LOTO Trainer for HV Vehicles
LOTO Trainer for HV Vehicles
Hands-on training in safely de-energizing and re-energizing EV high voltage systems. Students practice LOTO, absence-of-voltage verification and fault diagnosis. Supports key ASE xEV Level 1 and 2, as well as ASE L3 safety competencies.
- Safely isolate and re-energize EV high voltage systems
- Apply Lock Out/Tag Out (LOTO) procedures and verify absence of voltage
- Perform Live-Dead-Live testing at high voltage measurement points
- Diagnose and prepare for high voltage system faults using realistic service scenarios
- De-energizing high voltage systems using all standard workshop methods
- Integrated Fault Switching
- Maximum Safety Assured
- Integrated Lockable Security Box
This training system provides structured, hands-on instruction in Loto Trainer. Learners develop skills in Apply concepts from Loto Trainer, Apply concepts from Loto Trainer and Investigate measurement and testing. Practical work includes Hands-on application of Loto Trainer, measurement and testing.
Downloads
| Base Product | |
| CX3226-1A7 | LOTO Trainer for HV Vehicles (Fault Simulator included) |
| Measuring Instruments | |
| LM8334 | Digital-Milliohmmeter |
| LM8335 | Digital Insulation Tester, 125/250/500/1000 V/4000 MΩ |
| LM8302 | Two-pole voltage tester, 12-690V/AC/DC, CAT III 690V, CAT IV 600V |
| Accessories | |
| LM8588 | Composite Insulating Gloves, Class 0 |
| LM8660 | Standard Group Safety Box for Lockout/Tagout, 1 Padlock |
Learning Content in Detail
With the “Hochvolt-Frischalttrainer” training system, learners develop practical, job-relevant skills. Key topics include Apply concepts from Hochvolt-Frischalttrainer, Apply concepts from Hochvolt-Frischalttrainer and Investigate measurement and testing.
Safely isolate and re-energize EV high voltage systems
Learners follow the correct sequence to disable and restore high-voltage systems safely.
Apply Lock Out/Tag Out (LOTO) procedures and verify absence of voltage
Learners use proper LOTO procedures, PPE, and test methods to confirm a safe working condition.
Perform Live-Dead-Live testing at high voltage measurement points
Learners verify their test equipment and confirm absence of voltage using the live-dead-live method.
Diagnose and prepare for high voltage system faults using realistic service scenarios
Learners identify and interpret faults, warning conditions, and system responses during guided diagnostic tasks.
Features & Applications
-
De-energizing high voltage systems using all standard workshop methods — Trainees safely energize high voltage and low-voltage systems across all common configurations. -
Integrated Fault Switching — Students identify and measure up to 10 errors encountered in workshop practice - Maximum Safety Assured — Trainees practice working with high-voltage systems in the safe environment of the training simulator before applying what they have learned to actual vehicles.
-
Integrated Lockable Security Box — The enclosed padlock can be used to secure the car key against unauthorized access. -
High Voltage Measurement Points for Live-Dead-Live Measurement — A cover on the inverter that can be removed with a screwdriver, with test points underneath for verifying the absence of voltage. -
Realistic Startup Procedure — With the Smart Key inserted, the system can be started using the start button. The status LEDs allow you to monitor the HV system's precharge process. -
High Voltage Battery — A dedicated service maintenance connector disconnects the HV battery, while LED indicators display the status of the main contactors. -
Power Electronics with Equipotential Bonding — Trainees measure the equipotential bonding of power electronics at practical test points and evaluate the low-impedance characteristics. -
Low Voltage Disconnect Points — Trainees practice indirect disconnection methods using the low-voltage service maintenance connector, the high-voltage fuse, and tester-guided disconnection. -
User Interface — Trainees operate the integrated diagnostic tester, fault switch, and system settings directly via the built-in control display. -
12 Volt System — Students observe the voltage of the 12V vehicle electrical system under various operating conditions, including fault conditions.

From Knowledge Comes Capability.
You guide the learning
Where theory and practice go hand in hand.
RXLea brings a new way of learning: project-based, hands-on and clearly structured. Learners solve real-world tasks, while instructors save time on preparation. Interactive modules, smart analytics and real hardware create a modern, efficient learning world.
Hands-on and interactive
Animations, interactive tasks and realistic scenarios build a deep understanding. All content is organized into clear learning paths for focused, hands-on learning.
Digital support
3D assembly animations and digital instructions simplify complex procedures, reduce errors and help learners work more independently.
Visual support
Overview graphics, screenshots and sample animations make the learning world transparent. Photos from the learning packages are also available, including country-specific versions where needed.




Stay ahead in
technical training.
Get the latest training systems, product launches and educational insights, delivered directly to your inbox.