RCC 11 Open- and closed-loop control

RCC 11 Open- and closed-loop control

Anyone wishing to work in refrigeration or air-conditioning needs to know all about the many electrical and control components, as well as the systems themselves. The course teaches aspects of electrical engineering, open- and closed-loop control, as well as some drive technology in a way that is practical and specific to refrigeration and air-conditioning.

Standards specifically applicable to the circuits used in construction of refrigeration systems are observed and the relevance to common practice is underpinned by using technical documentation from a variety of manufacturers.

The following training contents are covered:

  • Generating a control voltage
  • Circuits with primary and auxiliary contactors
  • Circuits with time-delay relays
  • Thermostats and pressures switches in contact control systems
  • Safety chain for refrigeration and air-conditioning control systems
Basic equipment set, consisting of:
1
Switches and buttons for contactor controls
Switches and buttons for contactor controls CO3209-1K
1
Mains feed for heating control with control transformer, type-B RCD, 1/3-pole ci
Mains feed for heating control with control transformer, type-B RCD, 1/3-pole ci CO3209-5B
1
Control unit with 3 primary contactors and auxiliary contacts
Control unit with 3 primary contactors and auxiliary contacts CO3209-5C
1
Control unit with 3 auxiliary contactors and auxiliary contacts
Control unit with 3 auxiliary contactors and auxiliary contacts CO3209-5D
1
Motor protection switches, pair, for partially wound motor, 1.8...2.5A
Motor protection switches, pair, for partially wound motor, 1.8...2.5A CO3209-6E
1
Motor protection relay with primary contactor and auxiliary contacts, 2NO/2NC
Motor protection relay with primary contactor and auxiliary contacts, 2NO/2NC CO3209-6W
1
Pick-up delayed relay
Pick-up delayed relay CO3209-5G
1
Static time-delay relay
Static time-delay relay CO3209-5H
1
Mechanical defrost timer, 2 channel
Mechanical defrost timer, 2 channel CO3209-5L
1
Room thermostat for heating and air conditioning
Room thermostat for heating and air conditioning CO3209-5N
1
High-pressure switch for heating circuit
High-pressure switch for heating circuit CO3209-5P
1
Low-pressure switch for heating circuit
Low-pressure switch for heating circuit CO3209-5Q
1
Oil differential pressure switch for oil circuit
Oil differential pressure switch for oil circuit CO3209-5R
1
Multi-function time-delay relay
Multi-function time-delay relay CO3209-5J
1
Full protection for motor, adjustable, includes additional 10K potentiometer
Full protection for motor, adjustable, includes additional 10K potentiometer CO3209-5M

Motor required for open- and closed-loop control:

1
Three-phase asynchronous motor, 0.3 kW n=1400 (400V/690V)
Three-phase asynchronous motor, 0.3 kW n=1400 (400V/690V) SE2683-1G
1
Shaft end guard, 0.3kW
Shaft end guard, 0.3kW SE2662-2C
Media:
1
Interactive Lab Assistant: Closed-loop control of cycles in refrigeration and air-conditioning systems
Interactive Lab Assistant: Closed-loop control of cycles in refrigeration and air-conditioning systems SO2801-1A
Accessories:
1
Set of safety measurement cables, 4mm (88 leads)
Set of safety measurement cables, 4mm (88 leads) SO5148-1C
15
Safety connecting plug 4mm with tap (2x), gr/ye, 1000V/32A CAT II
Safety connecting plug 4mm with tap (2x), gr/ye, 1000V/32A CAT II SO5126-3W
1
SybaPro experiment trolley, 3-level, 6 sockets, 1250x1970x800mm
SybaPro experiment trolley, 3-level, 6 sockets, 1250x1970x800mm ST7200-7A
Additionally recommended:
1
Wall or aluminium profile mounting storage (grey) for 48 x 4mm cables
Wall or aluminium profile mounting storage (grey) for 48 x 4mm cables ST8003-8E
1
Monitor holder for flat screen monitor of weight up to 15kg/33lbs
Monitor holder for flat screen monitor of weight up to 15kg/33lbs ST8010-4T
1
Protection cover for three-level experiment trolleys
Protection cover for three-level experiment trolleys ST7200-5L