Overcurrent Time Protection for Lines
Overcurrent Time Protection for Lines
Equipment set for time-overcurrent protection: students parameterize an industrial protective relay on a three-phase line model, create specific short circuits and measure pick-up values and tripping times.
- Dimensioning and parameterizing time-overcurrent protection
- Determining the reset ratio
- Determining the minimum tripping time
- Checking circuit breaker tripping
- Creating short circuits safely
- Original industrial protective relay
- Parameterization via SCADA or by hand
- Electrically isolated transmission via RS485
Medium-voltage and high-voltage grids are monitored by protective devices via current and voltage transformers. Within this system, time-overcurrent protection provides selective overload and short-circuit protection for radial networks fed from one end: a current well above the operating current causes the relay to pick up, and after the time delay has elapsed, the output relay operates the circuit breaker. The equipment set covers this entire chain, from the variable three-phase power supply and the line model for 150 km or 300 km to the circuit breaker. Students create specific short circuits, determine the reset ratio and minimum tripping time and parameterize the relay by hand or on the PC via the RS485 interface.
| Base Product | |
| CO3301-4J | Überstromzeitrelais |
| CO3301-3A | Transmission line Model 150km/300km (93.2miles/186.4miles) |
| CO3301-3F | Variable Ohmic load, three-phase, 1kW |
| CO3301-5P | Power switch module |
| SO2800-6L | Interactive Lab Assistant: Protective systems for high-voltage transmission line |
| Software | |
| SO4001-3H | Software SCADA Viewer |
| Power Supply | |
| CO3301-3Z | Adjustable 3-phase power supply, 0-450V/2A |
| Measuring Instruments | |
| CO5127-2S | Power Quality Meter mit Grafikdisplay und Langzeitspeicher |
| LM2330 | Multi13S digital multimeter |
| Accessories | |
| LM9057 | Patch cable Cat5E 1x 1m yellow, 2x 2m yellow |
| LM8257 | USB 2.0 Ethernet adapter, 10/100 |
| LM9988 | 5-Port Ethernet Switch |
| ST8010-4J | Multiple socket outlet, 6 fold, with illuminated switch |
| LM9025 | Interface converter USB/RS485 |
| Furniture | |
| ST7200-7A | SybaPro experiment trolley, 3-level, 6 sockets, 1250x1970x800mm |
| ST8010-4T | Monitor holder for flat screen monitor of weight up to 15kg / 33lbs |
| ST7200-5L | Protection cover for three-level experiment trolleys |
| ST8010-4G | Keyboard adapter for flat screen monitor holders |
| Furniture Accessories | |
| ST8000-4L | Display for Power Transmission equipment |
| Measurement Leads | |
| SO5126-3R | Safety connecting plug 4mm with tap (2x), black, 1000V/32A CAT II |
| SO5126-3V | Safety connecting plug 4mm with tap (2x), blue, 1000V/32A CAT II |
| SO5126-3W | Safety connecting plug 4mm with tap (2x), green/yellow, 1000V/32A CAT II |
| SO5148-1L | Set of safety measurement cables, 4mm (31 leads) |
Learning Content in Detail
Dimensioning and parameterizing time-overcurrent protection
Determining the reset ratio
Determining the minimum tripping time
Checking circuit breaker tripping
Features & Applications
- Creating short circuits safely — Students deliberately trigger short circuits and use them to test the tripping stages of the protective relay. Users and equipment remain protected at all times.
- Original industrial protective relay — The protective relays used come from manufacturers operating worldwide and are the same as those installed in real systems.
- Parameterization via SCADA or by hand — The relay can be set either directly on the device or on the PC via the integrated RS485 interface.
- Electrically isolated transmission via RS485 — An optical link captures the values and transmits them from the relay to the PC with electrical isolation.
- Time-overcurrent relay (CO3301-4J) — This three-phase relay detects overloads and can be configured for definite-time (DMT) or inverse-time (IDMT) overcurrent protection with three inverse characteristics.
- Line model 150 km / 300 km (CO3301-3A) — This three-phase model of a high-voltage overhead line allows measurements under no-load, matched-load and short-circuit conditions.
- Circuit breaker module (CO3301-5P) — The module switches the voltage on and off manually or by remote control. Indicator lamps show the operating status.
- Variable resistive load (CO3301-3F) — Three synchronously adjustable toroidal rheostats allow parallel, series, wye and delta connections of up to 1 kW.
- Variable three-phase power supply 0–450 V / 2 A (CO3301-3Z) — This infinitely variable power supply with variable transformer and motor protection circuit breaker supplies the system safely.
- SCADA Viewer — The software controls and monitors the system. Measured values are displayed, recorded and evaluated in real time.

From Knowledge Comes Capability.
You guide the learning
Where theory and practice go hand in hand.
RXLea brings a new way of learning: project-based, hands-on and clearly structured. Learners solve real-world tasks, while instructors save time on preparation. Interactive modules, smart analytics and real hardware create a modern, efficient learning world.
Hands-on and interactive
Animations, interactive tasks and realistic scenarios build a deep understanding. All content is organized into clear learning paths for focused, hands-on learning.
Digital support
3D assembly animations and digital instructions simplify complex procedures, reduce errors and help learners work more independently.
Visual support
Overview graphics, screenshots and sample animations make the learning world transparent. Photos from the learning packages are also available, including country-specific versions where needed.




Stay ahead in
technical training.
Get the latest training systems, product launches and educational insights, delivered directly to your inbox.