Fault Ride Through
Fault Ride Through
This specialized training system lets students investigate the grid fault behavior (FRT) of modern wind turbines. They emulate reactions to symmetrical and asymmetrical voltage sags using real hardware.
- Analysis of grid faults
- Optimization of reactive power support
- Application of transformation methods
- Development of protection strategies
- Hardware emulation of grid faults
- DFIG control system in the 1 kW class
- Symmetrical components method
- Adjustable grid fault simulator
Integrating large amounts of wind power requires turbines to remain stable during brief grid faults. This system enables you to investigate complex fault ride-through scenarios (LVRT/HVRT) in a practical setting using a dynamic grid fault simulator and a 1 kW DFIG generator. By analyzing positive, negative and zero sequence systems as well as d/q control structures, you develop the competence to master modern grid connection requirements. Give learners the best possible preparation for the demands of the energy industry.
| Base Product | |
| CO3208-3C2 | Dynamic grid fault simulator |
| SO2800-3S7 | Interactive Lab Assistant: Fault Ride-Through of wind power plants |
| CO3208-3A7 | Control unit for wind turbine, double-fed asynchronous generator |
| SE2682-6W7 | Three-phase multi-function machine, 1.0kW |
| CO3208-3B7 | 3-phase isolation transformer, 1kW for wind power plants |
| SE2682-5T | Incremental position encoder 1024 pulses |
| SE2662-6A | Rubber coupling sleeve, 1kW |
| SE2662-7D | Coupling guard with LED lighting for 1kW machines |
| SO2800-3R7 | Interactive Lab Assistant: Windkraftanlagen mit DFIG |
| Add-on | |
| CO5127-2S | Power Quality Meter mit Grafikdisplay und Langzeitspeicher |
| CO3301-5R | Double busbar unit, three-phase, incoming / outgoing feeder |
| LM9057 | Patch cable Cat5E 1x 1m yellow, 2x 2m yellow |
| LM8257 | USB 2.0 Ethernet adapter, 10/100 |
| LM9988-8 | 5-Port Ethernet Switch (International) |
| SO5148-1Z | Set of safety measurement cables, 4mm, 10m, 5 pcs, incl. fastening |
| CO3301-3Z | Adjustable 3-phase power supply, 0-450V/2A |
| CO3212-5V | Three-phase power supply with motor protection switch |
| Power Supply | |
| CO3212-5V7 | Three-phase power supply with motor protection switch |
| Measuring Instruments | |
| CO5127-2A | Power-Multimeter |
| Accessories | |
| CO3636-6Y7 | Servo machine test stand for 1kW machines incl. software ActiveServo (D,GB,F,E) |
| SE2662-7D | Coupling guard with LED lighting for 1kW machines |
| SE2662-6A | Rubber coupling sleeve, 1kW |
| Furniture | |
| ST8010-4G | Keyboard adapter for flat screen monitor holders |
| ST8008-8N7 | Protected power distribution for workstations |
| ST8010-4J8 | Multiple power outlet strip, 6 outlets, US-standard |
| Furniture Accessories | |
| ST8000-4D | Display for Wind Power Plants equipment |
| Measurement Leads | |
| SO5126-3R | Safety connecting plug 4mm with tap (2x), black, 1000V/32A CAT II |
| SO5126-3W | Safety connecting plug 4mm with tap (2x), green/yellow, 1000V/32A CAT II |
| SO5126-3V | Safety connecting plug 4mm with tap (2x), blue, 1000V/32A CAT II |
| SO5148-1L | Set of safety measurement cables, 4mm (31 leads) |
Learning Content in Detail
Analysis of grid faults
Optimization of reactive power support
Application of transformation methods
Development of protection strategies
Features & Applications
- Hardware emulation of grid faults — Generate real single-, two- and three-phase voltage dips. Learners validate theoretical models directly in a safe laboratory environment.
- DFIG control system in the 1 kW class — Use controllers with machine-side and grid-side converters.
- Symmetrical components method — Break down currents and voltages into positive, negative and zero sequence systems. Complex analysis methods for unbalanced faults become practically applicable.
- Adjustable grid fault simulator — Precisely adjust the fault duration and dip depth. Test the stability of the turbine in a targeted way and compare different controller settings.
- Brake chopper & crowbar logic — Real protective circuits limit the DC link voltage. Measurements make the operating principle of hardware protection in the event of a fault tangible.
- FRT Monitor & Control Center — Central software for real-time analysis and control. Configure real and reactive power support and record data automatically.

From Knowledge Comes Capability.
You guide the learning
Where theory and practice go hand in hand.
RXLea brings a new way of learning: project-based, hands-on and clearly structured. Learners solve real-world tasks, while instructors save time on preparation. Interactive modules, smart analytics and real hardware create a modern, efficient learning world.
Hands-on and interactive
Animations, interactive tasks and realistic scenarios build a deep understanding. All content is organized into clear learning paths for focused, hands-on learning.
Digital support
3D assembly animations and digital instructions simplify complex procedures, reduce errors and help learners work more independently.
Visual support
Overview graphics, screenshots and sample animations make the learning world transparent. Photos from the learning packages are also available, including country-specific versions where needed.




Stay ahead in
technical training.
Get the latest training systems, product launches and educational insights, delivered directly to your inbox.