Skip to content

HV Systems and HV Air Conditioning in Electric Vehicles

RXLea
Digital projects for hands-on learningInteractive learning content, directly connected to the training system.

HV Systems and HV Air Conditioning in Electric Vehicles

AAC21CT

Teach sound diagnostic skills on high-voltage drives and real vehicle air conditioning systems. The brand-independent training system combines intrinsic safety systems with hands-on refrigeration technology.

Learning Content
  • De-energizing HV systems
  • Verifying the absence of voltage
  • Analyzing bus communication
  • Locating insulation faults
KEY FEATURES
  • Integrated fault insertion
  • Safe bus signal measurement
  • Contactless measurement technology
  • Dynamic motor operation
Speak with a Product Specialist +1 (757) 808-5696 · sales@lucas-nuelle.com

Prepare your learners optimally for the diagnosis, maintenance and servicing of electric and hybrid vehicles. This system is based on the physical coupling of a three-phase high-voltage drive with a real, fully functional vapor-compression refrigeration system. Automotive service shops need an in-depth understanding of integrated cooling circuits in order to avert life-threatening risks. Through contactless measurements on real components, participants acquire sound practical and diagnostic skills with no risk of accidents.

CO3221-6PCarTrain "High Voltage and Air Conditioning Training System"
LM8313Insulation and Electrical Resistance Meter (Automotive)
LM8677Extended safety equipment for diagnostics on HV vehicles
LM8673Fiber Pole for High Voltage Systems
LM8588Composite Insulating Gloves, Class 0
LM8671Safety Zone for CarTrain/TruckTrain (Hybrid and EVs)
LM8660Standard Group Safety Box for Lockout/Tagout, 1 Padlock
LM8320A/C Service Unit for R134a and R1234yf
ST7200-5MProtection cover for CarTrain/InsTrain experiment trolleys
ST8010-4TMonitor holder for flat screen monitor of weight up to 15kg / 33lbs
SO3216-9FCarTrain 4mm safety measuring leads set for CO3221-6P

Learning Content in Detail

With this system, learners acquire essential skills for working safely with high-voltage systems and air conditioning systems in electric vehicles.

De-energizing HV systems

Learners disconnect the service disconnect plug in accordance with the manufacturer’s specifications.

Verifying the absence of voltage

Learners test the high-voltage system safely with a two-pole voltage tester.

Analyzing bus communication

Learners record CAN and LIN signals from the air conditioning components with the oscilloscope.

Locating insulation faults

Learners evaluate the pulsed square-wave signal of the integrated insulation monitoring device.

Evaluating intrinsic safety

Learners test the automatic disconnection of the high-current contactors via the pilot line.

Assessing the refrigerant circuit

Learners check the function of the thermostatic expansion valve in the system.

Thermal relationships

Learners measure the temperature-dependent voltage drop across the NTC sensors.

Features & Applications

Discover the versatile functions of this training system for hands-on teaching of high-voltage systems and vehicle air conditioning systems.
  • Integrated fault insertion — The system offers 14 switchable faults in the high-voltage and air conditioning circuits. Learners diagnose malfunctions in a practical way using real circuit diagrams and shop equipment.
  • Safe bus signal measurement — Learners pick up CAN and LIN signals directly from touch-proof 4 mm jacks. They analyze the networked communication live with the oscilloscope.
  • Contactless measurement technology — The system allows contactless analyses directly on the electric motor. This gives learners optimum protection against accidents in class and maximizes safety.
  • Dynamic motor operation — Learners control load changes using virtual sliders. They investigate the starting behavior of the electric motor and the synchronous rotating field in real time.
  • De-energizing in accordance with DGUV — The system replicates the real decommissioning process. Learners remove safety components and verify the absence of voltage by measurement.
  • Scroll compressor with electric motor — The high-voltage air conditioning compressor circulates the refrigerant and raises its pressure. The non-conductive POE oil protects insulated windings against short circuits to the housing.
  • Insulation monitor & LED — The IMD module continuously monitors the insulation level of the IT system. It generates measuring voltages and signals faults immediately via a warning lamp.
  • Wired pilot line — The interlock loop connects all high-voltage components. If a connector is disconnected, the system immediately trips the high-current contactors for protection.
  • Condenser with filter — The aluminum condenser cools hot refrigerant gas. The built-in filter medium actively removes dirt and moisture from the refrigerant circuit.
  • Coaxial-line heat exchanger — The refrigerant line carries hot and cold fluid in physically separate counterflow paths. It pre-cools the liquid medium for higher cooling capacity.
  • Thermostatic valve — The expansion valve regulates the quantity injected into the evaporator as a function of temperature. It precisely separates the high-pressure circuit from the low-pressure circuit.
  • Space Vector Control — The module visualizes the rotating stator magnetic field in a vector diagram. Learners compare the effect of different modulation methods on motor operation.
Learners working with RXLea on a tablet at a Lucas-Nuelle training system
RXLea

From Knowledge Comes Capability.

You guide the learning

Where theory and practice go hand in hand.

RXLea brings a new way of learning: project-based, hands-on and clearly structured. Learners solve real-world tasks, while instructors save time on preparation. Interactive modules, smart analytics and real hardware create a modern, efficient learning world.

Hands-on and interactive

Animations, interactive tasks and realistic scenarios build a deep understanding. All content is organized into clear learning paths for focused, hands-on learning.

Digital support

3D assembly animations and digital instructions simplify complex procedures, reduce errors and help learners work more independently.

Visual support

Overview graphics, screenshots and sample animations make the learning world transparent. Photos from the learning packages are also available, including country-specific versions where needed.

Learners using a tablet at an energy training system
RXLea on desktop, laptop and tablet
RXLea Path Creator for building learning journeys
RXLea Navigator showing the learning world
Learn more about RXLea
Newsletter

Stay ahead in
technical training.

Get the latest training systems, product launches and educational insights, delivered directly to your inbox.

Your email address

By subscribing, you agree to our Privacy Policy. You can unsubscribe at any time.

 Please select at least one category before subscribing.