Complex Loads, Power Consumption Measurement and Peak Load Monitoring
Complex Loads, Power Consumption Measurement and Peak Load Monitoring
Students analyze static and dynamic three-phase consumers, measure energy consumption, and perform manual and automatic reactive power compensation. This system provides learners with complete practical training equipment.
- Analyzing complex loads
- Carrying out and evaluating reactive power compensation
- Measuring and evaluating energy
- Commissioning dynamic loads
- Modular emulation of complex three-phase loads
- Compensating reactive power manually and automatically
- Energy monitoring and connection to the smart grid
- Intelligent power factor controller with connection detection
The efficient use of electrical energy and maintaining grid quality are central challenges for modern power grids. Reactive power caused by inductive consumers puts additional strain on these grids and must be compensated. This training system provides practical methods for analyzing complex consumers. You will learn to measure energy consumption and perform manual and automatic reactive power compensation. The system perfectly prepares you for the challenges of intelligent power grids.
| Base Product | |
| CO3208-4L7 | Lamp board 230V |
| CO3301-5C7 | Reactive power controller |
| CO3301-5J7 | Switchable Capacitor Battery |
| SE2683-1R7 | Three-phase asynchronous motor, squirrel-cage, 1 kW, 360/208 V |
| CO3212-2D | Star-Delta switch |
| CO3212-1P7 | Motor protection switch, 3 pole, 2,8-4A; US Version |
| CO3301-5P | Power switch module |
| SO2800-3Y7 | Interactive Lab Assistant: Energy management |
| CO3301-3F | Variable Ohmic load, three-phase, 1kW |
| CO3301-3E | Capacitive load, three-phase, 1kW |
| CO3301-3D | Inductive load, three-phase, 1kW |
| CO3301-5P | Power switch module |
| Power Supply | |
| CO3212-5V7 | Three-phase power supply with motor protection switch |
| Measuring Instruments | |
| CO5127-2S | Power Quality Meter mit Grafikdisplay und Langzeitspeicher |
| CO5127-2A | Power-Multimeter |
| Accessories | |
| LM9057 | Patch cable Cat5E 1x 1m yellow, 2x 2m yellow |
| LM8257 | USB 2.0 Ethernet adapter, 10/100 |
| LM9988-8 | 5-Port Ethernet Switch (International) |
| ST8010-4J8 | Multiple power outlet strip, 6 outlets, US-standard |
| CO3636-6Y7 | Servo machine test stand for 1kW machines incl. software ActiveServo (D,GB,F,E) |
| SE2662-7D | Coupling guard with LED lighting for 1kW machines |
| SE2662-6A | Rubber coupling sleeve, 1kW |
| Furniture | |
| ST8010-4G | Keyboard adapter for flat screen monitor holders |
| ST8008-8N7 | Protected power distribution for workstations |
| ST8010-4J8 | Multiple power outlet strip, 6 outlets, US-standard |
| Furniture Accessories | |
| ST8000-4C | Display for Energy Management equipment |
| Measurement Leads | |
| SO5126-3R | Safety connecting plug 4mm with tap (2x), black, 1000V/32A CAT II |
| SO5126-3V | Safety connecting plug 4mm with tap (2x), blue, 1000V/32A CAT II |
| SO5126-3W | Safety connecting plug 4mm with tap (2x), green/yellow, 1000V/32A CAT II |
| SO5148-1L | Set of safety measurement cables, 4mm (31 leads) |
| SO5148-1Z | Set of safety measurement cables, 4mm, 10m, 5 pcs, incl. fastening |
Learning Content in Detail
Analyzing complex loads
Carrying out and evaluating reactive power compensation
Measuring and evaluating energy
Commissioning dynamic loads
Features & Applications
- Modular emulation of complex three-phase loads — Resistive, inductive and capacitive components form R, L, C, RL, RC and RLC loads in wye or delta connection. Students use them to investigate balanced and unbalanced industrial and household loads and their effects on the grid.
- Compensating reactive power manually and automatically — Students analyze the reactive power demand of an induction motor, calculate the compensation capacitance and first switch the capacitor steps manually. The industrial reactive power controller then takes over load-dependent control.
- Energy monitoring and connection to the smart grid — The power quality meter records real, reactive and apparent power, power factor and harmonics and delivers the data via Ethernet to the SCADA software, where load profiles are generated as the basis for peak load management.
- Intelligent power factor controller with connection detection — The controller automatically detects the wiring and step ratings. Students use it to practice wizard-assisted commissioning and analyze the control behavior in four-quadrant operation.
- SCADA for PowerLab — The software replicates an industrial control room: monitoring the power quality meter’s measured values in real time, recording load profiles and switching states, and comparing grid and motor parameters during compensation.

From Knowledge Comes Capability.
You guide the learning
Where theory and practice go hand in hand.
RXLea brings a new way of learning: project-based, hands-on and clearly structured. Learners solve real-world tasks, while instructors save time on preparation. Interactive modules, smart analytics and real hardware create a modern, efficient learning world.
Hands-on and interactive
Animations, interactive tasks and realistic scenarios build a deep understanding. All content is organized into clear learning paths for focused, hands-on learning.
Digital support
3D assembly animations and digital instructions simplify complex procedures, reduce errors and help learners work more independently.
Visual support
Overview graphics, screenshots and sample animations make the learning world transparent. Photos from the learning packages are also available, including country-specific versions where needed.




Stay ahead in
technical training.
Get the latest training systems, product launches and educational insights, delivered directly to your inbox.