Transmission Line with Earth-Fault Compensation
Transmission Line with Earth-Fault Compensation
Expansion set with Petersen coil: students investigate single-phase ground faults in networks with an ungrounded neutral and set the arc suppression coil to the appropriate value in nine steps.
- Measuring behavior during a ground fault
- Compensating the ground-fault current
- Calculating asymmetrical faults
- Assessing safety in the distribution grid
- Simulating ungrounded neutral points
- Stepped ground-fault compensation
- Realistic behavior during asymmetrical faults
- Comprehensive grid monitoring
In the distribution grid, a ground fault on a phase conductor must not lead to immediate disconnection. To keep the fault current at the fault location low, a Petersen coil compensates the capacitive component. This expansion set adds a ground-fault compensation unit with nine inductance steps between 1.0 and 2.0 H to the line model. Students set up a network with an ungrounded neutral, create single-phase ground faults and measure the neutral point displacement voltage and the currents at the fault location. They then tune the arc suppression coil and observe how the ground-fault current decreases. The Power Quality Meters display zero-sequence voltages and currents, and SCADA for PowerLab shows the phasor diagrams in real time.
| Base Product | |
| CO3301-4X | Earth fault compensation unit |
| CO3301-3A | Transmission line Model 150km/300km (93.2miles/186.4miles) |
| SO2800-3L | Interactive Lab Assistant: High-voltage transmission lines |
| CO3301-3F | Variable Ohmic load, three-phase, 1kW |
| CO3301-3E | Capacitive load, three-phase, 1kW |
| CO3301-3D | Inductive load, three-phase, 1kW |
| CO3301-5P | Power switch module |
| Software | |
| SO4001-3H | Software SCADA Viewer |
| Measuring Instruments | |
| CO5127-2S | Power Quality Meter mit Grafikdisplay und Langzeitspeicher |
| CO3301-3Z | Adjustable 3-phase power supply, 0-450V/2A |
| Accessories | |
| LM9057 | Patch cable Cat5E 1x 1m yellow, 2x 2m yellow |
| LM8257 | USB 2.0 Ethernet adapter, 10/100 |
| LM9988 | 5-Port Ethernet Switch |
| ST8010-4J | Multiple socket outlet, 6 fold, with illuminated switch |
| Furniture | |
| ST7200-7A | SybaPro experiment trolley, 3-level, 6 sockets, 1250x1970x800mm |
| ST8010-4T | Monitor holder for flat screen monitor of weight up to 15kg / 33lbs |
| ST7200-5L | Protection cover for three-level experiment trolleys |
| ST8010-4G | Keyboard adapter for flat screen monitor holders |
| Furniture Accessories | |
| ST8000-4L | Display for Power Transmission equipment |
| Measurement Leads | |
| SO5126-3R | Safety connecting plug 4mm with tap (2x), black, 1000V/32A CAT II |
| SO5126-3V | Safety connecting plug 4mm with tap (2x), blue, 1000V/32A CAT II |
| SO5126-3W | Safety connecting plug 4mm with tap (2x), green/yellow, 1000V/32A CAT II |
| SO5148-1L | Set of safety measurement cables, 4mm (31 leads) |
| SO5126-8B | Safety measurement cable 4mm, 25cm/10", black, 600V CAT III ~1000V CAT II / 32A |
| SO5126-8L | Safety measurement cable 4mm, 50cm/20", black, 600V CAT III ~1000V CAT II / 32A |
Learning Content in Detail
Measuring behavior during a ground fault
Compensating the ground-fault current
Calculating asymmetrical faults
Assessing safety in the distribution grid
Features & Applications
- Simulating ungrounded neutral points — Students analyze three-phase systems without neutral point grounding, both in normal operation and under fault conditions.
- Stepped ground-fault compensation — The arc suppression coil can be adjusted in nine steps from 1.0 to 2.0 H and can thus be adapted to different grid conditions.
- Realistic behavior during asymmetrical faults — Students test single-phase short circuits with ground contact and evaluate the currents at the fault location.
- Comprehensive grid monitoring — Digital Power Quality Meters record voltage and current vectors in real time and make the effect of compensation visible.
- Ground-fault compensation unit (CO3301-4X) — The Petersen coil operates at a rated voltage of 230 V and a maximum of 0.5 A. Nine inductance steps between 1.0 and 2.0 H are available.
- Line model (CO3301-3A) — The model of a 380 kV line generates realistic capacitive ground-fault currents, providing the basis for compensation.
- Power Quality Meter (CO5127-1S) — The meter records asymmetries in the three-phase system, including zero-sequence voltages and currents during ground faults.
- Load modules up to 1 kW — Three separate modules for resistive, inductive and capacitive loads allow wye, delta, series and parallel connections.
- Circuit breaker module (CO3301-5P) — It switches the 400 V supply voltage on and off during the experiments, either manually or by electrical remote control.
- SCADA for PowerLab — The software displays the asymmetrical fault currents and the compensating effect of the Petersen coil as a phasor diagram in real time.

From Knowledge Comes Capability.
You guide the learning
Where theory and practice go hand in hand.
RXLea brings a new way of learning: project-based, hands-on and clearly structured. Learners solve real-world tasks, while instructors save time on preparation. Interactive modules, smart analytics and real hardware create a modern, efficient learning world.
Hands-on and interactive
Animations, interactive tasks and realistic scenarios build a deep understanding. All content is organized into clear learning paths for focused, hands-on learning.
Digital support
3D assembly animations and digital instructions simplify complex procedures, reduce errors and help learners work more independently.
Visual support
Overview graphics, screenshots and sample animations make the learning world transparent. Photos from the learning packages are also available, including country-specific versions where needed.