet strip, 6 outlets, US-standard |
| Furniture Accessories | |
| ST8000-5A | Display for Electrical Machines equipment |
| Measurement Leads | |
| SO5148-1L | Set of safety measurement cables, 4mm (31 leads) |
| SO5126-3R | Safety connecting plug 4mm with tap (2x), black, 1000V/32A CAT II |
| SO5126-3V | Safety connecting plug 4mm with tap (2x), blue, 1000V/32A CAT II |
| SO5126-3W | Safety connecting plug 4mm with tap (2x), green/yellow, 1000V/32A CAT II |
Learning Content in Detail
Checking the synchronization conditions
Connecting the generator using lamp circuits
Working with a synchroscope and double instruments
Setting real and reactive power
Features & Applications
- Lamp circuits and synchroscope compared — Learners try out the dark-lamp, bright-lamp and rotating-lamp methods and compare them with the instrument-assisted method using the synchroscope. They see how accurate each method is and where its limits lie.
- Complete sequence through to grid operation — After connection, the generator remains on the grid. Learners set the real power via the prime mover and the reactive power via the excitation controller. This shows how drive power and excitation interact.
- Generator unit made up of three coordinated components — The prime mover, synchronous generator and control station together form a laboratory-scale power plant unit. Learners adjust the speed of the prime mover while keeping an eye on the synchronizing instruments.
- Synchronizing unit with all measuring instruments — The 3-lamp circuit, double voltmeter, double frequency meter, synchroscope and synchronizing switch are clearly arranged on one panel. Learners work through the synchronization conditions step by step and connect the generator.
- Synchronous generator with accessible excitation winding — The three-phase synchronous machine has a cylindrical rotor and converts the mechanical energy of the prime mover into electrical energy. The stator and excitation winding are brought out to touch-proof 4 mm sockets.
- Servo machine test system in the role of the turbine — The test system drives the generator. Learners fine-tune the speed to reduce the beat frequency and, after synchronization, vary the torque to control the real power.

From Knowledge Comes Capability.
You guide the learning
Where theory and practice go hand in hand.
RXLea brings a new way of learning: project-based, hands-on and clearly structured. Learners solve real-world tasks, while instructors save time on preparation. Interactive modules, smart analytics and real hardware create a modern, efficient learning world.
Hands-on and interactive
Animations, interactive tasks and realistic scenarios build a deep understanding. All content is organized into clear learning paths for focused, hands-on learning.
Digital support
3D assembly animations and digital instructions simplify complex procedures, reduce errors and help learners work more independently.
Visual support
Overview graphics, screenshots and sample animations make the learning world transparent. Photos from the learning packages are also available, including country-specific versions where needed.




Stay ahead in
technical training.
Get the latest training systems, product launches and educational insights, delivered directly to your inbox.