Micro Grid (Multifunction Relay) with Extensions: Renewables, Loads
Micro Grid (Multifunction Relay) with Extensions: Renewables, Loads
Complete training equipment for island grid control, automatic synchronization and active/reactive power control in microgrids, with connection of renewable generators, power plant emulation and complex loads.
- Analyzing microgrid operating modes
- Configuring automatic synchronization
- Controlling voltage and reactive power
- Controlling active power and frequency
- Automatic synchronization and grid control
- Switching operating modes during the experiment
- Integrating renewable generators from PV and wind
- Integrating power plants and pumped storage
With every kilowatt-hour of distributed generation fed in, the distribution grid changes: rigid feeders are becoming microgrids that balance generation and consumption themselves. Reliably mastering island operation, grid-parallel operation and automatic synchronization requires an understanding of the system that can only be built up on a live grid. This training system provides a complete microgrid in the laboratory: a generator module with the CO3301-5W multifunction relay, photovoltaic infeed, a wind turbine with DFIG, power plant and pumped-storage emulation, and three-phase R/L/C loads. Students control active and reactive power, investigate the dynamics during grid disturbances and operate the system via the SCADA software as if from a control room.
| Base Product | |
| CO3301-5W | Multifunktionsrelais, Leistungsregler, cos-phi Regler, Synchronisiergerät |
| CO3301-5P | Power switch module |
| SO2800-3X | Interactive Lab Assistant: Control of stand-alone networks with Micro Grid |
| SE2682-5Q | Three-phase synchronous machine with smooth core rotor, 1kW |
| CO3301-5G | Exciter voltage controller with de-excitation |
| CO3212-1P | Motor protection switch, 3 pole, 1.8-2.5A |
| CO3301-5L | HMI (Human Machine Interface) for generators |
| CO3301-3F | Variable Ohmic load, three-phase, 1kW |
| CO3301-3E | Capacitive load, three-phase, 1kW |
| CO3301-3D | Inductive load, three-phase, 1kW |
| CO3301-5P | Power switch module |
| CO5127-1S | Three-phase power quality meter with display and long-term memory |
| CO3212-5V | Three-phase power supply with motor protection switch |
| LM9057 | Patch cable Cat5E 1x 1m yellow, 2x 2m yellow |
| LM8257 | USB 2.0 Ethernet adapter, 10/100 |
| LM9988 | 5-Port Ethernet Switch |
| ST8010-4J | Multiple socket outlet, 6 fold, with illuminated switch |
| CO3636-6Y | Servo machine test stand for 1kW machines incl. software ActiveServo (D,GB,F,E) |
| SE2662-7D | Coupling guard with LED lighting for 1kW machines |
| SE2662-6A | Rubber coupling sleeve, 1kW |
| SO4001-3F | Software SCADA for Power Engineering, designer software |
| SO5126-3R | Safety connecting plug 4mm with tap (2x), black, 1000V/32A CAT II |
| SO5126-3V | Safety connecting plug 4mm with tap (2x), blue, 1000V/32A CAT II |
| SO5126-3W | Safety connecting plug 4mm with tap (2x), green/yellow, 1000V/32A CAT II |
| SO5148-1L | Set of safety measurement cables, 4mm (31 leads) |
| SO5126-8A | Safety measurement cable 4mm, 25cm/10", red, 600V CAT III ~1000V CAT II / 32A |
| SO5126-8B | Safety measurement cable 4mm, 25cm/10", black, 600V CAT III ~1000V CAT II / 32A |
| SO5126-8E | Safety measurement cable 4mm, 25cm/10", blue, 600V CAT III ~1000V CAT II / 32A |
| SO5126-9A | Safety measurement cable 4mm, 100cm/40", blue, 600V CAT III ~1000V CAT II / 32A |
| SO5126-9C | Safety measurement cable 4mm, 100cm/40", gr/ye, 600V CAT III ~1000V CAT II / 32A |
