Three-phase model of a 380 kV transmission line. Students measure resistances and reactances and analyze no-load, matched-load and short-circuit conditions for line lengths of 150 km and 300 km.

Learning Content
  • Determining line parameters
  • Investigating the line under no-load conditions
  • Evaluating the line under matched-load conditions
  • Recording short-circuit behavior
KEY FEATURES
  • Realistic line model
  • Automatic length switching
  • Comprehensive load analyses
  • Integrated PC-based data acquisition
Speak with a Product Specialist +1 (757) 808-5696 · sales@lucas-nuelle.com

Large amounts of power are transmitted over overhead lines at the high-voltage and extra-high-voltage levels. How such a line behaves cannot be measured on the real installation. This equipment set replicates a 380 kV line at a voltage and current scale of 1:1000, with lumped elements for resistance, inductance, and line-to-line and line-to-ground capacitance. Using overlay masks, students switch between line lengths of 150 km and 300 km. They measure the line parameters, investigate no-load, matched-load and short-circuit conditions and load the line with resistive, inductive and capacitive loads. Finally, they determine transmission losses, size a reactive power compensation system and evaluate the efficiency.

CO3301-3ATransmission line Model 150km/300km (93.2miles/186.4miles)
SO2800-3LInteractive Lab Assistant: High-voltage transmission lines
CO3301-3FVariable Ohmic load, three-phase, 1kW
CO3301-3ECapacitive load, three-phase, 1kW
CO3301-3DInductive load, three-phase, 1kW
CO3301-5PPower switch module
SO4001-3HSoftware SCADA Viewer
CO5127-2SPower Quality Meter mit Grafikdisplay und Langzeitspeicher
CO3301-3ZAdjustable 3-phase power supply, 0-450V/2A
LM9057Patch cable Cat5E 1x 1m yellow, 2x 2m yellow
LM8257USB 2.0 Ethernet adapter, 10/100
LM99885-Port Ethernet Switch
ST8010-4JMultiple socket outlet, 6 fold, with illuminated switch
ST7200-7ASybaPro experiment trolley, 3-level, 6 sockets, 1250x1970x800mm
ST8010-4TMonitor holder for flat screen monitor of weight up to 15kg / 33lbs
ST7200-5LProtection cover for three-level experiment trolleys
ST8010-4GKeyboard adapter for flat screen monitor holders
ST8000-4LDisplay for Power Transmission equipment
SO5126-3RSafety connecting plug 4mm with tap (2x), black, 1000V/32A CAT II
SO5126-3VSafety connecting plug 4mm with tap (2x), blue, 1000V/32A CAT II
SO5126-3WSafety connecting plug 4mm with tap (2x), green/yellow, 1000V/32A CAT II
SO5148-1LSet of safety measurement cables, 4mm (31 leads)
SO5126-8BSafety measurement cable 4mm, 25cm/10", black, 600V CAT III ~1000V CAT II / 32A
SO5126-8LSafety measurement cable 4mm, 50cm/20", black, 600V CAT III ~1000V CAT II / 32A

Learning Content in Detail

Students investigate the operating behavior of a transmission line through measurement: determining parameters, investigating limiting cases and assessing losses.

Determining line parameters

Students measure the resistances, inductances and capacitances of the transmission line.

Investigating the line under no-load conditions

Students analyze the Ferranti effect and calculate the capacitive charging current.

Evaluating the line under matched-load conditions

Students determine the surge impedance loading by terminating the line with its characteristic impedance.

Recording short-circuit behavior

Students measure short-circuit currents and evaluate the behavior during three-phase short circuits.

Analyzing mixed loads

Students investigate the power flow with resistive-inductive loads and the resulting voltage drops.

Sizing reactive power compensation

Students design compensation circuits and check how much they reduce transmission losses.

Features & Applications

The experiments address the key issues of grid operation: power transmission on high-voltage lines in the interconnected grid, transmission losses and efficiency, and reactive power compensation for optimizing grids.
  • Realistic line model — The equipment set replicates a 380 kV overhead line at a voltage and current scale of 1:1000.
  • Automatic length switching — Students place the appropriate overlay mask on the module and thereby switch the line length directly between 150 km and 300 km.
  • Comprehensive load analyses — The operating behavior can be investigated with a mixed resistive-inductive load as well as in the special cases of no load, matched load and short circuit.
  • Integrated PC-based data acquisition — Networkable Power Quality Meters with SCADA connectivity transfer the measured values to the PC for visualization.
  • Three-phase line module (CO3301-3A) — The module contains lumped elements for resistance, inductance, and line-to-line and line-to-ground capacitance, providing an accurate model of the line.
  • Load modules up to 1 kW — Three separate modules for resistive, inductive and capacitive loads allow wye, delta, series and parallel connections.
  • Power Quality Meter (CO5127-1S) — The Ethernet-enabled meter records currents, voltages, line harmonics and distortion factors and shows them on a large graphic display.
  • Circuit breaker module (CO3301-5P) — It switches the 400 V supply voltage on and off during the experiments, either manually or by electrical remote control.
  • SCADA for PowerLab — The viewer software visualizes the power grid in real time, logs the measured values and makes them available for evaluation.
Learners working with RXLea on a tablet at a Lucas-Nuelle training system
RXLea

From Knowledge Comes Capability.

You guide the learning

Where theory and practice go hand in hand.

RXLea brings a new way of learning: project-based, hands-on and clearly structured. Learners solve real-world tasks, while instructors save time on preparation. Interactive modules, smart analytics and real hardware create a modern, efficient learning world.

Hands-on and interactive

Animations, interactive tasks and realistic scenarios build a deep understanding. All content is organized into clear learning paths for focused, hands-on learning.

Digital support

3D assembly animations and digital instructions simplify complex procedures, reduce errors and help learners work more independently.

Visual support

Overview graphics, screenshots and sample animations make the learning world transparent. Photos from the learning packages are also available, including country-specific versions where needed.

Learners using a tablet at an energy training system
RXLea on desktop, laptop and tablet
RXLea Path Creator for building learning journeys
RXLea Navigator showing the learning world
Learn more about RXLea
Newsletter

Stay ahead in
technical training.

Get the latest training systems, product launches and educational insights, delivered directly to your inbox.

Your email address

By subscribing, you agree to our Privacy Policy. You can unsubscribe at any time.

 Please select at least one category before subscribing.
I'm interested in - select all that apply