CSY01PT

Training system for functional safety to EN ISO 13849-1 and EN 62061: learners assess risks, wire single-channel and dual-channel guard door controls with EMERGENCY STOP and parameterize the 3SK2122 safety relay.

Learning Content
  • Applying the Machinery Directive
  • Determining SIL and PL levels
  • Building single-channel circuits
  • Implementing dual-channel safety structures
KEY FEATURES
  • Standards-compliant risk assessment
  • SIL 1 and SIL 3 circuits compared directly
  • 3SK2122 programmable safety relay
  • Integrated guard door with guard locking
Speak with a Product Specialist +1 (757) 808-5696 · sales@lucas-nuelle.com

The Machinery Directive 2006/42/EC requires consistent protective measures against moving machine parts. This is implemented through safe shutdown and interlocked guard doors, designed for the required performance level or SIL. The training system maps this chain onto A4 training boards. Learners first carry out a hazard analysis to EN ISO 12100 and derive the safety integrity level. They then wire a single-channel SIL 1 guard door control, followed by the dual-channel version up to SIL 3 with redundant position switches and contactors. Using SIRIUS Safety ES, they configure logic operations, startup tests and time-delayed guard locking. Finally, they deliberately provoke cross-circuits and welded contactor contacts and check the diagnostics.

CO3715-7GProtective gate with safety position switch
CO3715-7MSafety relay for protection monitoring
CO3715-7NProtective gate with safety position switch
CO3209-1BSwitches and buttons for contactor controls, 24 V
CO3715-7LSafety overload unit with working motor
SO2800-4DInteractive Lab Assistant: CSY 1 Safety systems with safety relays
CO3538-8CStabilised DC powersupply 24V/6A
ST7200-7ASybaPro experiment trolley, 3-level, 6 sockets, 1250x1970x800mm
ST8010-4TMonitor holder for flat screen monitor of weight up to 15kg / 33lbs
ST7200-5LProtection cover for three-level experiment trolleys
SO5148-2HSet of safety measurement cables, 4 mm (30 leads)
SO5126-3RSafety connecting plug 4mm with tap (2x), black, 1000V/32A CAT II
SO5126-3USafety connecting plug 4mm with tap (2x), red, 1000V/32A CAT II
SO5126-3VSafety connecting plug 4mm with tap (2x), blue, 1000V/32A CAT II

Learning Content in Detail

The training progresses from risk assessment according to the Machinery Directive and the construction of single-channel and dual-channel safety circuits through to the parameterization and diagnostics of the safety relays.

Applying the Machinery Directive

Learners analyze the requirements of Directive 2006/42/EC and carry out risk assessments to EN ISO 12100.

Determining SIL and PL levels

Learners determine the severity of injury, duration of exposure and possibility of avoidance, and use these to specify SIL 1 to SIL 3.

Building single-channel circuits

Learners wire a SIL 1 guard door control with automatic start as well as with manual and monitored start.

Implementing dual-channel safety structures

Learners wire two redundant position switches and contactors to meet SIL 3 requirements.

Integrating EMERGENCY STOP functions

Learners integrate dual-channel EMERGENCY STOP buttons with edge evaluation for safe acknowledgment.

Controlling a guard door with guard locking

Learners program a 5 s time-delayed unlocking function for tools that continue to run down.

Carrying out fault diagnosis

Learners provoke cross-circuits, ground faults and welded contactors and evaluate the status LEDs.

Parameterizing safety software

Learners create logic diagrams in SIRIUS Safety ES, carry out consistency checks and assign CRC codes.

Features & Applications

The system covers the tasks involved in safeguarding machinery: automation technology, machine safety and occupational safety, as well as the electrical equipment of machines.
  • Standards-compliant risk assessment — Learners carry out hazard analyses to EN ISO 12100 and systematically derive the required safety integrity levels from SIL 1 to SIL 3.
  • SIL 1 and SIL 3 circuits compared directly — The system allows single-channel and dual-channel safety architectures to be compared directly. Learners use this to verify the required risk reduction.
  • 3SK2122 programmable safety relay — Using SIRIUS Safety ES software, learners graphically configure and test complex logic operations, startup tests and time-delayed guard locking.
  • Integrated guard door with guard locking — A real guard door model with magnetic guard locking and a key switch shows how people are protected from machine parts that continue to run down.
  • Fault diagnosis and cross-circuit tests — Learners simulate wire breaks, welded contactor contacts and cross-circuits, thereby verifying automatic fault detection.
  • 3SK1122 safety relay (CO3715-7M) — Compact basic unit with DIP switches for automatic start, monitored start and cross-circuit detection up to SIL 3 and PL e.
  • 3SK2122 parameterizable safety relay (CO3715-7N) — Freely configurable safety switching device with 20 F inputs and 4 F outputs, allowing modular safety applications to be created in software.
  • Guard door mechanical board (CO3715-7G) — Replicates protective hoods with two position switches operating in opposite directions (S1/S2) and a guard-locking solenoid with auxiliary release (S3/S4).
  • Safety load contactor unit (CO3715-7L) — Contains redundant load contactors with positively driven feedback contacts and switches off the integrated function motor directly.
  • EMERGENCY STOP button and control elements (CO3209-1B) — Dual-channel EMERGENCY STOP mushroom button with twist-to-release, plus an indicator light and a reset button for manual start enabling.
  • Single-phase power connection — The module protects the workstation with a switch, a circuit breaker and a Schuko outlet.
  • Siemens SIRIUS Safety ES — Graphical engineering software for creating safety diagrams, parameterizing F inputs and F outputs, checking consistency and CRC-based release.
  • Interactive Lab Assistant course SO2800-4D — Interactive learning software with detailed circuit diagrams, fundamentals of the relevant standards, experiment instructions and automated evaluation.
Learners working with RXLea on a tablet at a Lucas-Nuelle training system
RXLea

From Knowledge Comes Capability.

You guide the learning

Where theory and practice go hand in hand.

RXLea brings a new way of learning: project-based, hands-on and clearly structured. Learners solve real-world tasks, while instructors save time on preparation. Interactive modules, smart analytics and real hardware create a modern, efficient learning world.

Hands-on and interactive

Animations, interactive tasks and realistic scenarios build a deep understanding. All content is organized into clear learning paths for focused, hands-on learning.

Digital support

3D assembly animations and digital instructions simplify complex procedures, reduce errors and help learners work more independently.

Visual support

Overview graphics, screenshots and sample animations make the learning world transparent. Photos from the learning packages are also available, including country-specific versions where needed.

Learners using a tablet at an energy training system
RXLea on desktop, laptop and tablet
RXLea Path Creator for building learning journeys
RXLea Navigator showing the learning world
Learn more about RXLea
Newsletter

Stay ahead in
technical training.

Get the latest training systems, product launches and educational insights, delivered directly to your inbox.

Your email address

By subscribing, you agree to our Privacy Policy. You can unsubscribe at any time.

 Please select at least one category before subscribing.
I'm interested in - select all that apply