| SO5126-9P | Safety measurement cable 4mm, 150cm/60", green, 600V CAT III ~1000V CAT II / 32A |
| ST7200-7A | SybaPro experiment trolley, 3-level, 6 sockets, 1250x1970x800mm |
| ST8010-4T | Monitor holder for flat screen monitor of weight up to 15kg / 33lbs |
| ST7200-5L | Protection cover for three-level experiment trolleys |
| ST8010-4G | Keyboard adapter for flat screen monitor holders |
| ST8008-8N | Protected power distribution for working stations |
| ST8010-4J | Multiple socket outlet, 6 fold, with illuminated switch |
| ST8000-4B | Display for Microgrid equipment |
| CO3301-5W | Multifunktionsrelais, Leistungsregler, cos-phi Regler, Synchronisiergerät |
| CO3301-5P | Power switch module |
| SO2800-3X | Interactive Lab Assistant: Control of stand-alone networks with Micro Grid |
| SE2682-5Q | Three-phase synchronous machine with smooth core rotor, 1kW |
| CO3301-5G | Exciter voltage controller with de-excitation |
| CO3212-1P | Motor protection switch, 3 pole, 1.8-2.5A |
| CO3301-5L | HMI (Human Machine Interface) for generators |
| ST8010-4J | Multiple socket outlet, 6 fold, with illuminated switch |
| CO3636-6Y | Servo machine test stand for 1kW machines incl. software ActiveServo (D,GB,F,E) |
| SE2662-7D | Coupling guard with LED lighting for 1kW machines |
| SE2662-6A | Rubber coupling sleeve, 1kW |
| SO5126-3R | Safety connecting plug 4mm with tap (2x), black, 1000V/32A CAT II |
| SO5126-3V | Safety connecting plug 4mm with tap (2x), blue, 1000V/32A CAT II |
| SO5126-3W | Safety connecting plug 4mm with tap (2x), green/yellow, 1000V/32A CAT II |
| SO5148-1L | Set of safety measurement cables, 4mm (31 leads) |
| SO5148-1Z | Set of safety measurement cables, 4mm, 10m, 5 pcs, incl. fastening |
| ST7200-7A | SybaPro experiment trolley, 3-level, 6 sockets, 1250x1970x800mm |
| ST8010-4T | Monitor holder for flat screen monitor of weight up to 15kg / 33lbs |
| ST7200-5L | Protection cover for three-level experiment trolleys |
| ST8010-4G | Keyboard adapter for flat screen monitor holders |
| ST8008-8N | Protected power distribution for working stations |
| ST8010-4J | Multiple socket outlet, 6 fold, with illuminated switch |
| ST8000-4B | Display for Microgrid equipment |
| Add-on | |
| CO3301-6D | HVDC Inverter Station 1 |
| CO3301-6E | HVDC Inverter Station 2 |
| CO3301-6F | HVDC Transmission line Model 300km / 186miles |
| CO3301-3F | Variable Ohmic load, three-phase, 1kW |
| SO2800-3F | Interactive Lab Assistant: Gleichstromübertragung (HVDC) |
| CO3208-3A | Control unit for wind turbine, double-fed asynchronous generator |
| SE2682-6W | Three-phase multi-function machine, 1.0kW |
| CO3208-3B | 3-phase isolation transformer, 1kW for wind power plants |
| SE2682-5T | Incremental position encoder 1024 pulses |
| SE2662-6A | Rubber coupling sleeve, 1kW |
| SE2662-7D | Coupling guard with LED lighting for 1kW machines |
| SO2800-3R | Interactive Lab Assistant: Windkraftanlagen mit DFIG |
| CO5127-2A | Power-Multimeter |
| CO3212-5V | Three-phase power supply with motor protection switch |
| CO5127-2S | Power Quality Meter mit Grafikdisplay und Langzeitspeicher |
| CO3301-5P | Power switch module |
| LM9057 | Patch cable Cat5E 1x 1m yellow, 2x 2m yellow |
| LM8257 | USB 2.0 Ethernet adapter, 10/100 |
| LM9988 | 5-Port Ethernet Switch |
| SO5148-1Z | Set of safety measurement cables, 4mm, 10m, 5 pcs, incl. fastening |
| CO3636-6Y | Servo machine test stand for 1kW machines incl. software ActiveServo (D,GB,F,E) |
| SE2662-7D | Coupling guard with LED lighting for 1kW machines |
