Voltage Control in a Local Power Grid
Voltage Control in a Local Power Grid
This system provides learners with practical techniques for grid stabilization in modern local grids with high photovoltaic integration. They use controllable distribution transformers and inverter derating to regulate voltage.
- Assessing the influence on the voltage band
- Configuring automated control loops
- Applying real power limitation on the inverter
- Analyzing energy flows in the smart grid
- Investigating a smart grid in a closed experimental setup
- Replicating automated tap changer logic
- Controlling the inverter’s real and reactive power
- Motorized variable transformer CO3301-3P
With every additional distributed photovoltaic system, it becomes more difficult to keep the grid voltage within the permissible band despite fluctuating feed-in. The training system replicates this task in the laboratory: PV feed-in, variable loads and grid control components form a closed experimental setup. A motor-driven variable transformer takes on the role of the voltage-regulated distribution transformer, and a power quality meter supplies the measured variables for the control system. From these, students build automatic control loops, limit the inverter’s real power and provide reactive power for voltage support. They follow the energy flows in the SCADA software. In this way, they learn how grid stability is ensured in smart grid scenarios.
| Base Product | |
| CO3301-3N | Isolating transformer, Three-phase, 1kW |
| CO3301-3P7 | Three-phase variable transformer with motor drive |
| CO3208-4P7 | Solar panel emulator, 1.5 kW, 500 V |
| CO3208-1Q7 | 3-phase industrial photovoltaic inverter |
| CO3301-3F | Variable Ohmic load, three-phase, 1kW |
| SO2800-6V7 | Interactive Lab Assistant: Photovoltaikanlagen - Professional |
| Software | |
| SO4001-3H | Software SCADA Viewer |
| Power Supply | |
| CO3212-5V7 | Three-phase power supply with motor protection switch |
| Measuring Instruments | |
| CO5127-2S | Power Quality Meter mit Grafikdisplay und Langzeitspeicher |
| Accessories | |
| LM9057 | Patch cable Cat5E 1x 1m yellow, 2x 2m yellow |
| LM8257 | USB 2.0 Ethernet adapter, 10/100 |
| LM9988-8 | 5-Port Ethernet Switch (International) |
| ST8010-4J8 | Multiple power outlet strip, 6 outlets, US-standard |
| Furniture | |
| ST7200-7A7 | Mobile workstation, 3 level frame, 6 sockets, 1250x1970x800 mm, 49"x77.5"x31.5" |
| ST8010-4T | Monitor holder for flat screen monitor of weight up to 15kg / 33lbs |
| ST7200-5L | Protection cover for three-level experiment trolleys |
| ST8010-4G | Keyboard adapter for flat screen monitor holders |
| Furniture Accessories | |
| ST8000-4G | Display for Photovoltaic Professional equipment |
| Measurement Leads | |
| SO5126-3R | Safety connecting plug 4mm with tap (2x), black, 1000V/32A CAT II |
| SO5126-3W | Safety connecting plug 4mm with tap (2x), green/yellow, 1000V/32A CAT II |
| SO5126-3V | Safety connecting plug 4mm with tap (2x), blue, 1000V/32A CAT II |
| SO5148-1L | Set of safety measurement cables, 4mm (31 leads) |
Learning Content in Detail
Assessing the influence on the voltage band
Configuring automated control loops
Applying real power limitation on the inverter
Analyzing energy flows in the smart grid
Features & Applications
- Investigating a smart grid in a closed experimental setup — PV feed-in, variable loads and grid control components are combined in a single setup. Students investigate the relationship between feed-in power and grid voltage without putting a supply grid at risk.
- Replicating automated tap changer logic — The power quality meter and the motor-driven transformer together replicate the control system of a voltage-regulated distribution transformer (VRDT). Students translate theory into a working hardware control loop and observe the readjustment under load.
- Controlling the inverter’s real and reactive power — The derating and reactive power provision of the PV inverter can be investigated in a targeted way. Students recognize how distributed generators support the voltage instead of simply disconnecting in the event of overload.
- Motorized variable transformer CO3301-3P — The component replicates the voltage-regulated distribution transformer. By changing the transformation ratio under load, voltage fluctuations are compensated in a visible and measurable way.
- SCADA for PowerLab — The control room software visualizes and controls the system. Students monitor DC and AC power, voltages, currents, frequency and power factor in real time, specify setpoints for derating and reactive power and use the logger to record long-term measurements such as the weekly yield.

From Knowledge Comes Capability.
You guide the learning
Where theory and practice go hand in hand.
RXLea brings a new way of learning: project-based, hands-on and clearly structured. Learners solve real-world tasks, while instructors save time on preparation. Interactive modules, smart analytics and real hardware create a modern, efficient learning world.
Hands-on and interactive
Animations, interactive tasks and realistic scenarios build a deep understanding. All content is organized into clear learning paths for focused, hands-on learning.
Digital support
3D assembly animations and digital instructions simplify complex procedures, reduce errors and help learners work more independently.
Visual support
Overview graphics, screenshots and sample animations make the learning world transparent. Photos from the learning packages are also available, including country-specific versions where needed.




Stay ahead in
technical training.
Get the latest training systems, product launches and educational insights, delivered directly to your inbox.