Skip to content

Complex Loads, Power Consumption Measurement and Peak Load Monitoring

RXLea
Digital projects for hands-on learningInteractive learning content, directly connected to the training system.

Complex Loads, Power Consumption Measurement and Peak Load Monitoring

ESG12PT-7

Students analyze static and dynamic three-phase consumers, measure energy consumption, and perform manual and automatic reactive power compensation. This system provides learners with complete practical training equipment.

Learning Content
  • Analyzing complex loads
  • Carrying out and evaluating reactive power compensation
  • Measuring and evaluating energy
  • Commissioning dynamic loads
KEY FEATURES
  • Modular emulation of complex three-phase loads
  • Compensating reactive power manually and automatically
  • Energy monitoring and connection to the smart grid
  • Intelligent power factor controller with connection detection
Speak with a Product Specialist +1 (757) 808-5696 · sales@lucas-nuelle.com

The efficient use of electrical energy and maintaining grid quality are central challenges for modern power grids. Reactive power caused by inductive consumers puts additional strain on these grids and must be compensated. This training system provides practical methods for analyzing complex consumers. You will learn to measure energy consumption and perform manual and automatic reactive power compensation. The system perfectly prepares you for the challenges of intelligent power grids.

CO3208-4L7Lamp board 230V
CO3301-5C7Reactive power controller
CO3301-5J7Switchable Capacitor Battery
SE2683-1R7Three-phase asynchronous motor, squirrel-cage, 1 kW, 360/208 V
CO3212-2DStar-Delta switch
CO3212-1P7Motor protection switch, 3 pole, 2,8-4A; US Version
CO3301-5PPower switch module
SO2800-3Y7Interactive Lab Assistant: Energy management
CO3301-3FVariable Ohmic load, three-phase, 1kW
CO3301-3ECapacitive load, three-phase, 1kW
CO3301-3DInductive load, three-phase, 1kW
CO3301-5PPower switch module
CO3212-5V7Three-phase power supply with motor protection switch
CO5127-2SPower Quality Meter mit Grafikdisplay und Langzeitspeicher
CO5127-2APower-Multimeter
LM9057Patch cable Cat5E 1x 1m yellow, 2x 2m yellow
LM8257USB 2.0 Ethernet adapter, 10/100
LM9988-85-Port Ethernet Switch (International)
ST8010-4J8Multiple power outlet strip, 6 outlets, US-standard
CO3636-6Y7Servo machine test stand for 1kW machines incl. software ActiveServo (D,GB,F,E)
SE2662-7DCoupling guard with LED lighting for 1kW machines
SE2662-6ARubber coupling sleeve, 1kW
ST8010-4GKeyboard adapter for flat screen monitor holders
ST8008-8N7Protected power distribution for workstations
ST8010-4J8Multiple power outlet strip, 6 outlets, US-standard
ST8000-4CDisplay for Energy Management equipment
SO5126-3RSafety connecting plug 4mm with tap (2x), black, 1000V/32A CAT II
SO5126-3VSafety connecting plug 4mm with tap (2x), blue, 1000V/32A CAT II
SO5126-3WSafety connecting plug 4mm with tap (2x), green/yellow, 1000V/32A CAT II
SO5148-1LSet of safety measurement cables, 4mm (31 leads)
SO5148-1ZSet of safety measurement cables, 4mm, 10m, 5 pcs, incl. fastening

Learning Content in Detail

Students work their way from analyzing individual loads to automatic compensation and evaluating energy consumption in the three-phase grid.

Analyzing complex loads

Students use measurements to investigate resistive, inductive and capacitive loads and their combinations in wye and delta connection.

Carrying out and evaluating reactive power compensation

Students determine the reactive power demand of an induction motor, calculate the capacitance and compensate both manually and automatically.

Measuring and evaluating energy

Students measure P, Q, S and cos φ with the power quality meter and record load profiles to determine peak loads.

Commissioning dynamic loads

Students commission an induction motor as a dynamic load and analyze its influence on the power factor.

Features & Applications

The experiments address tasks from industrial energy management, power quality analysis with reactive power compensation and peak load management in smart grids.
  • Modular emulation of complex three-phase loads — Resistive, inductive and capacitive components form R, L, C, RL, RC and RLC loads in wye or delta connection. Students use them to investigate balanced and unbalanced industrial and household loads and their effects on the grid.
  • Compensating reactive power manually and automatically — Students analyze the reactive power demand of an induction motor, calculate the compensation capacitance and first switch the capacitor steps manually. The industrial reactive power controller then takes over load-dependent control.
  • Energy monitoring and connection to the smart grid — The power quality meter records real, reactive and apparent power, power factor and harmonics and delivers the data via Ethernet to the SCADA software, where load profiles are generated as the basis for peak load management.
  • Intelligent power factor controller with connection detection — The controller automatically detects the wiring and step ratings. Students use it to practice wizard-assisted commissioning and analyze the control behavior in four-quadrant operation.
  • SCADA for PowerLab — The software replicates an industrial control room: monitoring the power quality meter’s measured values in real time, recording load profiles and switching states, and comparing grid and motor parameters during compensation.
Learners working with RXLea on a tablet at a Lucas-Nuelle training system
RXLea

From Knowledge Comes Capability.

You guide the learning

Where theory and practice go hand in hand.

RXLea brings a new way of learning: project-based, hands-on and clearly structured. Learners solve real-world tasks, while instructors save time on preparation. Interactive modules, smart analytics and real hardware create a modern, efficient learning world.

Hands-on and interactive

Animations, interactive tasks and realistic scenarios build a deep understanding. All content is organized into clear learning paths for focused, hands-on learning.

Digital support

3D assembly animations and digital instructions simplify complex procedures, reduce errors and help learners work more independently.

Visual support

Overview graphics, screenshots and sample animations make the learning world transparent. Photos from the learning packages are also available, including country-specific versions where needed.

Learners using a tablet at an energy training system
RXLea on desktop, laptop and tablet
RXLea Path Creator for building learning journeys
RXLea Navigator showing the learning world
Learn more about RXLea
Newsletter

Stay ahead in
technical training.

Get the latest training systems, product launches and educational insights, delivered directly to your inbox.

Your email address

By subscribing, you agree to our Privacy Policy. You can unsubscribe at any time.

 Please select at least one category before subscribing.
I'm interested in - select all that apply