| SE2662-6A | Rubber coupling sleeve, 1kW |
| SO5126-3R | Safety connecting plug 4mm with tap (2x), black, 1000V/32A CAT II |
| SO5126-3W | Safety connecting plug 4mm with tap (2x), green/yellow, 1000V/32A CAT II |
| SO5126-3V | Safety connecting plug 4mm with tap (2x), blue, 1000V/32A CAT II |
| SO5148-1L | Set of safety measurement cables, 4mm (31 leads) |
| ST7200-7A | SybaPro experiment trolley, 3-level, 6 sockets, 1250x1970x800mm |
| ST8010-4T | Monitor holder for flat screen monitor of weight up to 15kg / 33lbs |
| ST7200-5L | Protection cover for three-level experiment trolleys |
| ST8010-4G | Keyboard adapter for flat screen monitor holders |
| ST8008-8N | Protected power distribution for working stations |
| ST8010-4J | Multiple socket outlet, 6 fold, with illuminated switch |
| ST8000-4D | Display for Wind Power Plants equipment |
| CO3208-4P | Solar panel emulator, 1.5 kW, 500 V |
| CO3208-1Q | 3-phase industrial photovoltaic inverter |
| CO3301-3F | Variable Ohmic load, three-phase, 1kW |
| SO2800-6V | Interactive Lab Assistant: Photovoltaikanlagen - Professional |
| CO5127-2S | Power Quality Meter mit Grafikdisplay und Langzeitspeicher |
| CO3212-5V | Three-phase power supply with motor protection switch |
| CO3301-5P | Power switch module |
| SO5148-1Z | Set of safety measurement cables, 4mm, 10m, 5 pcs, incl. fastening |
| LM9057 | Patch cable Cat5E 1x 1m yellow, 2x 2m yellow |
| LM8257 | USB 2.0 Ethernet adapter, 10/100 |
| LM9988 | 5-Port Ethernet Switch |
| ST8010-4J | Multiple socket outlet, 6 fold, with illuminated switch |
| SO5126-3R | Safety connecting plug 4mm with tap (2x), black, 1000V/32A CAT II |
| SO5126-3W | Safety connecting plug 4mm with tap (2x), green/yellow, 1000V/32A CAT II |
| SO5126-3V | Safety connecting plug 4mm with tap (2x), blue, 1000V/32A CAT II |
| SO5148-1L | Set of safety measurement cables, 4mm (31 leads) |
| ST7200-7A | SybaPro experiment trolley, 3-level, 6 sockets, 1250x1970x800mm |
| ST8010-4T | Monitor holder for flat screen monitor of weight up to 15kg / 33lbs |
| ST7200-5L | Protection cover for three-level experiment trolleys |
| ST8010-4G | Keyboard adapter for flat screen monitor holders |
| ST8008-8N | Protected power distribution for working stations |
| ST8010-4J | Multiple socket outlet, 6 fold, with illuminated switch |
| ST8000-4G | Display for Photovoltaic Professional equipment |
| SO2800-3V | Interactive Lab Assistant: Pumpspeicherkraftwerk |
| SO2800-3W | Interactive Lab Assistant: Power Plants |
| CO3301-5W | Multifunktionsrelais, Leistungsregler, cos-phi Regler, Synchronisiergerät |
| SO2800-3T | Interactive Lab Assistant: Netzsynchronisation und Generatorregelung |
| SE2682-5Q | Three-phase synchronous machine with smooth core rotor, 1kW |
| CO3301-5G | Exciter voltage controller with de-excitation |
| CO3212-1P | Motor protection switch, 3 pole, 1.8-2.5A |
| CO3301-5L | HMI (Human Machine Interface) for generators |
| CO3301-3F | Variable Ohmic load, three-phase, 1kW |
| CO3301-3E | Capacitive load, three-phase, 1kW |
| CO3301-3D | Inductive load, three-phase, 1kW |
| CO3301-5P | Power switch module |
| CO5127-2S | Power Quality Meter mit Grafikdisplay und Langzeitspeicher |
| CO3212-5V | Three-phase power supply with motor protection switch |
| SO5148-1Z | Set of safety measurement cables, 4mm, 10m, 5 pcs, incl. fastening |
| LM9057 | Patch cable Cat5E 1x 1m yellow, 2x 2m yellow |
| LM8257 | USB 2.0 Ethernet adapter, 10/100 |
| LM9988 | 5-Port Ethernet Switch |
| ST8010-4J | Multiple socket outlet, 6 fold, with illuminated switch |
