Skip to content

Micro Grid – Isolated Parallel Operation (Multifunction relay)

RXLea
Digital projects for hands-on learningInteractive learning content, directly connected to the training system.

Micro Grid – Isolated Parallel Operation (Multifunction relay)

EMG12PT

Training system for self-sufficient island grids: students automatically control the voltage and frequency of a master generator and handle sharp load changes without the support of an interconnected grid.

Learning Content
  • Setting up the island grid and parameterizing the generator
  • Analyzing the effects of load changes
  • Controlling real and reactive power in the island grid
  • Monitoring energy flows via SCADA
KEY FEATURES
  • Real conditions of an island grid
  • Smart metering at the balancing node
  • Operation on the hardware and via SCADA
  • Servo machine test bench (CO3636-6Y)
Speak with a Product Specialist +1 (757) 808-5696 · sales@lucas-nuelle.com

In an island grid, there is no interconnected grid to support frequency and voltage. A local generator must maintain both on its own, even when loads are suddenly switched on and off. This training system replicates such a grid with real industrial components: a 1 kW synchronous machine, a servo machine test bench as the drive turbine, an excitation voltage controller, a generator HMI, a multifunction relay and adjustable RLC loads. Students set up the island grid, parameterize the generator as master and connect complex loads. They measure voltage and frequency dips, return the system to rated operation via the excitation current and drive torque and evaluate the energy flows at the balance node with SCADA.

CO3301-5WMultifunktionsrelais, Leistungsregler, cos-phi Regler, Synchronisiergerät
CO3301-5PPower switch module
SO2800-3XInteractive Lab Assistant: Control of stand-alone networks with Micro Grid
SE2682-5QThree-phase synchronous machine with smooth core rotor, 1kW
CO3301-5GExciter voltage controller with de-excitation
CO3212-1PMotor protection switch, 3 pole, 1.8-2.5A
CO3301-5LHMI (Human Machine Interface) for generators
CO3301-3FVariable Ohmic load, three-phase, 1kW
CO3301-3ECapacitive load, three-phase, 1kW
CO3301-3DInductive load, three-phase, 1kW
CO3301-5PPower switch module
SO4001-3FSoftware SCADA for Power Engineering, designer software
CO3212-5VThree-phase power supply with motor protection switch
CO5127-1SThree-phase power quality meter with display and long-term memory
LM9057Patch cable Cat5E 1x 1m yellow, 2x 2m yellow
LM8257USB 2.0 Ethernet adapter, 10/100
LM99885-Port Ethernet Switch
ST8010-4JMultiple socket outlet, 6 fold, with illuminated switch
CO3636-6YServo machine test stand for 1kW machines incl. software ActiveServo (D,GB,F,E)
SE2662-7DCoupling guard with LED lighting for 1kW machines
SE2662-6ARubber coupling sleeve, 1kW
ST7200-7ASybaPro experiment trolley, 3-level, 6 sockets, 1250x1970x800mm
ST8010-4TMonitor holder for flat screen monitor of weight up to 15kg / 33lbs
ST7200-5LProtection cover for three-level experiment trolleys
ST8010-4GKeyboard adapter for flat screen monitor holders
ST8008-8NProtected power distribution for working stations
ST8010-4JMultiple socket outlet, 6 fold, with illuminated switch
ST8000-4BDisplay for Microgrid equipment
SO5126-3RSafety connecting plug 4mm with tap (2x), black, 1000V/32A CAT II
SO5126-3VSafety connecting plug 4mm with tap (2x), blue, 1000V/32A CAT II
SO5126-3WSafety connecting plug 4mm with tap (2x), green/yellow, 1000V/32A CAT II
SO5148-1LSet of safety measurement cables, 4mm (31 leads)
SO5126-8ASafety measurement cable 4mm, 25cm/10", red, 600V CAT III ~1000V CAT II / 32A
SO5126-8BSafety measurement cable 4mm, 25cm/10", black, 600V CAT III ~1000V CAT II / 32A
SO5126-8ESafety measurement cable 4mm, 25cm/10", blue, 600V CAT III ~1000V CAT II / 32A
SO5126-9ASafety measurement cable 4mm, 100cm/40", blue, 600V CAT III ~1000V CAT II / 32A
SO5126-9CSafety measurement cable 4mm, 100cm/40", gr/ye, 600V CAT III ~1000V CAT II / 32A
SO5126-9PSafety measurement cable 4mm, 150cm/60", green, 600V CAT III ~1000V CAT II / 32A

