Micro Grid – Stand-Alone Operation (Synchronization unit)
Micro Grid – Stand-Alone Operation (Synchronization unit)
Master autonomous microgrids for independent energy supply. Our training system teaches complex island grid control, enabling you to manage load changes, match generation to demand, and ensure stable voltage/frequency.
- Building self-sufficient island grids
- Analysis of load changes
- Control of real and reactive power
- Using SCADA systems
- Emulation of harsh island grid conditions
- Interactive smart metering
- PC and SCADA control
- Servo machine test stand
Due to the energy transition, standalone micro grids are becoming increasingly important. With this system by Lucas-Nuelle, learners train the complex control mechanisms of an island grid operating independently from the main grid. Your students learn how a local generator must stabilize voltage and frequency entirely on its own. They acquire the crucial skills to safely manage active and reactive load changes. They align power generation precisely with local demand, ideal for critical infrastructure or remote areas. Utilize cutting-edge smart metering technologies and prepare professionals for the challenges of decentralized power supply.
| Base Product | |
| CO3212-6V2 | Synchronization Unit |
| CO3301-5P | Power switch module |
| SO2800-3X7 | Interactive Lab Assistant: Control of stand-alone networks with Micro Grid |
| SE2682-5Q7 | Three-phase synchronous machine with smooth core rotor, 1kW |
| CO3301-5G8 | Exciter voltage controller with de-excitation |
| CO3212-1P7 | Motor protection switch, 3 pole, 2,8-4A; US Version |
| CO3301-5L | HMI (Human Machine Interface) for generators |
| CO3301-3F | Variable Ohmic load, three-phase, 1kW |
| CO3301-3E | Capacitive load, three-phase, 1kW |
| CO3301-3D | Inductive load, three-phase, 1kW |
| CO3301-5P | Power switch module |
| Software | |
| SO4001-3F | Software SCADA for Power Engineering, designer software |
| Power Supply | |
| CO3212-5V7 | Three-phase power supply with motor protection switch |
| Measuring Instruments | |
| CO5127-2S | Power Quality Meter mit Grafikdisplay und Langzeitspeicher |
| Accessories | |
| LM9057 | Patch cable Cat5E 1x 1m yellow, 2x 2m yellow |
| LM8257 | USB 2.0 Ethernet adapter, 10/100 |
| LM9988-8 | 5-Port Ethernet Switch (International) |
| ST8010-4J8 | Multiple power outlet strip, 6 outlets, US-standard |
| CO3636-6Y7 | Servo machine test stand for 1kW machines incl. software ActiveServo (D,GB,F,E) |
| SE2662-7D | Coupling guard with LED lighting for 1kW machines |
| SE2662-6A | Rubber coupling sleeve, 1kW |
| Furniture | |
| ST8010-4G | Keyboard adapter for flat screen monitor holders |
| ST8008-8N7 | Protected power distribution for workstations |
| ST8010-4J8 | Multiple power outlet strip, 6 outlets, US-standard |
| Furniture Accessories | |
| ST8000-4B | Display for Microgrid equipment |
| Measurement Leads | |
| SO5126-3R | Safety connecting plug 4mm with tap (2x), black, 1000V/32A CAT II |
| SO5126-3V | Safety connecting plug 4mm with tap (2x), blue, 1000V/32A CAT II |
| SO5126-3W | Safety connecting plug 4mm with tap (2x), green/yellow, 1000V/32A CAT II |
| SO5148-1L | Set of safety measurement cables, 4mm (31 leads) |
| SO5126-8A | Safety measurement cable 4mm, 25cm/10", red, 600V CAT III ~1000V CAT II / 32A |
| SO5126-8B | Safety measurement cable 4mm, 25cm/10", black, 600V CAT III ~1000V CAT II / 32A |
| SO5126-8E | Safety measurement cable 4mm, 25cm/10", blue, 600V CAT III ~1000V CAT II / 32A |
| SO5126-9A | Safety measurement cable 4mm, 100cm/40", blue, 600V CAT III ~1000V CAT II / 32A |
| SO5126-9C | Safety measurement cable 4mm, 100cm/40", gr/ye, 600V CAT III ~1000V CAT II / 32A |
| SO5126-9P | Safety measurement cable 4mm, 150cm/60", green, 600V CAT III ~1000V CAT II / 32A |
Learning Content in Detail
Building self-sufficient island grids
Analysis of load changes
Control of real and reactive power
Using SCADA systems
Features & Applications
- Emulation of harsh island grid conditions — Learners train in a self-sufficient subgrid without any buffering effect. They experience directly how complex loads influence frequency and voltage.
- Interactive smart metering — Use the generator HMI to evaluate real, reactive and apparent power in detail. This allows you to monitor the balancing node precisely.
- PC and SCADA control — Operate the system manually or via SCADA. This bridges the gap between physical control and modern control technology.
- Servo machine test stand — The test stand emulates the drive turbine dynamically. Learners understand how the machine has to readjust during load changes.
- Three-phase complex loads — Replicate extreme load scenarios. Understand how reactive power influences the terminal voltage in an isolated grid.
- SCADA for PowerLab — Use real-time data logging and a virtual control room. Operate switches directly from the digital interface.

From Knowledge Comes Capability.
You guide the learning
Where theory and practice go hand in hand.
RXLea brings a new way of learning: project-based, hands-on and clearly structured. Learners solve real-world tasks, while instructors save time on preparation. Interactive modules, smart analytics and real hardware create a modern, efficient learning world.
Hands-on and interactive
Animations, interactive tasks and realistic scenarios build a deep understanding. All content is organized into clear learning paths for focused, hands-on learning.
Digital support
3D assembly animations and digital instructions simplify complex procedures, reduce errors and help learners work more independently.
Visual support
Overview graphics, screenshots and sample animations make the learning world transparent. Photos from the learning packages are also available, including country-specific versions where needed.




Stay ahead in
technical training.
Get the latest training systems, product launches and educational insights, delivered directly to your inbox.