| CO3636-6Y | Servo machine test stand for 1kW machines incl. software ActiveServo (D,GB,F,E) |
| SE2662-7D | Coupling guard with LED lighting for 1kW machines |
| SE2662-6A | Rubber coupling sleeve, 1kW |
| SO5126-3R | Safety connecting plug 4mm with tap (2x), black, 1000V/32A CAT II |
| SO5126-3V | Safety connecting plug 4mm with tap (2x), blue, 1000V/32A CAT II |
| SO5126-3W | Safety connecting plug 4mm with tap (2x), green/yellow, 1000V/32A CAT II |
| SO5148-1L | Set of safety measurement cables, 4mm (31 leads) |
| SO5126-8L | Safety measurement cable 4mm, 50cm/20", black, 600V CAT III ~1000V CAT II / 32A |
| SO5126-9J | Safety measurement cable 4mm, 150cm/60", brown, 600V CAT III ~1000V CAT II / 32A |
| SO5126-9G | Safety measurement cable 4mm, 150cm/60", black, 600V CAT III ~1000V CAT II / 32A |
| SO5126-9N | Safety measurement cable 4mm, 150cm/60", grey, 600V CAT III ~1000V CAT II / 32A |
| SO5126-9K | Safety measurement cable 4mm, 150cm/60", blue, 600V CAT III ~1000V CAT II / 32A |
| ST7200-7A | SybaPro experiment trolley, 3-level, 6 sockets, 1250x1970x800mm |
| ST8010-4T | Monitor holder for flat screen monitor of weight up to 15kg / 33lbs |
| ST7200-5L | Protection cover for three-level experiment trolleys |
| ST8010-4G | Keyboard adapter for flat screen monitor holders |
| ST8008-8N | Protected power distribution for working stations |
| ST8010-4J | Multiple socket outlet, 6 fold, with illuminated switch |
| ST8000-4K | Display for Pump Storage Power Plant equipment |
| CO3301-3F | Variable Ohmic load, three-phase, 1kW |
| CO3301-3E | Capacitive load, three-phase, 1kW |
| CO3301-3D | Inductive load, three-phase, 1kW |
| CO3301-5P | Power switch module |
| SO2800-3Y | Interactive Lab Assistant: Energy management |
| CO5127-2S | Power Quality Meter mit Grafikdisplay und Langzeitspeicher |
| CO3301-3Z | Adjustable 3-phase power supply, 0-450V/2A |
| SO5148-1Z | Set of safety measurement cables, 4mm, 10m, 5 pcs, incl. fastening |
| LM9057 | Patch cable Cat5E 1x 1m yellow, 2x 2m yellow |
| LM9988 | 5-Port Ethernet Switch |
| LM8257 | USB 2.0 Ethernet adapter, 10/100 |
| SO5126-3R | Safety connecting plug 4mm with tap (2x), black, 1000V/32A CAT II |
| SO5126-3V | Safety connecting plug 4mm with tap (2x), blue, 1000V/32A CAT II |
| SO5126-3W | Safety connecting plug 4mm with tap (2x), green/yellow, 1000V/32A CAT II |
| SO5148-1L | Set of safety measurement cables, 4mm (31 leads) |
| ST7200-7A | SybaPro experiment trolley, 3-level, 6 sockets, 1250x1970x800mm |
| ST8010-4T | Monitor holder for flat screen monitor of weight up to 15kg / 33lbs |
| ST7200-5L | Protection cover for three-level experiment trolleys |
| ST8010-4G | Keyboard adapter for flat screen monitor holders |
| ST8008-8N | Protected power distribution for working stations |
| ST8010-4J | Multiple socket outlet, 6 fold, with illuminated switch |
| ST8000-4C | Display for Energy Management equipment |
Learning Content in Detail
Analyzing microgrid operating modes
Configuring automatic synchronization
Controlling voltage and reactive power
Controlling active power and frequency
Integrating photovoltaic systems
Integrating wind turbines
Operating power plants and pumped storage
Carrying out energy management and load control
Configuring generator protection
Controlling processes via SCADA
Features & Applications
- Automatic synchronization and grid control — The CO3301-5W multifunction relay handles automatic synchronization and controls the voltage and frequency of the generator module. Students follow the connection process step by step and evaluate the control quality.
