EUL81PT

Expansion set for load-dependent voltage control: students control a motor-driven three-phase variable transformer manually and automatically via SCADA and the Power Quality Meter.

Learning Content
  • Investigating how the VRDT works
  • Determining no-load and short-circuit behavior
  • Analyzing the voltage profile along the line
  • Setting the voltage manually
KEY FEATURES
  • Voltage-regulated distribution transformer (VRDT)
  • Motor-driven variable transformer
  • Manual and automatic control
  • Integrated smart grid control
Speak with a Product Specialist +1 (757) 808-5696 · sales@lucas-nuelle.com

Distributed infeed from photovoltaics causes voltage fluctuations in low-voltage grids. Voltage-regulated distribution transformers compensate for this by adjusting their transformation ratio to the load conditions. This expansion set combines a motor-driven three-phase variable transformer in autotransformer connection with a line model, loads and a Power Quality Meter. Students first investigate the control range and the no-load and short-circuit behavior of the autotransformer. They then connect loads and observe the voltage drop along the line. First they readjust the voltage manually using pushbuttons, then they set up automatic control: the Power Quality Meter records the actual value and sends the raise and lower commands to the motor drive.

CO3301-3ATransmission line Model 150km/300km (93.2miles/186.4miles)
CO3301-3PThree-phase variable transformer with motor drive
CO3301-3FVariable Ohmic load, three-phase, 1kW
CO3301-3DInductive load, three-phase, 1kW
CO3301-5PPower switch module
SO2800-3LInteractive Lab Assistant: High-voltage transmission lines
SO4001-3HSoftware SCADA Viewer
CO5127-2SPower Quality Meter mit Grafikdisplay und Langzeitspeicher
CO3301-3ZAdjustable 3-phase power supply, 0-450V/2A
LM9057Patch cable Cat5E 1x 1m yellow, 2x 2m yellow
LM8257USB 2.0 Ethernet adapter, 10/100
LM99885-Port Ethernet Switch
ST8010-4JMultiple socket outlet, 6 fold, with illuminated switch
ST7200-7ASybaPro experiment trolley, 3-level, 6 sockets, 1250x1970x800mm
ST8010-4TMonitor holder for flat screen monitor of weight up to 15kg / 33lbs
ST7200-5LProtection cover for three-level experiment trolleys
ST8010-4GKeyboard adapter for flat screen monitor holders
ST8000-4LDisplay for Power Transmission equipment
SO5126-3RSafety connecting plug 4mm with tap (2x), black, 1000V/32A CAT II
SO5126-3VSafety connecting plug 4mm with tap (2x), blue, 1000V/32A CAT II
SO5126-3WSafety connecting plug 4mm with tap (2x), green/yellow, 1000V/32A CAT II
SO5148-1LSet of safety measurement cables, 4mm (31 leads)
SO5126-8BSafety measurement cable 4mm, 25cm/10", black, 600V CAT III ~1000V CAT II / 32A
SO5126-8LSafety measurement cable 4mm, 50cm/20", black, 600V CAT III ~1000V CAT II / 32A

Learning Content in Detail

Students work through voltage control, from the control range of the transformer to setting up automatic operation in the grid.

Investigating how the VRDT works

Students determine the control range of the three-phase variable transformer in autotransformer connection.

Determining no-load and short-circuit behavior

Students record the characteristic curves of the autotransformer under various operating conditions.

Analyzing the voltage profile along the line

Students investigate the voltage behavior on the line model with changing load currents.

Setting the voltage manually

Students readjust the output voltage by hand using pushbuttons.

Setting up automatic voltage control

Students configure and test the control system via SCADA and the Power Quality Meter.

Features & Applications

The experiments follow the tasks in the distribution grid: compensating for voltage fluctuations caused by distributed infeed and load changes, using voltage-regulated distribution transformers in the smart grid and setting the voltage both manually and automatically.
  • Voltage-regulated distribution transformer (VRDT) — The system replicates the compensation of voltage fluctuations in the local distribution grid under changing infeed and load conditions.
  • Motor-driven variable transformer — The variable transformer adjusts the voltage from 0 to 450 V via control inputs.
  • Manual and automatic control — Students can either control the voltage by hand using pushbuttons or have it adjusted fully automatically via SCADA.
  • Integrated smart grid control — The Power Quality Meter records the actual value and sends the raise and lower commands to the transformer’s motor drive.
  • Three-phase variable transformer (CO3301-3P) — This variable transformer in autotransformer connection is rated at 1000 VA in vector group Yan0 and has 24 V inputs for raising and lowering the voltage.
  • Line model 150 km/300 km (CO3301-3A) — This three-phase 380 kV overhead line model replicates the voltage drop along the line under load.
  • Power Quality Meter (CO5127-1S) — The meter records the grid voltage at the end of the line and sends switching signals to the transformer’s motor control.
  • Load modules up to 1 kW — Three separate modules for resistive, inductive and capacitive loads allow wye, delta, series and parallel connections.
  • SCADA for PowerLab software — The software visualizes the voltage control in the digital circuit diagram and automatically controls the transformer within the specified setpoint range.
Learners working with RXLea on a tablet at a Lucas-Nuelle training system
RXLea

From Knowledge Comes Capability.

You guide the learning

Where theory and practice go hand in hand.

RXLea brings a new way of learning: project-based, hands-on and clearly structured. Learners solve real-world tasks, while instructors save time on preparation. Interactive modules, smart analytics and real hardware create a modern, efficient learning world.

Hands-on and interactive

Animations, interactive tasks and realistic scenarios build a deep understanding. All content is organized into clear learning paths for focused, hands-on learning.

Digital support

3D assembly animations and digital instructions simplify complex procedures, reduce errors and help learners work more independently.

Visual support

Overview graphics, screenshots and sample animations make the learning world transparent. Photos from the learning packages are also available, including country-specific versions where needed.

Learners using a tablet at an energy training system
RXLea on desktop, laptop and tablet
RXLea Path Creator for building learning journeys
RXLea Navigator showing the learning world
Learn more about RXLea
Newsletter

Stay ahead in
technical training.

Get the latest training systems, product launches and educational insights, delivered directly to your inbox.

Your email address

By subscribing, you agree to our Privacy Policy. You can unsubscribe at any time.

 Please select at least one category before subscribing.
I'm interested in - select all that apply