Micro Grid – Isolated Parallel Operation (Multifunction relay)
Micro Grid – Isolated Parallel Operation (Multifunction relay)
Extension to the EMG12PT for parallel island operation: students synchronize a second generator to a weak grid and share real and reactive power via droop control or SCADA.
- Synchronizing a second generator to a weak grid
- Applying P and Q droop control
- Parameterizing load sharing via SCADA
- Correcting reactive power oscillations
- Interaction of several generators
- Communication versus autonomy
- Analyzing circulating currents in practice
- Servo machine test bench (CO3636-6Y)
If one generator is not sufficient for an island grid or redundancy is required, several machines have to work together. Frequency and voltage are then not rigidly specified but are supported jointly by all generators. This extension adds a second machine set to the EMG12PT, consisting of a synchronous machine, servo machine test bench, excitation voltage controller, generator HMI and multifunction relay. Students synchronize the second machine to the weak grid and then share the load: once purely physically via P and Q droop characteristics without a communication line, and once network-based via SCADA. They provoke instabilities, observe equalizing currents and correct reactive power oscillations via the excitation currents.
| Base Product | |
| CO3301-5W | Multifunktionsrelais, Leistungsregler, cos-phi Regler, Synchronisiergerät |
| CO3301-5P | Power switch module |
| SO2800-3X | Interactive Lab Assistant: Control of stand-alone networks with Micro Grid |
| CO3212-1P | Motor protection switch, 3 pole, 1.8-2.5A |
| CO3301-5L | HMI (Human Machine Interface) for generators |
| Accessories | |
| ST8010-4J | Multiple socket outlet, 6 fold, with illuminated switch |
| CO3636-6Y | Servo machine test stand for 1kW machines incl. software ActiveServo (D,GB,F,E) |
| SE2662-7D | Coupling guard with LED lighting for 1kW machines |
| SE2662-6A | Rubber coupling sleeve, 1kW |
| Furniture | |
| ST7200-7A | SybaPro experiment trolley, 3-level, 6 sockets, 1250x1970x800mm |
| ST8010-4T | Monitor holder for flat screen monitor of weight up to 15kg / 33lbs |
| ST7200-5L | Protection cover for three-level experiment trolleys |
| ST8010-4G | Keyboard adapter for flat screen monitor holders |
| ST8008-8N | Protected power distribution for working stations |
| ST8010-4J | Multiple socket outlet, 6 fold, with illuminated switch |
| Furniture Accessories | |
| ST8000-4B | Display for Microgrid equipment |
| Measurement Leads | |
| SO5126-3R | Safety connecting plug 4mm with tap (2x), black, 1000V/32A CAT II |
| SO5126-3V | Safety connecting plug 4mm with tap (2x), blue, 1000V/32A CAT II |
| SO5126-3W | Safety connecting plug 4mm with tap (2x), green/yellow, 1000V/32A CAT II |
| SO5148-1L | Set of safety measurement cables, 4mm (31 leads) |
| SO5148-1Z | Set of safety measurement cables, 4mm, 10m, 5 pcs, incl. fastening |
Learning Content in Detail
Synchronizing a second generator to a weak grid
Applying P and Q droop control
Parameterizing load sharing via SCADA
Correcting reactive power oscillations
Features & Applications
- Interaction of several generators — In a pure island grid, all active generators jointly support frequency and voltage. Students experience how every intervention on machine A has an immediate effect on machine B.
- Communication versus autonomy — Control is either network-based via SCADA as load sharing or purely physical via droop characteristics without a communication line. Students compare the two strategies in terms of reliability.
- Analyzing circulating currents in practice — Students provoke instabilities in the safe lab environment and learn how controllers must intervene to suppress equalizing currents and reactive power oscillations.
- Servo machine test bench (CO3636-6Y) — The test bench emulates the drive turbine and responds dynamically to load changes. Students see how the prime mover has to readjust its torque to maintain the grid frequency.
- Three-phase complex loads (CO3301-3F, -3D, -3E) — With the adjustable resistive, inductive and capacitive elements, students replicate extreme load scenarios and observe how reactive power affects the terminal voltage.
- Digital multifunction relay (CO3301-5W) — The industrial device combines frequency and phase matching, power distribution and alarm acknowledgment in one physical interface. Students practice the complete automation process there.
- SCADA for PowerLab — For load sharing, the software links the control PCs via TCP/IP as client and server. It records the frequency and voltage of both generators synchronously, thus showing the P/f and Q/V droop characteristics.

From Knowledge Comes Capability.
You guide the learning
Where theory and practice go hand in hand.
RXLea brings a new way of learning: project-based, hands-on and clearly structured. Learners solve real-world tasks, while instructors save time on preparation. Interactive modules, smart analytics and real hardware create a modern, efficient learning world.
Hands-on and interactive
Animations, interactive tasks and realistic scenarios build a deep understanding. All content is organized into clear learning paths for focused, hands-on learning.
Digital support
3D assembly animations and digital instructions simplify complex procedures, reduce errors and help learners work more independently.
Visual support
Overview graphics, screenshots and sample animations make the learning world transparent. Photos from the learning packages are also available, including country-specific versions where needed.




Stay ahead in
technical training.
Get the latest training systems, product launches and educational insights, delivered directly to your inbox.