- Switching operating modes during the experiment — Island operation, parallel island operation and grid-parallel operation can be switched seamlessly. This allows students to reproduce real grid structures and see immediately how system behavior changes with the operating mode.
- Integrating renewable generators from PV and wind — Photovoltaics and wind turbines with doubly fed induction generators can be fully integrated into the microgrid and controlled dynamically.
- Integrating power plants and pumped storage — Conventional types of power plant and pumped-storage power plants are simulated. Students use them to investigate peak load control and frequency stabilization in the interconnected grid.
- Energy management with complex loads — Resistive, inductive and capacitive loads reproduce real consumer profiles. They form the basis for practical experiments on reactive power compensation and peak load monitoring.
- Real-time visualization and SCADA control — The SCADA for Power Engineering Lab software monitors, controls and evaluates all grid parameters centrally and in real time.
- System protection and monitoring functions — Integrated protection functions guard against overload, unbalanced load, ground faults and overcurrent, as well as voltage and frequency deviations.
- Multifunction relay CO3301-5W — Handles automatic synchronization, active and reactive power sharing and comprehensive generator protection in the microgrid.
- Photovoltaics via grid inverter (EPH32PT) — Reproduces the infeed and derating of PV power, allowing students to stabilize the voltage and the grid under changing irradiance.
- Wind turbine with DFIG (EWG11PT) — Integrates variable-speed doubly fed induction generators, which students use to investigate feed-in management and reactive power control.
- Power plant emulation and pumped storage (EUK11PT) — Simulates the operation of different types of power plant and of pumped storage for frequency control and the provision of balancing power.
- Three-phase R/L/C load modules (EUC11PT) — Provide continuously and incrementally adjustable resistive, inductive and capacitive loads for reproducing real consumer profiles.
- SCADA for Power Engineering Lab — Displays the grid symbolically, records all measured values in real time, controls the system automatically and records load profiles.
- Industrial software for the multifunction relay — Used for remote maintenance, parameterization and fault diagnosis of the CO3301-5W multifunction relay directly from the PC.
- Solar Panel, WindSim and ActiveServo — Solar Panel sets irradiance, partial shading and the sun’s path and imports real solar profiles. WindSim generates wind profiles, adjusts the pitch angle and sets active and reactive power. ActiveServo records machine characteristics and defines load profiles.

From Knowledge Comes Capability.
You guide the learning
Where theory and practice go hand in hand.
RXLea brings a new way of learning: project-based, hands-on and clearly structured. Learners solve real-world tasks, while instructors save time on preparation. Interactive modules, smart analytics and real hardware create a modern, efficient learning world.
Hands-on and interactive
Animations, interactive tasks and realistic scenarios build a deep understanding. All content is organized into clear learning paths for focused, hands-on learning.
Digital support
3D assembly animations and digital instructions simplify complex procedures, reduce errors and help learners work more independently.
Visual support
Overview graphics, screenshots and sample animations make the learning world transparent. Photos from the learning packages are also available, including country-specific versions where needed.




Stay ahead in
technical training.
Get the latest training systems, product launches and educational insights, delivered directly to your inbox.