Learning Content in Detail

Students work through the island grid from setup and analysis of load changes to control and remote monitoring of ongoing operation.

Setting up the island grid and parameterizing the generator

Students set up a self-sufficient microgrid and configure the generator as master with stable voltage and frequency.

Analyzing the effects of load changes

Students measure the consequences of abrupt resistive, inductive and capacitive load changes and explain the causes.

Controlling real and reactive power in the island grid

Students return the system to rated operation after disturbances via the excitation current and drive torque.

Monitoring energy flows via SCADA

Students use SCADA and smart metering, evaluate series of measurements and control the island grid remotely.

Features & Applications

The experiments reflect the tasks of decentralized supply: setting up self-sufficient grids for remote areas and critical infrastructure, taking over supply with local generators in the event of grid failure and balancing autonomous subgrids via smart metering.
  • Real conditions of an island grid — In a self-sufficient subgrid, the supporting effect of a large interconnected grid is absent. Students experience directly how connecting complex loads affects frequency and voltage.
  • Smart metering at the balancing node — Using the generator HMI, students evaluate real, reactive and apparent power in the system in detail.
  • Operation on the hardware and via SCADA — The system can be operated manually on the hardware and entirely via the SCADA environment. Students thus combine machine control via speed and excitation with modern telecontrol and control system technology.
  • Servo machine test bench (CO3636-6Y) — The test bench emulates the drive turbine and responds dynamically to load changes. Students see how the prime mover has to readjust its torque to keep the grid frequency stable.
  • Three-phase complex loads (CO3301-3F, -3D, -3E) — With the adjustable resistive, inductive and capacitive elements, students replicate extreme load scenarios and observe how reactive power affects the terminal voltage.
  • Digital multifunction relay (CO3301-5W) — The industrial device combines frequency and phase matching, power distribution and alarm acknowledgment in one physical interface. Students practice the complete automation process there.
  • SCADA for PowerLab — The software serves as the control system of the microgrid. It records frequency and voltage curves during abrupt load connections, and students switch circuit breakers, generators and loads directly from the user interface.
Learners working with RXLea on a tablet at a Lucas-Nuelle training system
RXLea

From Knowledge Comes Capability.

You guide the learning

Where theory and practice go hand in hand.

RXLea brings a new way of learning: project-based, hands-on and clearly structured. Learners solve real-world tasks, while instructors save time on preparation. Interactive modules, smart analytics and real hardware create a modern, efficient learning world.

Hands-on and interactive

Animations, interactive tasks and realistic scenarios build a deep understanding. All content is organized into clear learning paths for focused, hands-on learning.

Digital support

3D assembly animations and digital instructions simplify complex procedures, reduce errors and help learners work more independently.

Visual support

Overview graphics, screenshots and sample animations make the learning world transparent. Photos from the learning packages are also available, including country-specific versions where needed.

Learners using a tablet at an energy training system
RXLea on desktop, laptop and tablet
RXLea Path Creator for building learning journeys
RXLea Navigator showing the learning world
Learn more about RXLea
Newsletter

Stay ahead in
technical training.

Get the latest training systems, product launches and educational insights, delivered directly to your inbox.

Your email address

By subscribing, you agree to our Privacy Policy. You can unsubscribe at any time.

 Please select at least one category before subscribing.
I'm interested in - select all that apply