Item No.: CO3301-5S

Double busbar unit, three-phase, coupler panel

The panel comprises two busbars for operation with parallel lines. The busbars have two outgoing feeders, which can be connected or disconnected using isolators. The circuit breaker connects the two parallel lines.

Switch elements:

  • 2x Isolators, with remote switching mechanism and auxiliary contact
  • 1x Circuit breaker 5A, with remote switching mechanism and auxiliary contact

Indicators:

  • Status lamps for the isolators and the circuit breaker
  • Controlled by pushbuttons, control inputs or Ethernet

Inputs/outputs:

  • 4mm safety sockets
  • 2 Ethernet ports
  • Acoustic alarm for warning and alarm signals
  • Three-phase current measurement up to 5A
  • 3 x three-phase voltage measurement up to 500 V

Integrated monitors:

  • Over-current, over-voltage, phase angle, voltage differential
  • Control voltage: 24V
  • Dimensions: 297 x 228 x 50mm (HxWxD)
  • Weight: 2kg