Contactor Circuits on Three-Phase Motors with 24 V Control Voltage
Contactor Circuits on Three-Phase Motors with 24 V Control Voltage
Practical training equipment in the box system for industrial installation and control technology: learners wire contactor circuits for three-phase motors, with the control circuit operating at 24 V throughout.
- Creating and analyzing circuit diagrams
- Setting motor protection relays properly
- Building a self-holding circuit
- Implementing reversing controls
- Installing industrial components, creating circuit diagrams
- Control circuit at 24 V throughout
- Building all standard industrial circuits
- Setting motor protection and wiring fault signals
Installation technology does not stop at residential and functional spaces; it is just as important in the commercial and industrial sector. This box system introduces learners to installing industrial components in plants. The training focuses on the logic of control technology, the standards-compliant installation of cables and the parameterization of devices. The SybaTrain boxes, the 0.3 kW three-phase induction motor, main and auxiliary contactors, timing relays and motor protection relays are used to build the standard industrial circuits, from self-holding to the automatic wye-delta reversing circuit. The control circuit carries 24 V throughout. By the end, learners draw circuit diagrams, set motor protection according to the nameplate and evaluate fault signals.
| Measuring Instruments | |
| SE2501-2G | Mains connection box, 230V |
| Accessories | |
| LM8554 | Voltage, phase + continuity tester with field direction indicator, max. 400V |
| LM2323 | TRMS digital multimeter MetraHit 2+, CAT III |
| SE2501-2E | Mains connection box, 230V |
| SE2501-3H | Junction box, 5x 4 sockets |
| SO5148-1M | Set of safety measurement cables, 4mm (23 leads), for Instrain |
| ST8003-5Q | Punched hole panel, interchangeable, for 1200 mm panel mounting frames |
| SE2501-1D | Spannungsversorgung 230V einphasig, Kaltgerätestecker |
| Furniture | |
| ST7200-7A | SybaPro experiment trolley, 3-level, 6 sockets, 1250x1970x800mm |
| ST8010-4T | Monitor holder for flat screen monitor of weight up to 15kg / 33lbs |
| ST7200-5L | Protection cover for three-level experiment trolleys |
| Measurement Leads | |
| SO5148-1D | Set of safety measurement cables, 4mm (53 leads) |
Learning Content in Detail
Creating and analyzing circuit diagrams
Setting motor protection relays properly
Building a self-holding circuit
Implementing reversing controls
Wiring wye-delta starting
Evaluating fault signals
Features & Applications
- Installing industrial components, creating circuit diagrams — Learners install industrial components and create the associated circuit diagrams directly at the setup. This keeps planning and wiring directly linked.
- Control circuit at 24 V throughout — The control circuit is operated entirely at 24 V. During the experiments, learners work on a circuit that does not carry line voltage.
- Building all standard industrial circuits — From the self-holding circuit to the automatic wye-delta reversing circuit, all common industrial circuits can be built. The scope thus ranges from the very first basic circuit to starting control.
- Setting motor protection and wiring fault signals — Learners set the motor protection relay and build contactor circuits that output a fault signal in the event of an overload. This makes the overload case easy to follow in the experiment.
- Three-phase induction motor, 0.3 kW — The industrial motor has a pronounced breakdown torque and an electronic nameplate (EDD) that provides the motor data.
- On-delay and off-delay timing relays — The timing relays are used to create time-dependent controls, as required by the automatic wye-delta circuit.
- SybaTrain experiment boxes with a view inside — The compact, robust modules are built into transparent housings, so the installed components and circuits remain fully visible at all times. Equipped with 4 mm safety jacks, they combine maximum transparency with fast, clearly laid-out and safe experiment setups.
- Interactive Lab Assistant (ILA) — The SO2801-4F multimedia course guides learners through all the contactor circuit experiments with interactive circuit diagrams and animations.

From Knowledge Comes Capability.
You guide the learning
Where theory and practice go hand in hand.
RXLea brings a new way of learning: project-based, hands-on and clearly structured. Learners solve real-world tasks, while instructors save time on preparation. Interactive modules, smart analytics and real hardware create a modern, efficient learning world.
Hands-on and interactive
Animations, interactive tasks and realistic scenarios build a deep understanding. All content is organized into clear learning paths for focused, hands-on learning.
Digital support
3D assembly animations and digital instructions simplify complex procedures, reduce errors and help learners work more independently.
Visual support
Overview graphics, screenshots and sample animations make the learning world transparent. Photos from the learning packages are also available, including country-specific versions where needed.




Stay ahead in
technical training.
Get the latest training systems, product launches and educational insights, delivered directly to your inbox.