Skip to content

Combined Networks of Cables and Lines

RXLea
Digital projects for hands-on learningInteractive learning content, directly connected to the training system.

Combined Networks of Cables and Lines

EUL61PT

Expansion set for mixed transmission lines: students measure the power flow and losses of an overhead line, transformer substation and underground cable, both individually and combined.

Learning Content
  • Comparing cables and overhead lines
  • Investigating transmission line 1
  • Investigating transmission line 2
  • Determining losses in the interconnected grid
KEY FEATURES
  • Investigating combined transmission lines
  • Determining the losses of individual grid components
  • Interface analysis via transformer substations
  • Measurement at several nodes
Speak with a Product Specialist +1 (757) 808-5696 · sales@lucas-nuelle.com

Real transmission grids rarely consist of a single medium. Overhead lines, transformer substations and underground cables are arranged in series, and each element behaves differently. This expansion set combines a 380 kV overhead line model, a 380 V/110 V transformer substation and a cable model into one continuous transmission line. Students set up the sequence of overhead line, transformer and cable, then reverse it and compare the two cases. Power Quality Meters at the transfer points provide the measured values from which students determine the individual losses of each component. They determine the efficiency and operating behavior of the transformer substation under load and check their model calculations against the measurement results.

CO3301-3CKabelnachbildung 12,5 km / 37,5 km
CO3301-3MConversion station 380 V/110 V
CO3301-3ATransmission line Model 150km/300km (93.2miles/186.4miles)
SO2800-3LInteractive Lab Assistant: High-voltage transmission lines
CO3301-3FVariable Ohmic load, three-phase, 1kW
CO3301-3ECapacitive load, three-phase, 1kW
CO3301-3DInductive load, three-phase, 1kW
CO3301-5PPower switch module
SO4001-3HSoftware SCADA Viewer
CO5127-2SPower Quality Meter mit Grafikdisplay und Langzeitspeicher
CO3301-3ZAdjustable 3-phase power supply, 0-450V/2A
LM9057Patch cable Cat5E 1x 1m yellow, 2x 2m yellow
LM8257USB 2.0 Ethernet adapter, 10/100
LM99885-Port Ethernet Switch
ST8010-4JMultiple socket outlet, 6 fold, with illuminated switch
ST7200-7ASybaPro experiment trolley, 3-level, 6 sockets, 1250x1970x800mm
ST8010-4TMonitor holder for flat screen monitor of weight up to 15kg / 33lbs
ST7200-5LProtection cover for three-level experiment trolleys
ST8010-4GKeyboard adapter for flat screen monitor holders
ST8000-4LDisplay for Power Transmission equipment
SO5126-3RSafety connecting plug 4mm with tap (2x), black, 1000V/32A CAT II
SO5126-3VSafety connecting plug 4mm with tap (2x), blue, 1000V/32A CAT II
SO5126-3WSafety connecting plug 4mm with tap (2x), green/yellow, 1000V/32A CAT II
SO5148-1LSet of safety measurement cables, 4mm (31 leads)
SO5126-8BSafety measurement cable 4mm, 25cm/10", black, 600V CAT III ~1000V CAT II / 32A
SO5126-8LSafety measurement cable 4mm, 50cm/20", black, 600V CAT III ~1000V CAT II / 32A

Learning Content in Detail

Students explore the interaction of the grid elements: comparing cables and overhead lines, investigating both sequences and attributing the losses.

Comparing cables and overhead lines

Students compare the operating parameters of the two transmission media.

Investigating transmission line 1

Students analyze the behavior of the sequence overhead line, transformer and cable.

Investigating transmission line 2

Students analyze the behavior of the reverse sequence cable, transformer and overhead line.

Determining losses in the interconnected grid

Students determine the individual losses of the overhead line, transformer and cable section.

Determining the parameters of the transformer substation

Students determine the efficiency, transfer behavior and operating behavior of the transformer under load.

Features & Applications

The experiments follow the structure of real grids: mixed transmission lines made up of overhead lines, transformers and underground cables, the distribution of losses and power in the interconnected grid, and the behavior of the transformer substation at the interface.
  • Investigating combined transmission lines — Students analyze grid structures consisting of overhead lines, transformers and underground cables as a whole.
  • Determining the losses of individual grid components — Real power and power losses can be determined separately for overhead line sections, transformer substations and cable sections.
  • Interface analysis via transformer substations — The transformation from 380 V to 110 V realistically replicates the transfer point between overhead line and underground cable.
  • Measurement at several nodes — Several Power Quality Meters simultaneously record the electrical parameters at the transfer points of the interconnected grid.
  • Cable model (CO3301-3C) — This three-phase underground cable model with values for 12.5 km and 37.5 km represents the cable section of the grid.
  • Transformer substation 380 V/110 V (CO3301-3M) — The 400 VA three-phase transformer with vector group YNyn0 couples the two voltage levels in the interconnected grid.
  • Power Quality Meter (CO5127-1S) — The meters record currents, voltages and power at several points along the combined transmission line.
  • Line model (CO3301-3A) — The model of a 380 kV line represents the overhead line section of the transmission line.
  • SCADA for PowerLab software — The software displays the interconnected grid topologies, for example as diagram EUL_6.pvc, and logs the measured values of all system nodes.
Learners working with RXLea on a tablet at a Lucas-Nuelle training system
RXLea

From Knowledge Comes Capability.

You guide the learning

Where theory and practice go hand in hand.

RXLea brings a new way of learning: project-based, hands-on and clearly structured. Learners solve real-world tasks, while instructors save time on preparation. Interactive modules, smart analytics and real hardware create a modern, efficient learning world.

Hands-on and interactive

Animations, interactive tasks and realistic scenarios build a deep understanding. All content is organized into clear learning paths for focused, hands-on learning.

Digital support

3D assembly animations and digital instructions simplify complex procedures, reduce errors and help learners work more independently.

Visual support

Overview graphics, screenshots and sample animations make the learning world transparent. Photos from the learning packages are also available, including country-specific versions where needed.

Learners using a tablet at an energy training system
RXLea on desktop, laptop and tablet
RXLea Path Creator for building learning journeys
RXLea Navigator showing the learning world
Learn more about RXLea
Newsletter

Stay ahead in
technical training.

Get the latest training systems, product launches and educational insights, delivered directly to your inbox.

Your email address

By subscribing, you agree to our Privacy Policy. You can unsubscribe at any time.

 Please select at least one category before subscribing.
I'm interested in - select all that apply