Smart grid: the energy chain from generator to load management
Smart grid: the energy chain from generator to load management
Modular training system in panel format: students analyze power transmission, protection technology and demand side management on real hardware and control the grid via a SCADA environment.
- Analyzing physical effects on transmission lines
- Performing switching operations in a double busbar system
- Parameterizing and testing digital power system protection devices
- Developing demand side management strategies
- Physically replicating the energy chain through to the consumer
- Investigating critical grid states safely
- Implementing demand side management interactively
- Double busbar with industrial switching logic
The energy transition requires flexible, intelligently controlled grids instead of rigid structures. The training system physically replicates the energy chain right through to the consumer: double busbar, overhead line model for 150 and 300 km, time-overcurrent relay, Power Quality Meter and a variable three-phase supply. Students perform switching operations on the double busbar, parameterize the digital protective relay and investigate critical states such as short circuits or the Ferranti effect within a safe voltage range. Via the SCADA environment, they couple load switches with control logic and trigger automated load shedding at peak load. In this way, they combine the physical fundamentals of power transmission with the digital control of modern load management scenarios.
| Base Product | |
| CO3301-5R | Double busbar unit, three-phase, incoming / outgoing feeder |
| CO3301-3A | Transmission line Model 150km/300km (93.2miles/186.4miles) |
| CO3301-4J | Überstromzeitrelais |
| CO3301-3F | Variable Ohmic load, three-phase, 1kW |
| CO3301-5P | Power switch module |
| CO3208-4L | Lamp board 230V |
| SO2800-9R | Interactive Lab Assistant: Introduction to Smart Grid Technology |
| Software | |
| SO4001-3H | Software SCADA Viewer |
| Power Supply | |
| CO3301-3Z | Adjustable 3-phase power supply, 0-450V/2A |
| Measuring Instruments | |
| CO5127-1S | Three-phase power quality meter with display and long-term memory |
| Accessories | |
| LM9057 | Patch cable Cat5E 1x 1m yellow, 2x 2m yellow |
| LM8257 | USB 2.0 Ethernet adapter, 10/100 |
| LM9988 | 5-Port Ethernet Switch |
| LM9025 | Interface converter USB/RS485 |
| Furniture | |
| ST7200-7A | SybaPro experiment trolley, 3-level, 6 sockets, 1250x1970x800mm |
| ST8010-4T | Monitor holder for flat screen monitor of weight up to 15kg / 33lbs |
| ST7200-5L | Protection cover for three-level experiment trolleys |
| ST8010-4G | Keyboard adapter for flat screen monitor holders |
| Furniture Accessories | |
| ST8000-4A | Display for Smart Grid equipment |
| Measurement Leads | |
| SO5126-3R | Safety connecting plug 4mm with tap (2x), black, 1000V/32A CAT II |
| SO5126-3V | Safety connecting plug 4mm with tap (2x), blue, 1000V/32A CAT II |
| SO5126-3W | Safety connecting plug 4mm with tap (2x), green/yellow, 1000V/32A CAT II |
| SO5148-1L | Set of safety measurement cables, 4mm (31 leads) |
Learning Content in Detail
Analyzing physical effects on transmission lines
Performing switching operations in a double busbar system
Parameterizing and testing digital power system protection devices
Developing demand side management strategies
Features & Applications
- Physically replicating the energy chain through to the consumer — All stages of the power supply are present as hardware. Students use them to explore system-wide interdependencies and feedback effects in the power grid.
- Investigating critical grid states safely — The system uses industrial protection and measurement technology while remaining within the safe voltage range. Short circuits and the Ferranti effect can be reproduced experimentally without endangering students.
- Implementing demand side management interactively — Load switches and SCADA logic are coupled, enabling automated load shedding at peak load. Students thus acquire directly applicable skills for the stability of modern power grids.
- Double busbar with industrial switching logic — The CO3301-5R unit allows complex switching operations, up to and including an uninterrupted busbar changeover. Students use it to practice the correct switching sequence that prevents operating errors in grid operation.
- Time-overcurrent relay CO3301-4J — The digital protective relay offers normal, severely and extremely inverse tripping characteristics. Students learn how selectivity in power system protection is achieved through parameterization.
- SCADA Designer & Viewer for PowerLab — Central tool for monitoring and control: visualize power flows and switching states in real time, analyze transient events such as short circuits with the data logger, program soft PLC logic for energy management and parameterize devices via RS485 or Ethernet.

From Knowledge Comes Capability.
You guide the learning
Where theory and practice go hand in hand.
RXLea brings a new way of learning: project-based, hands-on and clearly structured. Learners solve real-world tasks, while instructors save time on preparation. Interactive modules, smart analytics and real hardware create a modern, efficient learning world.
Hands-on and interactive
Animations, interactive tasks and realistic scenarios build a deep understanding. All content is organized into clear learning paths for focused, hands-on learning.
Digital support
3D assembly animations and digital instructions simplify complex procedures, reduce errors and help learners work more independently.
Visual support
Overview graphics, screenshots and sample animations make the learning world transparent. Photos from the learning packages are also available, including country-specific versions where needed.




Stay ahead in
technical training.
Get the latest training systems, product launches and educational insights, delivered directly to your inbox.