Home/Training Systems/Manufacturing and Testing Standards
Quality and compliance
Manufacturing and Testing Standards
Our training systems are developed and manufactured in Kerpen, Germany. These are the regulations, directives and standards we design, produce and test to.
At a glance
One topic, two markets
Select a topic to see which North American standard and which European directive we design, produce and test to.
North America
UL Standards / NRTL Certification (UL, ETL, CSA)
European Union
Low Voltage Directive 2014/35/EU
North America
OSHA, ANSI B11, NFPA 79
European Union
Machinery Regulation (EU) 2023/1230
North America
FCC Rules (Part 15, 22, 24, 27)
European Union
RED 2014/53/EU
North America
TSCA (Toxic Substances Control Act)
European Union
RoHS Directive 2011/65/EU and REACH Regulation (EC) No 1907/2006
North America
FCC Part 15
European Union
EMC Directive 2014/30/EU
North America
Standards and regulations
Standards and regulations relevant to our training systems in the North American market, grouped by topic.
| Standard / Regulation | Topic |
|---|---|
| UL Standards / NRTL Certification (UL, ETL, CSA) | Electrical Safety |
| FCC Part 15 | Electromagnetic Compatibility |
| FCC Rules (Part 15, 22, 24, 27) | Radio Equipment |
| TSCA (Toxic Substances Control Act) | Chemical Regulations |
| OSHA, ANSI B11, NFPA 79 | Machinery Safety |
Low Voltage Directive 2014/35/EU
Electrical Safety (LVD)
Conformity with the essential safety requirements of the Low Voltage Directive
Electrical Hazards
Hazards that can cause injury to persons or damage to property.
Electric shock
Danger from impermissibly high touch voltages on live parts.
Touch voltage
Danger from voltages on accessible conductive parts.
Insulation failure
Danger from failure of insulation and creepage/clearance distances.
Short circuit
Danger from excessive currents caused by short circuits.
Protective Measures
Measures to prevent electrical hazards and ensure safe operation.
Protective insulation
Double or reinforced insulation prevents access to hazardous voltages.
Protective grounding
Fault currents are safely discharged to ground and hazardous voltages are limited.
Contact protection
Covers or barriers prevent access to hazardous live parts.
Safe design
Mechanically robust, fault-avoiding design and selection of safe components.
Goal
Protection of persons and property
The device must not endanger persons through electric shock or cause damage to property.
Goal
Safe operation of the device
The device is designed and manufactured to ensure safe operation under intended conditions.
Machinery Regulation (EU) 2023/1230
Machinery Safety & Risk Reduction
Conformity with the essential health and safety requirements of the Machinery Regulation
Hazards
Mechanical hazards
Moving parts, rotating elements and workpieces.
Crushing and shearing points
Risk of body parts being drawn in, crushed or sheared.
Unexpected start-up
Risk of uncontrolled start-up after standstill or when power is restored.
Electrical hazards
Risk from electric shock, arcing and electrical faults.
Control system malfunctions
Risk from software errors, sensor failures or communication problems.
Protective Measures
Risk assessment
Systematic identification and evaluation of all hazards according to EN ISO 12100.
Protective guards
Separation of danger zones and protection against access to moving parts.
Emergency stop function
Rapid stopping of the machine to prevent hazards (EN ISO 13850).
Safety-related control (PL/SIL)
Reliable safety-related control according to EN ISO 13849-1 or EN IEC 62061.
Operating instructions & warnings
Clear instructions, warnings and safety signs according to EN ISO 20607.
Goal
Protection of persons
Minimizing risks and preventing injuries and damage to health through safe design and protective measures.
Goal
Safe machine operation
Safe operation throughout the entire machine life cycle, from planning to decommissioning.
RED 2014/53/EU
Radio Equipment Directive
Conformity with the essential requirements (Article 3 of the RED)
Article 3.1(a)
Health & Safety
Protection of the health and safety of persons and animals
Electrical safety of the device
Article 3.2
Efficient Use of the Radio Spectrum
Efficient use of and access to the radio spectrum
Compliance with technical parameters
Avoidance of interference and protection of other services
Article 3.1(b)
Electromagnetic Compatibility (EMC)
Immunity
The device operates reliably despite interference from its environment.
Emission
The device does not emit impermissible interference into its environment.
Article 3.3
Cybersecurity
Protection against unauthorized access (protection of confidentiality)
Protection of network and data integrity
Protection against fraud and misuse
RoHS & REACH Compliance
Material and Chemical Compliance
Conformity with the requirements of the RoHS Directive 2011/65/EU and the REACH Regulation (EC) No 1907/2006
RoHS Directive 2011/65/EU
Restriction of Hazardous Substances
Restricts the use of certain hazardous substances in electrical and electronic equipment.
- Pb
Lead (Pb)
Restricted use
- Hg
Mercury (Hg)
Restricted use
- Cd
Cadmium (Cd)
Restricted use
- Cr6+
Hexavalent chromium (Cr VI)
Restricted use
PBB / PBDE
Restricted use
Material compliance
Verified by material declarations
REACH Regulation (EC) No 1907/2006
Chemical Compliance
Registration, Evaluation, Authorization and Restriction of Chemicals in the EU.
SVHC
Substances of very high concern
Candidate List
Regularly updated list
SCIP notifications
Database for articles
Article 33
Duty to communicate information on SVHC > 0.1% in articles
Supplier management
Supplier inquiries and evidence of compliance
Goal (RoHS)
Avoidance of hazardous substances
Reducing hazardous substances in electrical and electronic equipment to protect people and the environment.
Goal (REACH)
Transparency in the supply chain
Ensuring responsible handling of chemicals to protect people and the environment.
EMC Directive 2014/30/EU
Electromagnetic Compatibility (EMC)
Conformity with the essential requirements of the EMC Directive
Immunity
The device operates reliably despite interference from its environment.
Radio-frequency interference (RF fields)
Electrostatic discharge (ESD)
Burst / fast transient disturbances
Conducted disturbances
Emission
The device does not emit impermissible interference into its environment.
Radiated emissions
Narrowband emissions
Conducted emissions
Harmonics and flicker
Goal
Ensure immunity
The device remains stable and performs its function even when interference is present.
Goal
Limit emissions
The device only emits permissible interference and can coexist with other devices.
Questions about compliance?
Need details for a specific product?
Our team can tell you which standards and certifications apply to the training system you are planning for your institution.