High-Voltage Direct Current Transmission (HVDC) with FRT
High-Voltage Direct Current Transmission (HVDC) with FRT
Modular panel system for HVDC: students parameterize two converter stations, emulate symmetrical and asymmetrical grid faults and evaluate the fault ride-through behavior by measurement.
- Evaluating fault ride-through behavior by measurement
- Evaluating transients during grid faults in real time
- Emulating grid faults with configurable parameters
- Dynamic reactive power support
- Evaluating symmetrical components
Offshore wind farms and remote generators can be connected with lower losses via direct current than via three-phase AC. For grid operation, what matters is how an HVDC link behaves when the voltage sags. The modular system replicates this link in full: two converter stations with controllers for the DC link and load flow, a line model for 300 km and an adjustable grid fault simulator. Students set the duration and depth of the voltage sag, record the transients and break the signals down into positive-, negative- and zero-sequence components. They control capacitive and inductive reactive power during the fault and test the requirements of international grid codes in experiments.
| Base Product | |
| CO3208-3C | Dynamic grid fault simulator |
| CO3301-6D | HVDC Inverter Station 1 |
| CO3301-6E | HVDC Inverter Station 2 |
| CO3301-6F | HVDC Transmission line Model 300km / 186miles |
| CO3301-3F | Variable Ohmic load, three-phase, 1kW |
| SO2800-3F | Interactive Lab Assistant: Gleichstromübertragung (HVDC) |
| Power Supply | |
| CO3301-3Z | Adjustable 3-phase power supply, 0-450V/2A |
| CO3212-5V | Three-phase power supply with motor protection switch |
| Accessories | |
| ST8010-4J | Multiple socket outlet, 6 fold, with illuminated switch |
| Furniture | |
| ST7200-7A | SybaPro experiment trolley, 3-level, 6 sockets, 1250x1970x800mm |
| ST8010-4T | Monitor holder for flat screen monitor of weight up to 15kg / 33lbs |
| ST7200-5L | Protection cover for three-level experiment trolleys |
| ST8010-4G | Keyboard adapter for flat screen monitor holders |
| ST8008-8N | Protected power distribution for working stations |
| ST8010-4J | Multiple socket outlet, 6 fold, with illuminated switch |
| Furniture Accessories | |
| ST8000-4M | Display for HVDC equipment |
| Measurement Leads | |
| SO5126-3R | Safety connecting plug 4mm with tap (2x), black, 1000V/32A CAT II |
| SO5126-3V | Safety connecting plug 4mm with tap (2x), blue, 1000V/32A CAT II |
| SO5126-3U | Safety connecting plug 4mm with tap (2x), red, 1000V/32A CAT II |
| SO5126-3W | Safety connecting plug 4mm with tap (2x), green/yellow, 1000V/32A CAT II |
| SO5148-1L | Set of safety measurement cables, 4mm (31 leads) |
Learning Content in Detail
Evaluating fault ride-through behavior by measurement
Features & Applications
- Evaluating transients during grid faults in real time — Students precisely record what happens during a fault, evaluate dynamic voltage sags and derive measures for active grid support.
- Emulating grid faults with configurable parameters — The duration and depth of the voltage sag can be set freely. Students generate symmetrical and asymmetrical faults and use them to investigate the behavior of the inverters.
- Dynamic reactive power support — Students control capacitive and inductive reactive power during the fault, thereby actively stabilizing the grid, and test the requirements of international grid codes.
- Evaluating symmetrical components — On the virtual monitor, students break down the signals of asymmetrical faults into positive-, negative- and zero-sequence components and analyze the effect of negative-sequence control.
- Adjustable grid fault simulator (CO3208-3C) — The fault duration can be adjusted from 50 to 2000 ms and the sag depth from 0 to 100%. Students use it to test the stability limits of the system and compare controller settings under extreme conditions.
- HVDC converter stations (CO3301-6D, CO3301-6E) — The modules control the DC link up to 750 V DC and the load flow. Students parameterize them in rectifier, inverter or STATCOM mode.
- HVDC line model 300 km (CO3301-6F) — The module replicates the resistance (7.2 ohms) and inductance (230 mH) of a 300 km overhead line at a scale of 1:1000. This makes line losses over long distances measurable.
- Virtual FRT monitor — Students analyze the positive- and negative-sequence components of currents and voltages in real time and evaluate the transient behavior.

From Knowledge Comes Capability.
You guide the learning
Where theory and practice go hand in hand.
RXLea brings a new way of learning: project-based, hands-on and clearly structured. Learners solve real-world tasks, while instructors save time on preparation. Interactive modules, smart analytics and real hardware create a modern, efficient learning world.
Hands-on and interactive
Animations, interactive tasks and realistic scenarios build a deep understanding. All content is organized into clear learning paths for focused, hands-on learning.
Digital support
3D assembly animations and digital instructions simplify complex procedures, reduce errors and help learners work more independently.
Visual support
Overview graphics, screenshots and sample animations make the learning world transparent. Photos from the learning packages are also available, including country-specific versions where needed.